Open Access. Powered by Scholars. Published by Universities.®
Physical Sciences and Mathematics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Keyword
Articles 1 - 3 of 3
Full-Text Articles in Physical Sciences and Mathematics
Curved Spacetime In The Causal Set Approach To Quantum Gravity, Ayush Dhital
Curved Spacetime In The Causal Set Approach To Quantum Gravity, Ayush Dhital
Honors Theses
Causal Set theory is an approach to quantum gravity. In this approach, the spacetime continuum is assumed to be discrete rather than continuous. The discrete points in a causal set can be seen as a continuum spacetime if they can be embedded in a manifold such that the causal structure is preserved. In this regard, a manifold can be constructed by embedding a causal set preserving causal information between the neighboring points. In this thesis, some of the fundamental properties of causal sets are discussed and the curvature and dimension information of Minkowski, de Sitter, and Anti-de Sitter spaces is …
Exploring Manifoldlike Causal Sets And Their Dimensions, Santosh Bhandari
Exploring Manifoldlike Causal Sets And Their Dimensions, Santosh Bhandari
Honors Theses
Causal Set Theory is an approach to quantum gravity that tries to replace the continuum spacetime structure of general relativity with the spacetime that has the property of discreteness and causality. From the standpoint of causal set theory, our spacetime is made up of discrete points that are causally related to one another. A causal set is said to be manifoldlike if it can be faithfully embedded in a Lorentzian manifold. In this thesis, some of the fundamental properties of causal sets are discussed. The first chapter is devoted to the historical background of quantum gravity with a discussion of …
Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina
Heel Down And Toe-Off Time Measured With Ultrasonic Doppler System And Force Plate Sensor, Sabin Timsina
Honors Theses
Collie Box is a medical device that measures the gait parameters of the person walk- ing in front of it. This device uses the Ultrasonic Doppler system to extract the heel-contact and toe-off times of a person walking within the range of 2-10 meters. These times are used to determine the leg’s swing phase and double stance times. The ultrasonic transducer of 10mm diameter is driven at 40kHz. At the time of the heel-contact and toe-off, foot velocity is zero while the torso part of the human body is still in motion. The wide directivity of 10mm diameter ultrasonic transducer …