Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Chemistry

University of Texas Rio Grande Valley

Theses/Dissertations

Health and environmental sciences

Articles 1 - 8 of 8

Full-Text Articles in Physical Sciences and Mathematics

Removal Of Chromium(Vi) And Chromium(Iii) Ions From Aqueous Solution Using Bio-Char Generated From Agricultural Waste Products, Diego Fernando Gonzalez May 2018

Removal Of Chromium(Vi) And Chromium(Iii) Ions From Aqueous Solution Using Bio-Char Generated From Agricultural Waste Products, Diego Fernando Gonzalez

Theses and Dissertations

Heavy metals are one of the most persistent and prevalent contaminants in the aquatic environment. The removal of chromium from aqueous solution, especially in the hexavalent form is difficult. New technologies, techniques and/or new materials have been designed in order to effectively and efficiently remove chromium from the aqueous environment. The project focuses on the comparison of the effects of pH, time, temperature, binding capacity on bio-char’ generated from agricultural waste produces vs an amino modified derivative of the bio-char. Pineapple skins were dried, ground, sieved, and pyrolyzed to produce a bio-char material. The bio-char was analyzed using FTIR to …


Remediation Of Lead And Copper Ions From Water Solutions Using Transition Metal Sulfides, Jesus M. Cantu Jr. Dec 2017

Remediation Of Lead And Copper Ions From Water Solutions Using Transition Metal Sulfides, Jesus M. Cantu Jr.

Theses and Dissertations

Heavy metal contamination in water solutions has been a major concern since many transition metals don’t play a role in any biological function and are actually detrimental to human health. There have been several techniques that have been implemented for the remediation of heavy metal contaminants. For this project, three metal sulfides—Fe7S8, ZnS, TiS 2—were synthesized and studied for their capabilities to remove Pb(II) and Cu(II) from water solutions. Several parameters were investigated to determine the effects of pH, time, temperature, binding capacities, and interfering ions. The room temperature adsorption capacities ranged 6.23–333.3 mg/g for Pb(II) and 1.31–250 mg/g for …


Remediation Of Trivalent And Hexavalent Chromium Ions From Aqueous Solutions Using Titanium Dioxide Polymorphs, Yvette Cantu Dec 2017

Remediation Of Trivalent And Hexavalent Chromium Ions From Aqueous Solutions Using Titanium Dioxide Polymorphs, Yvette Cantu

Theses and Dissertations

Three titanium dioxide (TiO2) polymorphs were synthesized and used for the removal of chromium (III) and chromium (VI) from aqueous solutions. Various solution parameters were studied to determine the effects of pH, temperature, time, possible interfering ions, and capacities on the binding of Cr(III) and Cr(VI) to all three polymorphs. pH assays determined the optimum pH for the binding of both Cr(III) and Cr(VI) to each polymorph. Adsorption isotherms determined that the adsorption of Cr(III) was non-spontaneous for the three polymorphs with ΔG values ranging from 6.03 to 12.89 kJ/mol. Furthermore, the binding of Cr(VI) to anatase was also non-spontaneous …


Removal Of Cobalt And Nickel From Water Using Mno2 And Mn3o4 Nanomaterials, Maria Dolores Pacheco May 2015

Removal Of Cobalt And Nickel From Water Using Mno2 And Mn3o4 Nanomaterials, Maria Dolores Pacheco

Theses and Dissertations - UTB/UTPA

Nanomaterials MnO2 and Mn3O4 were synthesized using a titration/precipitation technique and characterized with powder XRD. A pH assay determined the optimum binding for cobalt and nickel occurred at pH 5 for both nanomaterials. A time dependency study determined that cobalt and nickel required more time with MnO2 for maximum adsorption than Mn3O4. The binding capacity study showed cobalt and nickel have good binding capacity with both nanomaterials. Interfering ion assay in the presence of Na+ , Ca2+ and Mg2+ showed minimal difference in the adsorption of cobalt and nickel to MnO2 or Mn3O4. Cobalt and nickel showed a reduction in …


Oxidation Of Dibenzothiophene To Dibenzothiophene Sulfone Using Tungsten (Vi) Oxide, Alejandrina Rivera Dec 2013

Oxidation Of Dibenzothiophene To Dibenzothiophene Sulfone Using Tungsten (Vi) Oxide, Alejandrina Rivera

Theses and Dissertations - UTB/UTPA

The oxidation of dibenzothiophene (DBT) to dibenzothiophene-sulfone has been considered as an alternate method to remove sulfur from crude oil. This study demonstrates that the oxidative desulfurization (ODS) of DBT to DBT-sulfone occurs using WO3 as a catalyst. WO3 was synthesized and characterized using X-ray diffraction to determine the phase of WO3. Each reaction was refluxed and run for four hours using WO3 as a catalyst, dibenzothiphene, and four different solvents: decahydronapthalene, n-dodecane, decalin, and dodecane. The reactions were performed at temperatures ranging from 120 oC to 150 oC. Aliquots were taken at 30 minutes for up to four hours …


Remediation Of Copper(Ii) And Lead(Ii) From Aqueous Solution Using Engineered Iron Oxide And Manganese Oxide Nanomaterials, Carlos Tamez Jr. Dec 2013

Remediation Of Copper(Ii) And Lead(Ii) From Aqueous Solution Using Engineered Iron Oxide And Manganese Oxide Nanomaterials, Carlos Tamez Jr.

Theses and Dissertations - UTB/UTPA

Nano-sized Fe3O4, Fe2O3, Mn3O4, and MnO2 were synthesized by titration/precipitation and characterized using powder XRD. pH assays determined that optimum binding occurred at pH 4 for Fe3O4 and Fe2O3 and pH 3 for Mn3O4 and MnO2. Maximum adsorption of Cu(II) and Pb(II) occurred within 20 min or less of contact with the nanomaterials. The synthesized nanomaterials showed a binding preference for Pb(II) over Cu(II) at concentrations above 50 ppm. Batch studies also showed no significant reduction in the binding of copper and lead to either Fe3O4, Fe2O3, Mn3O4, or MnO2 in the presence of Na+ , K+ , Mg2+ or …


Spectral Reflectance As An Indicator Of Foliar Concentrations Of Arsenic In Common Sunflower (Helianthus Annuus), Yuridia Patricia Peralta De Gandy Dec 2010

Spectral Reflectance As An Indicator Of Foliar Concentrations Of Arsenic In Common Sunflower (Helianthus Annuus), Yuridia Patricia Peralta De Gandy

Theses and Dissertations - UTB/UTPA

Studies were conducted to investigate the use of spectral reflectance by foliage of common sunflower as a potential indicator of arsenic contamination of soil. Germination method was developed for sunflower seeds, and cohorts of sunflower seedlings in hydroponic tanks were established. The cohorts were exposed to 0 ppm, 5 ppm, 7.5 ppm, and 10 ppm treatments of As (V) and reflectance measurements of foliage were collected using a spectroradiometer during two experiments.Results demonstrated the feasibility of using spectral reflectance by foliage of common sunflower as a potential indicator of arsenic contamination. In both experiments, arsenic concentrations in leaf tissues were …


Trace Analysis Of Volatile Organic Compounds In The Water Of The Arroyo Colorado And The Lower Laguna Madre Utilizing E.P.A.Sw846 Method 8260, Humberto Valdez May 2010

Trace Analysis Of Volatile Organic Compounds In The Water Of The Arroyo Colorado And The Lower Laguna Madre Utilizing E.P.A.Sw846 Method 8260, Humberto Valdez

Theses and Dissertations - UTB/UTPA

Volatile organic compounds (VOC) can cause a major environmental concern since they create a hazard to public health and the environment. This study focused on determining concentration of VOCs in Arroyo Colorado waters and the Lower Laguna Madre (LLM) utilizing GC/MS. Little is known on the concentration and composition of VOCs. Toluene was the most common VOC. Concentrations ranged from 0.0010 mg/L to 0.0039 mg/L. Analysis of a sediment pore water sample collected near the mouth of the Arroyo Colorado also detected toluene (0.0023 mg/L). This study showed that VOCs were concentrated near the county boat launch and somewhat downstream. …