Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

99mtc-Hexamethylpropyleneamine Oxime Imaging For Early Detection Of Acute Lung Injury In Rats Exposed To Hyperoxia Or Lipopolysaccharide Treatment, Said H. Audi, Anne V. Clough, Steven T. Haworth, Meetha Medhora, Mahsa Ranji, John C. Densmore, Elizabeth R. Jacobs Oct 2016

99mtc-Hexamethylpropyleneamine Oxime Imaging For Early Detection Of Acute Lung Injury In Rats Exposed To Hyperoxia Or Lipopolysaccharide Treatment, Said H. Audi, Anne V. Clough, Steven T. Haworth, Meetha Medhora, Mahsa Ranji, John C. Densmore, Elizabeth R. Jacobs

Biomedical Engineering Faculty Research and Publications

99mTc-Hexamethylpropyleneamine oxime (HMPAO) is a clinical single-photon emission computed tomography biomarker of tissue oxidoreductive state. Our objective was to investigate whether HMPAO lung uptake can serve as a preclinical marker of lung injury in two well-established rat models of human acute lung injury (ALI).

Rats were exposed to >95% O2 (hyperoxia) or treated with intratracheal lipopolysaccharide (LPS), with first endpoints obtained 24 h later. HMPAO was administered intravenously before and after treatment with the glutathione-depleting agent diethyl maleate (DEM), scintigraphy images were acquired, and HMPAO lung uptake was quantified from the images. We also measured breathing rates, heart …


Region-Of-Interest Material Decomposition From Truncated Energy-Resolved Ct, Taly Gilat Schmidt Oct 2011

Region-Of-Interest Material Decomposition From Truncated Energy-Resolved Ct, Taly Gilat Schmidt

Biomedical Engineering Faculty Research and Publications

Purpose: Energy-resolved CT using photon-counting detectors has the potential to provide improved material decomposition compared to dual-kVp approaches. However, available photon-counting detectors are susceptible to pulse-pileup artifacts, especially at the periphery of the field of view (FOV) where the object attenuation is low compared to the center of the FOV. Pulse pileup may be avoided by imaging a region-of-interest (ROI) where the dynamic range is expected to be limited. This work investigated performing material decomposition and reconstructing ROI basis images from truncated energy-resolved data.

Methods: A method is proposed to reconstructimages of basis functions primarily contained within the ROI, such …