Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Physical Sciences and Mathematics

Influence Of Media Composition On The Growth Rate Of Chlorella Vulgaris And Scenedesmus Acutus Utilized For Co2 Mitigation, Czarena L. Crofcheck, Xinyi E, Aubrey Shea, Michael D. Montross, Mark Crocker, Rodney Andrews Jun 2013

Influence Of Media Composition On The Growth Rate Of Chlorella Vulgaris And Scenedesmus Acutus Utilized For Co2 Mitigation, Czarena L. Crofcheck, Xinyi E, Aubrey Shea, Michael D. Montross, Mark Crocker, Rodney Andrews

Biosystems and Agricultural Engineering Faculty Publications

Atmospheric carbon dioxide levels have increased since the industrial revolution due to increasing combustion of fossil fuels. One possible CO2 mitigation strategy is the use of microalgae for mitigation of CO2. This paper focuses on the influence of media composition on the growth rate of two microalgae strains, Chlorella vulgaris and Scenedesmus actus. A KNO3 based medium was found to work better for Chlorella, while a urea based equivalent worked better for Scenedesmus. The urea based media investigated here resulted in growth similar to that found with previously reported KNO3 based media. …


Field Calibration Of A Transient Model For Broiler Misting, Richard S. Gates, Douglas G. Overhults, Robert W. Bottcher, Shu Hui Zhang Sep 1992

Field Calibration Of A Transient Model For Broiler Misting, Richard S. Gates, Douglas G. Overhults, Robert W. Bottcher, Shu Hui Zhang

Biosystems and Agricultural Engineering Faculty Publications

A transient model to predict temperature within a tunnel ventilated broiler house during misting is developed. The model is calibrated with field data to obtain steady-state constants; transient predictions are compared to measured temperatures during cyclic misting for two different size birds. Measured temperatures during cyclic misting are shown to swing between steady-state asymptotes predicted from the model. Transient response of the model was faster than measured temperature data, in part due to temperature sensor dynamic response. The model predicts the length-wise temperature profile within the building during misting, and can be used to investigate alternate misting strategies and designs. …


Mechanical Backup Systems For Electronic Environmental Controllers, Richard S. Gates, Douglas G. Overhults, Larry W. Turner Jul 1992

Mechanical Backup Systems For Electronic Environmental Controllers, Richard S. Gates, Douglas G. Overhults, Larry W. Turner

Biosystems and Agricultural Engineering Faculty Publications

A series of mechanical backup systems for electronic environmental controllers is presented for a typical finishing swine barn and a typical tunnel ventilated broiler house. The systems consist of mechanical thermostats and timers used in parallel with the electronic controller, designed to ensure animal survival in the event of controller or related hardware failure. For swine housing, three distinct mechanical backup functions are identified; for broiler housing, four distinct mechanical backup functions are identified. Schematic diagrams of the mechanical backup functions are provided and their implementation is described.


A Survey Of Electronic Environmental Controllers, Richard S. Gates, Douglas G. Overhults, Larry W. Turner May 1992

A Survey Of Electronic Environmental Controllers, Richard S. Gates, Douglas G. Overhults, Larry W. Turner

Biosystems and Agricultural Engineering Faculty Publications

Sixteen commercially available electronic environmental controllers were evaluated. The units were classified according to enclosure type, analog versus microprocessor based control, power supply, sensors, alarms, control relays and triac output, interval timers, outside temperature feedback, and retail price. An assessment of these controllers indicated several critical limitations in the application of this technology.

The use of integrated controllers for animal production has the potential for substantial improvements in production efficiencies. If the limitations observed in the present controller technology, as represented by this sample, are addressed, industry acceptance of the technology can be accelerated. A uniform standard to address this …


Transient Overvoltage Testing Of Environmental Controllers, Richard S. Gates, Larry W. Turner, Douglas G. Overhults Mar 1992

Transient Overvoltage Testing Of Environmental Controllers, Richard S. Gates, Larry W. Turner, Douglas G. Overhults

Biosystems and Agricultural Engineering Faculty Publications

The integrated electronic control system will provide a new method for the day-to-day management of environmental control of animal production systems. No standards are currently accepted for transient overvoltage protection of these controllers. To assess the adequacy of existing designs, a test circuit was designed and used for a transient open circuit over-voltage waveform (ANSI/IEEE C62.41-1980) of 16 environmental control units: a maximum spike of 770 V was applied to the power supplies, and a spike up to 100 V was applied to temperature sensor lines. For these relatively mild tests, no failures were noted due to power supply transients, …