Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Life Sciences

Selected Works

Stephen Blanksby

Detection

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Direct Detection Of Additives And Degradation Products From Polymers By Liquid Extraction Surface Analysis Employing Chip-Based Nanospray Mass Spectrometry, Martin Paine, Phillip Barker, Shane A. Maclaughlin, Todd W. Mitchell, Stephen J. Blanksby Oct 2012

Direct Detection Of Additives And Degradation Products From Polymers By Liquid Extraction Surface Analysis Employing Chip-Based Nanospray Mass Spectrometry, Martin Paine, Phillip Barker, Shane A. Maclaughlin, Todd W. Mitchell, Stephen J. Blanksby

Stephen Blanksby

Rationale: Polymer-based surface coatings in outdoor applications experience accelerated degradation due to exposure to solar radiation, oxygen and atmospheric pollutants. These deleterious agents cause undesirable changes to the polymers aesthetic and mechanical properties reducing its lifetime. The use of antioxidants such as hindered amine light stabilisers (HALS) retard these degradative processes, however, mechanisms for HALS action and polymer degradation are poorly understood. Methods: Detection of the hindered amine light stabiliser (HALS) TINUVIN®123 (bis (1-octyloxy-2,2,6,6-tetramethyl-4-piperidyl) sebacate) and the polymer degradation products directly from a polyester-based coil coating was achieved by liquid extraction surface analysis (LESA) coupled to a triple quadrupole QTRAP® …


Detection And Quantification Of Tear Phospholipids And Cholesterol In Contact Lens Deposits: The Effect Of Contact Lens Material And Lens Care Solution, Jennifer Saville, Zhenjun Zhao, Mark D.P. Willcox, Stephen J. Blanksby, Todd W. Mitchell Nov 2011

Detection And Quantification Of Tear Phospholipids And Cholesterol In Contact Lens Deposits: The Effect Of Contact Lens Material And Lens Care Solution, Jennifer Saville, Zhenjun Zhao, Mark D.P. Willcox, Stephen J. Blanksby, Todd W. Mitchell

Stephen Blanksby

PURPOSE. To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS. Lipids were extracted from tears and worn contact lenses using 2: 1 chloroform: methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS. Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 +/- 1 pmol/mu L (similar to 3.8 mu g/mL) and 6 +/- 1 pmol/mu L (similar to 4.6 …