Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Chemistry

Selected Works

Ionic self-assembly

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Physical Sciences and Mathematics

Potential Driven Deposition Of Poly(Diallyldimethylammonium Chloride) Onto The Surface Of 3-Mercaptopropionic Acid Monolayers Assembled On Gold, Wesley Sanders, Mark Anderson Nov 2008

Potential Driven Deposition Of Poly(Diallyldimethylammonium Chloride) Onto The Surface Of 3-Mercaptopropionic Acid Monolayers Assembled On Gold, Wesley Sanders, Mark Anderson

Mark R. Anderson

Electrochemical impedance spectroscopy (EIS) and quartz crystal microbalance (QCM) measurements are used to examine the ability of applied potential to drive the ionic self-assembly of poly(diallyldimethylammonium) chloride (PDDA) onto a substrate modified with a monolayer of 3-mercaptopropionic acid (3-MPA). The potential of zero charge (PZC) of the gold electrode modified with a monolayer of 3-MPA was found by differential capacitance measurements to be −0.12 (±0.01) V versus Ag−AgCl. Changing the substrate potential to values positive (−0.01 V vs Ag−AgCl) of the PZC induces interfacial conditions that are favorable for the electrostatic deposition of cationic polymers onto the surface of 3-MPA …


Modification Of A Capillary For Electrophoresis By Electrostatic Self-Assembly Of An Enzyme For Selective Determination Of The Enzyme Substrate, Stephanie Hooper, Mark Anderson Feb 2007

Modification Of A Capillary For Electrophoresis By Electrostatic Self-Assembly Of An Enzyme For Selective Determination Of The Enzyme Substrate, Stephanie Hooper, Mark Anderson

Mark R. Anderson

The integration of a separation capillary for capillary electrophoresis (CE) with an on-column enzyme reaction for selective determination of the enzyme substrate is described. Enzyme immobilization is achieved by electrostatic assembly of poly(diallydimethylammonium chloride) (PDDA) followed by adsorption of a mixture of the negatively charged enzyme glucose oxidase (GOx) and anionic poly(styrenesulfonate) (PSS). The reaction of glucose with the GOx produces hydrogen peroxide which migrates the length of the capillary and is detected amperometrically at the capillary outlet. The enzyme reaction occurs during a capillary separation, allowing selective determination of the substrate in complex samples without the need for pre- …