Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Utah State University

Journal Articles

Engineering

2017

Articles 1 - 1 of 1

Full-Text Articles in Physical Sciences and Mathematics

An Enhanced Operational Definition Of Dielectric Breakdown For Dc Voltage Step-Up Tests, Allen Andersen, Jr Dennison Oct 2017

An Enhanced Operational Definition Of Dielectric Breakdown For Dc Voltage Step-Up Tests, Allen Andersen, Jr Dennison

Journal Articles

The imprecise definition of breakdown in the ASTM D3755-14 standard can misidentify breakdown. If the recommended test circuit current sensing element threshold is set too high, breakdown may occur undetected. Conversely, false positives may result from designating a low current threshold. An operational definition of breakdown much less sensitive to these pitfalls is outlined herein. This enhanced definition of breakdown is based on the average rate of change of the leakage current with increasing voltage, rather than a simple current threshold, avoiding ambiguous association with anomalies in current traces. For tests that continuously monitor leakage current, breakdown can be detected …