Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

TÜBİTAK

Turkish Journal of Chemistry

Journal

2016

Electrothermal atomic absorption spectrometry

Articles 1 - 3 of 3

Full-Text Articles in Physical Sciences and Mathematics

Determination Of Hexavalent Chromium In Aqueous And Alkaline Soil Extracts, Tsvetomil Voyslavov, Stefan Tsakovski, Sonya Ganeva Jan 2016

Determination Of Hexavalent Chromium In Aqueous And Alkaline Soil Extracts, Tsvetomil Voyslavov, Stefan Tsakovski, Sonya Ganeva

Turkish Journal of Chemistry

A fast, simple, and reliable method for determination of hexavalent chromium species in soil aqueous and alkaline extracts has been developed. The procedure is based on the ion-pair extraction of Cr(VI) with methyltrioctylammonium chloride (Aliquat 336) into xylene. The extract is analyzed by flame (FAAS) or electrothermal atomic absorption spectrometry (ETAAS). The method allows the detection of up to 2 mg kg$^{-1}$ Cr(VI) by FAAS and up to 25 $\mu $g kg$^{-1}$ Cr(VI) by ETAAS. The relative standard deviation varied in the range 2%-12% depending on the Cr(VI) levels in the samples. The analysis of certified reference material CRM041-30G Chromium …


Solidified Floating Organic Drop Microextraction For Speciation Of Se (Iv) And Se (Vi) In Water Samples Prior To Electrothermal Atomic Absorption Spectrometric Detection, Demi̇rhan Çitak, Mustafa Tüzen Jan 2016

Solidified Floating Organic Drop Microextraction For Speciation Of Se (Iv) And Se (Vi) In Water Samples Prior To Electrothermal Atomic Absorption Spectrometric Detection, Demi̇rhan Çitak, Mustafa Tüzen

Turkish Journal of Chemistry

A simple and fast solidified floating organic drop microextraction (SFODME) method is suggested for the speciation of Se (IV) and Se (VI) in water samples prior to electrothermal atomic absorption spectrometric (ETAAS) detection. For that purpose, 1-phenylthiosemicarbazide (PTC) was used as chelating agent and undecanol was used as extraction solvent. The pH of solution, extraction solvent volume, amount of ligand, effect of time for complex formation, and effect of possible foreign ions were also evaluated for quantitative and effective extraction of analyte. Under optimized parameters, detection limit (0.19 $\mu $g L$^{-1})$, limit of quantification (0.60 $\mu $g L$^{-1})$, relative standard …


Speciation Of Inorganic Selenium By Solid Phase Extraction Using Nanozirconium Oxide/Boron Oxide Composite Material, Hakan Erdoğan, Özcan Yalçinkaya, Ali̇ Rehber Türker Jan 2016

Speciation Of Inorganic Selenium By Solid Phase Extraction Using Nanozirconium Oxide/Boron Oxide Composite Material, Hakan Erdoğan, Özcan Yalçinkaya, Ali̇ Rehber Türker

Turkish Journal of Chemistry

The speciation and preconcentration of selenium were carried out by solid phase extraction using nanozirconium oxide/boron oxide (ZrO$_{2}$/B$_{2}$O$_{3})$. Electrothermal atomic absorption spectrometry (ETAAS) was used for detection. This preconcentration and/or speciation method depends on the retention of Se(IV) ions selectively as its ammonium pyrrolidine dithiocarbamate (APDC) complex on the sorbent. The effects of pH, flow rate, and volume of sample solution and eluent type were investigated for determining the optimum preconcentration and speciation conditions. The effects of other ions that may interfere with the determination and speciation of selenium were also investigated. Moreover, the analytical performance criteria of the method …