Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Chemistry

PDF

Graduate Theses and Dissertations

Theses/Dissertations

Microfabrication

Articles 1 - 6 of 6

Full-Text Articles in Physical Sciences and Mathematics

Thiophene Derivative Monomers Co-Electropolymerized On Microelectrodes Within Arrays For Tailored Surface Chemistry And Electrochemical Properties, Benjamin J. Jones Jul 2020

Thiophene Derivative Monomers Co-Electropolymerized On Microelectrodes Within Arrays For Tailored Surface Chemistry And Electrochemical Properties, Benjamin J. Jones

Graduate Theses and Dissertations

Potentiodynamic co-electropolymerization of two thiophene derivatives, (2,3-dihydrothieno[3,4-b]dioxin-2-yl)methanol (1) and 4-((2,3-dihydrothieno[3,4-b][1,4]dioxin-2-yl)-methoxy)-4-oxobutanoic acid (2), in aqueous solutions (0.02 M total monomer, 0.05 M sodium dodecyl sulfate (SDS) and 0.1 M LiClO4) on gold microband electrodes in an array was investigated. A modified Steglich esterification reaction between monomer 1 and succinic anhydride produced monomer 2 at 93.6% yield. Seven deposition solutions of the two monomers, defined by mol% of monomer 2 (0, 25, 34, 50, 66, 75, 100) generated seven sets of polymer films by cyclic voltammetry in a specially designed cell to conserve monomer. The onset potential for monomer oxidation and total …


Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera May 2018

Development Of Microdialysis Probes In Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization Into A Pdms Microfluidic Device, Randy Espinal Cabrera

Graduate Theses and Dissertations

A new microdialysis sampling method and microfluidic device were developed in vitro. The method consisted of using up to four microdialysis sampling probes connected in series to evaluate the relative recovery (RR) of different model solutes methyl orange, fluorescein isothiocyanate (FITC)-dextran average mol. wt. 4,000 (FITC-4), FITC-10, FITC-20, and FITC-40. Different flow rates (0.8, 1.0, and 1.5 µL/min) were used to compare experimentally observed relative recoveries with theoretical estimations. With increasing the number of probes in series, the relative recovery increases and ~100% (99.7% ± 0.9%) relative recovery for methyl orange was obtained. For larger molecules such as fluorescein isothiocyanate …


Development Of Electrochemical Sensors Suitable For In Vivo Detection For Neurotransmitters, Mengjia Hu May 2016

Development Of Electrochemical Sensors Suitable For In Vivo Detection For Neurotransmitters, Mengjia Hu

Graduate Theses and Dissertations

The electrochemical method of redox cycling was exploited to achieve new discoveries in neurotransmitter detection and to advance its suitability toward in vivo use. Redox cycling has advantages in signal amplification, selectivity of species based on their electrochemical reaction mechanisms, and limited or no background subtraction. Distinction of dopamine from norepinephrine in a mixture with an electrochemical method at unmodified electrodes was demonstrated for the first time in vitro. This ability resulted from a series of fundamental studies of redox cycling behavior of the catecholamines (dopamine, norepinephrine and epinephrine) using different electrode configurations. Taking advantage of the ECC’ mechanism associated …


Microfluidics Guided By Redox-Magnetohydrodynamics (Mhd) For Lab-On-A-Chip Applications, Vishal Sahore Dec 2013

Microfluidics Guided By Redox-Magnetohydrodynamics (Mhd) For Lab-On-A-Chip Applications, Vishal Sahore

Graduate Theses and Dissertations

Unique microfluidic control actuated by simply turning off and on microfabricated electrodes in a small-volume system was investigated for lab-on-a-chip applications. This was accomplished using a relatively new pumping technique of redox-magnetohydrodynamics (MHD), which as shown in this dissertation generated the important microfluidic features of flat flow profile and fluid circulation. MHD is driven by the body force, FB = j × B, which is the magnetic part of the Lorentz force equation, and its direction is given by the right hand rule. The ionic current density, j, was generated in an equimolar solution of potassium ferri/ferro cyanide by applying …


Studies Toward The Development Of A Microelectrode Array For Detection Of Dopamine Through Redox Cycling, Anupama Aggarwal Dec 2011

Studies Toward The Development Of A Microelectrode Array For Detection Of Dopamine Through Redox Cycling, Anupama Aggarwal

Graduate Theses and Dissertations

Redox cycling is an electrochemical technique that cycles the reversible redox species between its oxidative states repeatedly on generator and collector electrodes. Two or more individually-addressable microelectrodes located close to each other allow redox cycling to be possible. Electrochemical behavior of a biologically important molecule, dopamine is examined under redox cycling conditions. To our knowledge, this is the first report on detection of physiological concentration of dopamine in presence of up to 100 times excess ascorbate with the use of redox cycling, without the involvement of polymer coating such as Nafion®.

Microfabrication was used to produce different geometries (parallel bands …


Redox-Magnetohydrodynamic (Mhd) Microfluidics: Fundamentals, Optimization, And Applications To Analytical Chemistry, Melissa Christine Weston Dec 2010

Redox-Magnetohydrodynamic (Mhd) Microfluidics: Fundamentals, Optimization, And Applications To Analytical Chemistry, Melissa Christine Weston

Graduate Theses and Dissertations

Microfluidic systems are of great interest in analytical chemistry for the development of lab-on-a-chip devices. This dissertation describes fundamental investigations of magnetohydrodynamics with added redox species (redox-MHD) as a new microfluidic approach for use in analytical applications. Redox-MHD is attractive because it offers a unique combination of desirable features that are otherwise only available separately with individual micropumps. Redox-MHD is compatible with aqueous and nonaqueous solutions, does not require moving parts, easily reverses flow direction, and requires only low voltages. An ion flux is generated from the oxidation or reduction of an electroactive species at specific locations by activated electrodes …