Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 15 of 15

Full-Text Articles in Physical Sciences and Mathematics

Fabrication, Characterization, Optimization And Application Development Of Novel Thin-Layer Chromatography Plates, Supriya Singh Kanyal Dec 2014

Fabrication, Characterization, Optimization And Application Development Of Novel Thin-Layer Chromatography Plates, Supriya Singh Kanyal

Theses and Dissertations

This dissertation describes advances in the microfabrication of thin layer chromatography (TLC) plates. These plates are prepared by the patterning of carbon nanotube (CNT) forests on substrates, followed by their infiltration with an inorganic material. This document is divided into ten sections or chapters. Chapter 1 reviews the basics of conventional TLC technology. This technology has not changed substantially in decades. This chapter also mentions some of the downsides of the conventional approach, which include unwanted interactions of the binder in the plates with the analytes, relatively slow development times, and only moderately high efficiencies. Chapter 2 focuses primarily on …


Chaperone-Mediated Folding And Assembly Of Β-Propeller Proteins Into Cellular Signaling Complexes, Rebecca L. Plimpton Dec 2014

Chaperone-Mediated Folding And Assembly Of Β-Propeller Proteins Into Cellular Signaling Complexes, Rebecca L. Plimpton

Theses and Dissertations

G protein signaling depends on the ability of the individual subunits of the G protein heterotrimer to assemble into a functional complex. Formation of the G protein βγ (Gβγ) dimer is particularly challenging because it is an obligate dimer in which the individual subunits are unstable on their own. Recent studies have revealed an intricate chaperone system that brings the Gβ and Gγ subunits together. This system includes the cytosolic chaperonin containing TCP-1 (CCT) and a co-chaperone phosducin-like protein 1 (PhLP1). Two key intermediates in the Gβγ assembly process, the Gβ-CCT and the PhLP1-Gβ-CCT complexes, were isolated and their structures …


Synthesis And Characterization Of Complex Molecular Assemblies On Surfaces, Nitesh Madaan Dec 2014

Synthesis And Characterization Of Complex Molecular Assemblies On Surfaces, Nitesh Madaan

Theses and Dissertations

The research presented in this dissertation is focused on the construction of complex molecular structures on planar gold and silicon dioxide surfaces using a variety of surface modification techniques, along with thorough surface characterization at each modification step. The dissertation is structured into six separate chapters. In Chapter 1, an introduction to the importance and implications of molecular level surface modification, commonly employed surface modification methods, and available surface characterization techniques is presented. Chapter 2 shows applications of novel methodologies for the functionalization of gold surfaces using alkane dithiol self-assembled monolayers and thiol-ene click chemistry. The resulting functionalized gold substrates …


Microchip Thermal Gradient Gas Chromatography, Anzi Wang Dec 2014

Microchip Thermal Gradient Gas Chromatography, Anzi Wang

Theses and Dissertations

Although the airbath oven is a reliable heating method for gas chromatography (GC), resistive heating is needed for higher analytical throughput and on-site chemical analysis because of size, heating rate and power requirements. In the last thirty years, a variety of resistive heating methods were developed and implemented for both benchtop and portable GC systems. Although fast heating rates and low power consumption have been achieved, losses in column efficiency and resolution, complex construction processes and difficulties experienced in recovering damaged columns have also become problematic for routine use of resistively heated columns. To solve these problems, a new resistively …


Ion Structure And Energetics In The Gas Phase Characterized Using Fourier Transfom Ion Cyclotron Resonance Mass Spectrometry, Chad A. Jones Sep 2014

Ion Structure And Energetics In The Gas Phase Characterized Using Fourier Transfom Ion Cyclotron Resonance Mass Spectrometry, Chad A. Jones

Theses and Dissertations

In this dissertation, I use Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) to study the structure and energetics of gas phase ions. Infrared multiphoton dissociation spectroscopy (IRMPD) is a technique for measuring the IR spectrum of gas phase ions in a Penning trap. I use this technique to investigate the conformation of cucurbituril complexes, terminal diamines, and protonated amino acids. Cross sectional areas by Fourier transform ion cyclotron resonance mass spectrometry (CRAFTI) is a technique developed by the Dearden lab to measure the cross section of gas phase ions. In this work, I further develop a fundamental understanding of …


Simple, Label-Free And Non-Instrumented Analyte Quantitation By Flow Distance Measurement In Microfluidic Devices, Debolina Chatterjee Aug 2014

Simple, Label-Free And Non-Instrumented Analyte Quantitation By Flow Distance Measurement In Microfluidic Devices, Debolina Chatterjee

Theses and Dissertations

Rapid determination of the concentrations of molecules related to diseases can provide timely information for treatment options. However, most biomarker quantitation methods require costly and complex equipment. On the other hand, point-of-care systems have less complex instrumentation needs than laboratory-based equipment, but often provide less information; for example, biomarker presence or absence instead of concentration. A complete analysis setup addressing key limitations of both laboratory-based and portable systems is highly desirable. I developed microfluidic devices with visual inspection readout of a target’s concentration from microliter volumes of solution flowed into a microchannel. Microchannels are formed within polydimethylsiloxane (PDMS), and the …


Synthesis Of 4'-Ester Resveratrol Analogues, Chromium Trioxide Oxidation Of Terpenes, And Synthesis Of Mimics Of (-)-Englerin A, Mark Jeffrey Acerson Aug 2014

Synthesis Of 4'-Ester Resveratrol Analogues, Chromium Trioxide Oxidation Of Terpenes, And Synthesis Of Mimics Of (-)-Englerin A, Mark Jeffrey Acerson

Theses and Dissertations

4’ -ester analogues of resveratrol were synthesized using reaction conditions developed to produce mono-ester products in the presence of two other unprotected phenols. Basic conditions were employed to deprotonate the most acidic 4’ phenol followed by addition of anhydrides or acid chlorides to give the ester product. The reaction favored 4’-ester formation in polar aprotic solvents with DMSO being the optimal solvent.

(—)-Englerin A is a guaiane-type sesquiterpene containing two ester side chains. Mimics of (—)-englerin A were proposed that retained the ester side chains while replacing the non-polar core with less complicated structures. These proposed mimic cores would maintain …


High-Performance Polymer Monoliths For Capillary Liquid Chromatography, Pankaj Aggarwal Jul 2014

High-Performance Polymer Monoliths For Capillary Liquid Chromatography, Pankaj Aggarwal

Theses and Dissertations

This dissertation focuses on improving the chromatographic efficiency of polymeric organic monoliths by characterizing and optimizing the bed morphology. In-situ characterization techniques such as capillary flow porometry (CFP), 3-dimensional scanning electron microscopy (3D SEM) and conductivity measurements were developed and implemented to quantitatively characterize the morphology of poly(ethylene glycol) diacrylate (PEGDA) monoliths. The CFP measurements for monoliths prepared by the same procedure in capillaries with different diameters (i.e., 75, 150, and 250 μm) clearly showed a change in average through-pore size with capillary diameter, thus, certifying the need for in-situ measurement techniques. Serial sectioning and imaging of PEGDA monoliths using …


Bioinformatic Solutions To Complex Problems In Mass Spectrometry Based Analysis Of Biomolecules, Ryan M. Taylor Jul 2014

Bioinformatic Solutions To Complex Problems In Mass Spectrometry Based Analysis Of Biomolecules, Ryan M. Taylor

Theses and Dissertations

Biological research has benefitted greatly from the advent of omic methods. For many biomolecules, mass spectrometry (MS) methods are most widely employed due to the sensitivity which allows low quantities of sample and the speed which allows analysis of complex samples. Improvements in instrument and sample preparation techniques create opportunities for large scale experimentation. The complexity and volume of data produced by modern MS-omic instrumentation challenges biological interpretation, while the complexity of the instrumentation, sample noise, and complexity of data analysis present difficulties in maintaining and ensuring data quality, validity, and relevance. We present a corpus of tools which improves …


Laser-Induced Fluorescence Imaging Of Calcium And Barium Ion Beams In The Second Vacuum Stage Of A Commercial Inductively Coupled Plasma Mass Spectrometer, Alisa Jane Edmund Jun 2014

Laser-Induced Fluorescence Imaging Of Calcium And Barium Ion Beams In The Second Vacuum Stage Of A Commercial Inductively Coupled Plasma Mass Spectrometer, Alisa Jane Edmund

Theses and Dissertations

Inductively coupled plasma-mass spectrometers (ICP-MS) have become the workhorses of many analytical labs over the past few decades. Despite the instruments' high sensitivities and low detection limits there is still a demand for improvements in several aspects of their performance. One area of improvement is in the understanding of "space charge effects" Space charge effects are classified as problems associated with the ion beam. Problems are created when the mutual repulsions of the ions make consistent focusing of the ion beam difficult. This is particularly problematic with samples containing a low concentration analyte contained within a high salt solution matrix, …


Desorption Electrospray Ionization Mass Spectrometry Imaging: Instrumentation, Optimization And Capabilities, Manan Dhunna Mar 2014

Desorption Electrospray Ionization Mass Spectrometry Imaging: Instrumentation, Optimization And Capabilities, Manan Dhunna

Theses and Dissertations

Desorption Electrospray Ionization Mass spectrometry Imaging (DESI-MSI) is an area of great interest and a promising tool in the field of chemical imaging. It is a powerful, label-free technique, which can determine, map and visualize different molecular compounds on a sample surface. The amount of information acquired in a single DESI-MSI experiment is enormous compared to other techniques, as it can simultaneously detect different compounds with their spatial distribution on the surface. The experiment can be used to produce two-dimensional and three-dimensional images. Chapter 2 focuses on the design and optimization of the setup for performing DESI-MS imaging on various …


Facile Synthesis And Characterization Of A Thermally Stable Silica-Doped Alumina With Tunable Surface Area, Porosity, And Acidity, Maryam Khosravi Mardkhe Mar 2014

Facile Synthesis And Characterization Of A Thermally Stable Silica-Doped Alumina With Tunable Surface Area, Porosity, And Acidity, Maryam Khosravi Mardkhe

Theses and Dissertations

Mesoporous γ-Al2O3 is one of the most widely used catalyst supports for commercial catalytic applications. The performance of a catalyst strongly depends on the combination of textural, chemical and physical properties of the support. Pore size is essential since each catalytic system requires a unique pore size for optimal catalyst loading, diffusion and selectivity. In addition, high surface area and large pore volume usually result in higher catalyst loading, which increases the number of catalytic reaction sites and decreases reaction time. Therefore, determination of surface area and porosity of porous supports is critical for the successful design and optimization of …


On Chip Preconcentration And Labeling Of Protein Biomarkers Using Monolithic Columns, Device Fabrication, Optimization, And Automation, Rui Yang Feb 2014

On Chip Preconcentration And Labeling Of Protein Biomarkers Using Monolithic Columns, Device Fabrication, Optimization, And Automation, Rui Yang

Theses and Dissertations

Detection of disease specific biomarkers is of great importance in diagnosis and treatment of diseases. Modern bioanalytical techniques, such as liquid chromatography with mass spectrometry (LC-MS), have the ability to identify biomarkers, but their cost and scalability are two main drawbacks. Enzyme-linked immunosorbent assay (ELISA) is another potential tool, but it works best for proteins, rather than peptide biomarkers. Recently, microfluidics has emerged as a promising technique due to its small fluid volume consumption, rapidness, low fabrication cost, portability and versatility. Therefore, it shows prominent potential in the analysis of disease specific biomarkers. In this thesis, microfluidic systems that integrate …


Polymeric Monolithic Stationary Phases For Capillary Reversed-Phase Liquid Chromatography Of Small Molecules, Kun Liu Jan 2014

Polymeric Monolithic Stationary Phases For Capillary Reversed-Phase Liquid Chromatography Of Small Molecules, Kun Liu

Theses and Dissertations

Highly cross-linked monoliths prepared from single cross-linking monomers were found to increase surface area and stability. Therefore, seven cross-linking monomers, i.e., 1,3-butanediol dimethacrylate (1,3-BDDMA), 1,4-butanediol dimethacrylate (1,4-BDDMA), neopentyl glycol dimethacrylate (NPGDMA), 1,5-pentanediol dimethacrylate (1,5-PDDMA), 1,6-hexanediol dimethacrylate (1,6-HDDMA), 1,10-decanediol dimethacrylate (1,10-DDDMA), and 1,12-dodecanediol dimethacrylate (1,12-DoDDMA), were used to synthesize highly cross-linked monolithic columns in 75-µm i.d. capillaries by one-step UV-initiated polymerization using dodecanol and methanol as porogens for reversed-phase liquid chromatography (RPLC) of small molecules. Selection of porogen type and concentration was investigated in detail. Isocratic elution of alkylbenzenes at a flow rate of 300 nL/min was conducted for all of …


Collisional Dynamic Elements Of The Pyrazine - N2o System:Middle And Low J States, La Moyne Tyler Mix Jan 2014

Collisional Dynamic Elements Of The Pyrazine - N2o System:Middle And Low J States, La Moyne Tyler Mix

Theses and Dissertations

Unimolecular reactions based on the Lindemann - Hinchelwood mechanism are important to understanding combustion and atmospheric processes. The main feature of this mechanism is the energy transfer probability distribution function, P(E',E). We have chosen to study P(E',E) through gas phase collisional dynamics probed with IR transient absorption spectroscopy. Post-collision absorption line widths for the pyrazine-N2O system are used to calculate lab frame translational temperatures. The translational temperatures reveal that collisions with large rotational energy transfer also transfer large amounts of translational energy. For J states >47 the relationship is linear indicating a constant impact parameter. Line widths for J=47 through …