Full-Text Articles in Physical Sciences and Mathematics

Data Management And Visualization Of X-Ray Diffraction Spectra From Thin Film Ternary Composition Spreads, I. Takeuchi, C. Long, O. Famodu, M. Murakami, Jason Hattrick-Simpers, G. Rubloff, M. Stukowski, K. Rajan Mar 2015

Data Management And Visualization Of X-Ray Diffraction Spectra From Thin Film Ternary Composition Spreads, I. Takeuchi, C. Long, O. Famodu, M. Murakami, Jason Hattrick-Simpers, G. Rubloff, M. Stukowski, K. Rajan

Jason R. Hattrick-Simpers

We discuss techniques for managing and visualizing x-ray diffraction spectrum data for thin film composition spreads which map large fractions of ternary compositional phase diagrams. An in-house x-ray microdiffractometer is used to obtain spectra from over 500 different compositions on an individual spread. The MATLAB software is used to quickly organize the data and create various plots from which one can quickly grasp different information regarding structural and phase changes across the composition spreads. Such exercises are valuable in rapidly assessing the “overall” picture of the structural evolution across phase diagrams before focusing in on specific composition regions for detailed …


Implantable Polymer/Metal Thin Film Structures For The Localized Treatment Of Cancer By Joule Heating, Nima Rahbar, Kwabena Kan-Dapaah, Christian Theriault, Wole Soboyejo Dec 2014

Implantable Polymer/Metal Thin Film Structures For The Localized Treatment Of Cancer By Joule Heating, Nima Rahbar, Kwabena Kan-Dapaah, Christian Theriault, Wole Soboyejo

Nima Rahbar

This paper presents an implantable polymer/metal alloy thin film structure for localized post-operative treatment of breast cancer. A combination of experiments and models is used to study the temperature changes due to Joule heating by patterned metallic thin films embedded in poly-dimethylsiloxane. The heat conduction within the device and the surrounding normal/cancerous breast tissue is modeled with three-dimensional finite element method (FEM). The FEM simulations are used to explore the potential effects of device geometry and Joule heating on the temperature distribution and lesion (thermal dose). The FEM model is validated using a gel model that mimics biological media. The …


Phase Imaging: Deep Or Superficial?, Nancy Burnham, O Behrend, L Odoni, J Loubet Oct 1999

Phase Imaging: Deep Or Superficial?, Nancy Burnham, O Behrend, L Odoni, J Loubet

Nancy A. Burnham

Phase images acquired while intermittently contacting a sample surface with the tip of an atomic force microscope cantilever are not easy to relate to material properties. We have simulated dynamic force curves and compared simulated with experimental results. For some cantilever–sample combinations, the interaction remains a surface effect, whereas for others, the tip penetrates the sample significantly. Height artifacts in the “topography” images, and the role of the sample stiffness, work of adhesion, damping, and topography in the cantilever response manifest themselves to different extents depending on the indentation depth.


Materials’ Properties Measurements: Choosing The Optimal Scanning Probe Microscope Configuration, Nancy Burnham, G Gremaud, A Kulik, P Gallo, F Oulevey Feb 1996

Materials’ Properties Measurements: Choosing The Optimal Scanning Probe Microscope Configuration, Nancy Burnham, G Gremaud, A Kulik, P Gallo, F Oulevey

Nancy A. Burnham

Rheological models are used to represent different scanning probe microscope configurations. The solutions for their static and dynamic behavior are found and used to analyze which scanning probe microscope configuration is best for a given application. We find that modulating the sample at high frequencies results in the best microscope behavior for measuring the stiffness of rigid materials, and that by modulating the tip at low frequencies and detecting the motion of the tip itself (not its position relative to the tip holder) should be best for studying compliant materials in liquids.


Interpretation Issues In Force Microscopy, Nancy Burnham, Richard Colton, Hubert Pollock Jun 1991

Interpretation Issues In Force Microscopy, Nancy Burnham, Richard Colton, Hubert Pollock

Nancy A. Burnham

In this paper, we will discuss force microscopy (FM) and its potential for determining mechanical properties of thin films. We will introduce the basic principles of FM, and demonstrate how FM can be used to determine materials properties as well as image surface topography, both with nanonewton or sub‐nanonewton force resolution and sub‐nanometer position resolution. As FM is still a new field, not all of the questions concerning interpretation have been fully answered. We will elucidate four current issues that must be resolved before the full potential of FM can be realized. They are: (1) the role of water vapor …