Facial Type Analysis Comparison Between Mri, Cbct, And Lateral Cephalometrics, Matthew A. Sanders Sep 2010

Facial Type Analysis Comparison Between Mri, Cbct, And Lateral Cephalometrics, Matthew A. Sanders

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Single Cephalometric measurements are comparable between Cone Beam Computed Tomography (CBCT), Magnetic Resonance Imaging (MRl) and Conventional Lateral Cephalometric (LC) imaging methods. This study evaluated the agreement between the three imaging methods in facial type analysis (using a composite of 5 cephalometric measures).

Methods and Materials: Twenty-two subjects participated in this study. Cranial images were generated via three modalities: LC, CBCT and MRl. Cephalometric landmarks were identified on the three images per subject and a facial type analysis performed. An equally weighted facial type calculation composed of 5 cephalometric measurements (facial axis, facial depth, mandibular plane, lower face height, …


Creating Prediction Models For Obstructive Sleep Apnea Based On Gender, Jeffrey Hwang Sep 2010

Creating Prediction Models For Obstructive Sleep Apnea Based On Gender, Jeffrey Hwang

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Obstructive sleep apnea (OSA) is a common chronic disorder that is characterized by repetitive episodes of airflow cessation or reduction occurring during sleep as a result of partial or complete upper airway obstruction. These recurrent events have a tremendous impact on the cardiovascular system with a multitude of dangerous consequences. Numerous studies have been conducted determining etiological risk factors for OSA including anatomical predictors which have been observed with multiple imaging techniques. Cone beam computed tomography (CBCT) is a low-radiation mode of imaging that can be used to accurately identify anatomical landmarks and measure craniofacial relationships and airway dimensions. …


Using Cone Beam Computed Tomography To Identify A Prediction Model For Obstructive Sleep Apnea, Jodi Parker Sep 2009

Using Cone Beam Computed Tomography To Identify A Prediction Model For Obstructive Sleep Apnea, Jodi Parker

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Obstructive Sleep Apnea (OSA) patients have increased risk of morbidity and mortality. Early diagnosis may reduce morbidity and mortality. Prediction of OSA from imaging may help to identify OSA patients earlier in life. CBCT can be used for OSA diagnostic imaging due to its three-dimensional (3D) visualization of the upper airway and craniofacial complex. Magnification associated with conventional 2D radiography is eliminated with CBCT, and radiation to the patient is significantly less than previous modalities used to measure craniofacial & airway measurements associated with OSA. During a CBCT scan, the patient's image is taken supine, rather than the upright …


Observer Reliability Of Cephalometric Landmark Identification On 3-D Mr Images, Michael S. Pollack Sep 2009

Observer Reliability Of Cephalometric Landmark Identification On 3-D Mr Images, Michael S. Pollack

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Cephalometric analysis is a cornerstone of orthodontic diagnosis, yet much information is lost when 3-dimensional structures are assessed with 2-dimensional methods. CBCT offers 3-dimensional imaging but at the cost of higher levels of ionizing radiation. Magnetic resonance imaging provides 3-dimensional imaging without ionizing radiation and additionally imparts visualization of soft tissue structures. Prior to employing MR images for cephalometric analysis, reliability of landmark identification must be assessed. The purpose of this study was to evaluate intra- and interobserver reliability in 3-dimensional landmark identification using MR images.

Materials and Methods: Fifteen cranial MR images (3.0 T, MP-RAGE) from subjects between …


Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu Jun 2008

Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To evaluate sealant microleakage using four different application techniques.

METHODS: The four application techniques evaluated were acid etch only, Adper L-Pop bonding, Optibond bonding, and Enamel Loc One-Step Sealant. Sixty-four extracted third molar teeth were assigned on one of four application techniques (n=16) and Clinpro sealants applied according to the manufacturer's instructions. The teeth were thermocycled for 500 cycles, dyed, and embedded in resin. The samples were then sectioned and evaluated for microleakage on the buccal and lingual surfaces. Statistical methods employed to analyze the data were the Kruskal-Willis rank test and the Mann-Whitney U test.

RESULTS: No significant …


Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer Jun 2007

Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To compare the effect of traditional phosphoric acid etching with Er,Cr:YSGG laser enamel etching on the shear bond strength of sealant material.

METHODS: Extracted healthy third molars were mounted in acrylic exposing the flattest surface available. Three groups of twenty teeth were used to evaluate traditional acid etching with 37% phosphoric acid as a control group as well as two different laser settings. The sealant material was attached using specialized jigs and then subjected to shear bond strength testing utilizing the ultradent method (MTS machine). Statistical methods employed were the Kruskal-Wallis rank test and the Mann-Whitney U test.

RESULTS: …


Accuracy Of The Newtom 3g™ In Measuring The Angle Of The Articular Eminence, Rehana Khan Dec 2005

Accuracy Of The Newtom 3g™ In Measuring The Angle Of The Articular Eminence, Rehana Khan

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to determine the accuracy of the Newtom 3G™ in determining the angulation of the articular eminence. The benefits of conducting this study were to provide additional uses for the standard records that are taken for the purposes of orthodontic treatment, as well as evaluate the Newtom 3G™ for accuracy in measuring the anatomy of the glenoid fossa. This study required 20 participants that volunteered to allow their records to be used. Records evaluated were the Newtom 3G™, impressions, and wax check bite registrations. The wax record was taken using the 'forced bite' technique to …


Prevalence Of Degenerative Joint Disease In A Pre-Orthodontic Adolescent Sample, Marie Mansour Sep 2004

Prevalence Of Degenerative Joint Disease In A Pre-Orthodontic Adolescent Sample, Marie Mansour

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this research was to determine a prevalence of degenerative joint disease in our pre-orthodontic adolescent patients age ten through seventeen. The prevalence was assessed according to gender. Severity of DJD was established for each patient and a "red flag" for diagnosis was identified. The purpose was also to establish norms for joint space for patients with and without degenerative joint disease. Correlations to distal condyle position and angle classification were described. 123 consecutive patients, 77 female and 46 male T1 NewTom records were reviewed. Severity of DJD was classified according to none, mild, moderate, and severe. Sagittal …


Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim Dec 2003

Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim

Loma Linda University Electronic Theses, Dissertations & Projects

Laser etching of enamel surfaces alters the physical and chemical characteristics of the enamel. These changes in characteristics enhance the bonding to enamel. The purpose of this study was to compare the shear and tensile bond strength of Er,Cr:YSGG hydrokinetic laser system (Biolase) with 37% phosphoric acid and self etching primer 30 minutes and 72 hours after bonding. Four different laser power output setting was observed: 1.5W, 2.0W, 2.5W, and 3.0W. Two hundred forty bovine teeth free of defect, caries, and dentin exposure were mounted in acrylic resin and divided into 24 groups of 10 teeth. Sixteen groups of 10 …


The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv Sep 2003

The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv

Loma Linda University Electronic Theses, Dissertations & Projects

The radiodensity of a composite resin can greatly influence a clinician's ability to analyze a restoration for failure. The purpose of this study was to determine the relative radiopacities of 29 resin restorative materials compared to enamel, and to verify the comparable radiopacity between shades of 23 of the restorative composite resin materials. Composite resin discs measuring >5mm in diameter and 2 mm in thickness were made and polymerized. Radiographs were taken of the composite resin discs, which included an aluminum step wedge for calibration and a densitometer was used to measure the radiodensity of the composite resin samples. The …


Optimum Bonding Time Of Four Different Curing Lights, Nathan Don Cotten Jun 2001

Optimum Bonding Time Of Four Different Curing Lights, Nathan Don Cotten

Loma Linda University Electronic Theses, Dissertations & Projects

With the development of new high-intensity curing lights, the time required to bond orthodontic brackets is steadily decreasing. The objective of this study was to determine the optimum curing time for bonding orthodontic brackets using four different visible curing lights (Standard Optilux 501, High Intensity Optilux 501 with Turbo Tip, Virtuoso Plasma Arc, and ESPE LED light). This study also tested the new generation of light emitting diode (LED) lights to determine if they can be used for bonding orthodontic brackets. Three hundred freshly extracted bovine teeth were mounted in acrylic resin and divided into 20 groups of 15 teeth …


A Cephalometric Study Of The Class Ii Correction Effects Of The Eureka Spring, Ernest L. Stromeyer Aug 1997

A Cephalometric Study Of The Class Ii Correction Effects Of The Eureka Spring, Ernest L. Stromeyer

Loma Linda University Electronic Theses, Dissertations & Projects

The effect of the Eureka Spring appliance, was investigated on 37 consecutively treated, non compliant, bilateral Class II malocclusions, requiring at least 3 mm or more of additional molar correction. The mean pretreatment age of this sample was 13.9 years. All patients were treated by a single clinician utilizing the Eureka Spring. Lateral cephalographs were taken at start of orthodontic treatment (T1), at insertion of Eureka Springs (T2), and at removal of the Eureka Springs (T3). The average treatment interval between T2 and T3 was 4 months. Class II correction occurred almost entirely by dentoalveolar movement, 33% in the maxilla …


Mandibular Asymmetry In Unilateral Class Ii Malocclusion : A Cephalometric Study, Raed Z. Moussa Dec 1995

Mandibular Asymmetry In Unilateral Class Ii Malocclusion : A Cephalometric Study, Raed Z. Moussa

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study is to evaluate skeletal and dental asymmetry in unilateral class II malocclusion. A study group of 25 unilateral subdivision patients was compared to 25 class I malocclusion patients serving as the control group. Submento-vertical and frontal radiographs were used for the evaluation. Symmetry was evaluated by comparing measurements between right and left sides for both groups and matching the middle points with the midsagittal axis. Statistical paired and simple t-test were used to evaluate the difference between the two sides for both groups. The measurements showed no significant skeletal and dental asymmetries except for three …


The Rotations Of Maxillary Molars, Mandibular Molars, And Maxillary First Premolars In Acceptable Occlusions, G. Kristian Hansen Jun 1995

The Rotations Of Maxillary Molars, Mandibular Molars, And Maxillary First Premolars In Acceptable Occlusions, G. Kristian Hansen

Loma Linda University Electronic Theses, Dissertations & Projects

The rotation of the maxillary molars is considered important in the orthodontic treatment of malocclusions. In this study a computer analysis program was developed to examine the rotations of maxillary molars, mandibular molars, and maxillary first premolars in casts of permanent dentitions with acceptable occlusions. Ninety three sets of untreated "acceptable occlusion" models from the collection of the Foundation for Orthodontic Research (FOR) were scanned on a flat bed scanner at 600 dots per inch (dpi). The images were analyzed using custom software on a computer. Measurements were made by relating maxillary first permanent molars to the midline, the archform, …


Reproducibility Of Periodontal Probing, Su-Fang Wang Dec 1993

Reproducibility Of Periodontal Probing, Su-Fang Wang

Loma Linda University Electronic Theses, Dissertations & Projects

This study evaluated reproducibility of periodontal probing by conventional manual and automated force-controlled electronic probes. A total of 1206 sites (6 sites per tooth including maxillary and mandibular incisor/canine, premolar, and molar sites) in 15 patients with history of moderate or advanced chronic periodontal disease were examined. Probings included probing pocket depths (PD), as well as probing attachment levels (PAL) from a reference stent. Measurements were recorded to the nearest 0.5 mm with both methods. Patients were examined twice, 7 to 10 days apart. At each visit, all sites were probed first with the conventional probe and then with the …


The Accuracy Of Sonographic Imaging (Dolphintm Digigraph) And Standard Lateral Cephalometric Radiographs : A Comparative Study, Michael D. Teichman Jun 1991

The Accuracy Of Sonographic Imaging (Dolphintm Digigraph) And Standard Lateral Cephalometric Radiographs : A Comparative Study, Michael D. Teichman

Loma Linda University Electronic Theses, Dissertations & Projects

Radiation due to x-ray exposure is a concern, and the development of the Dolphin™ DigiGraph represents an attempt to limit this exposure. The purpose of this paper was to compare measurements (using Ricketts analysis) obtained from conventional radiographic cephalometric tracings with those obtained by computerized digitizing with the DigiGraph. Forty-six patients from the Loma Linda University School of Dentistry graduate orthodontic clinic were digitized, and the results were compared to the x-ray tracings of these patients. The results showed that seven of the twenty-one variables examined exhibited a statistical similarity between the two methods (DigiGraph and x-ray tracing). An examination …


The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley Jun 1991

The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to compare the fracture strength of ceramic brackets which are currently on the market with ceramic brackets tested in a previous study at Loma Linda. Fracture strengths of standard edgewise ceramic brackets vs. pre-torqued ceramic brackets and bicuspid ceramic brackets vs. central incisor ceramic brackets were also compared.

A total of 160 Polycrystalline brackets, 8 categories in groups if 20, were tested for fracture strength. Each bracket was tested using the same testing model that was used in the previous study at Loma Linda. The brackets were tested by torquing a wire within the …


A Modified Nance Unilateral Molar Distalizer, Tracy J. Reiner Jun 1990

A Modified Nance Unilateral Molar Distalizer, Tracy J. Reiner

Loma Linda University Electronic Theses, Dissertations & Projects

This clinical study evaluated a modified Nance appliance designed by the author to distalize molars unilaterally for Class II correction. This fixed appliance did not rely upon extraoral traction or intraoral elastics. Twelve unilateral Class II patients aged 13 to 17 were treated nonextraction with the appliance. Pretreatment and posttreatment photographs were taken of the palatal soft tissue and did not reveal any untoward changes as a result of the Nance acrylic button. All molars were corrected to an Angle's Class I relationship. Molar correction was evaluated visually and molar distalization was measured using an acrylic jig fitted to the …


Feasibility Of An Extraoral Method For Predicting Manibular Incisor Relapse, Mark J. Saylor Jun 1989

Feasibility Of An Extraoral Method For Predicting Manibular Incisor Relapse, Mark J. Saylor

Loma Linda University Electronic Theses, Dissertations & Projects

The author undertook to develop an extraoral model for predicting mandibular incisor relapse similar to the model described by Harvey and Sheldon Peck. Whereas the Peck and Peck method involves intraoral measurements, the method described in this paper relied on the taking of measurements from the patient's pre-treatment plaster models. Two hundred and sixty teeth were measured both orally and on plaster casts, and several statistical tests were performed to isolate any differences between the intraoral and extraoral methods. The principal difference was identified as the faciolingual measurement of the incisor, due to the height of contour often being subgingival …


A Sensitivity Analysis Of The Coefficients For The Transformation Of The Electrocardiographic Orthogonal Three-Lead System (Frank) To The Standard Twelve-Lead System, Rasa Ona Draugelis Sep 1985

A Sensitivity Analysis Of The Coefficients For The Transformation Of The Electrocardiographic Orthogonal Three-Lead System (Frank) To The Standard Twelve-Lead System, Rasa Ona Draugelis

Loma Linda University Electronic Theses, Dissertations & Projects

The SENSITIVITY ANALYSIS is performed on the transformation coefficients of the Frank XYZ signals generating standard 12-lead ECG with respect to diagnosis. The analysis is adapted for the individual waveform and per each lead. The disease/abnormality categories are described in terms of discrete pattern classes based on criteria used by Marquette Electronics, Inc. The nonlinear global sensitivity analysis method developed by Shuler, et al, is selected for this project. The diagnostic change in the waveform is denoted by a distance measurement from the pattern class boundary corresponding to the best-experimental coefficient estimates (Dower coefficients) to the alternate coefficient specification measurement …


Mandibular Repositioning With Frankel Appliance Therapy, Clark E. Schneekluth Jun 1983

Mandibular Repositioning With Frankel Appliance Therapy, Clark E. Schneekluth

Loma Linda University Electronic Theses, Dissertations & Projects

A sample of twelve Frankel appliance (FR-2) treated patients, in the mixed dentition stage, were selectively chosen by an orthodontist based on the Class II correction and evaluated from before treatment and end of treatment laminagraphic and lateral cephalometric radiographs. The average treatment period was 22 months (1 yr. 10 mos.). The average pre-treatment age was 9.5 years with a range from 8 to 11 years old, while the average post-treatment age was 11.3 years with a range of 10 to 13 years.

Frankel appliance therapy was the only form of mechanics used in this study.

The before treatment lateral …


The Coronary Distribution Zone : Mathematical Modelling Of The Left Ventricular Epicardial Surface For Area Calculation, Three-Dimensional Rotaton And Display, S. Matts E. Sjölander Dec 1980

The Coronary Distribution Zone : Mathematical Modelling Of The Left Ventricular Epicardial Surface For Area Calculation, Three-Dimensional Rotaton And Display, S. Matts E. Sjölander

Loma Linda University Electronic Theses, Dissertations & Projects

A computer model of the left ventricular (LV) epicardial surface was developed from Jang’s truncated ellipsoidal model, which has a minor to major axis ratio of 6:10. The model was applied in calculating the area of a segment of the myocardium, jeopardized by an impending occlusion of its associated artery. The endangered segment of the LV muscle was also visualized in different projections by rotations in three space and graphical displays simulating the three dimensions.

The area formula for the surface of the ideal model , a truncated prolate spheroid, was derived and used in producing maps for manual calculations …


Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy Jun 1980

Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this investigation was to develop methods and equipment to measure and record over any desired length of time the loss or gain in force of any material used in orthodontics that can produce a force upon an object. The material and the object being acted upon should not be disturbed while measuring that force.

Holding devices were designed and constructed in two basic forms. For intrusive and extrusive type forces, a load cell was fixed horizontally in such a position that an adjustable tube with a set screw to hold the wire could be rotated to cause …


Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer Jun 1979

Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer

Loma Linda University Electronic Theses, Dissertations & Projects

Fracture of orthodontic appliances can be a problem because of the time involved to replace and repair them. It has been shown that most failures have been a result of fatigue fracture, i.e., failure resulting from cyclic loading.

The purpose of this study was to determine what effect variation of the type of orthodontic wire and heat treatment had on fatigue resistance. A device was constructed to put a cyclic load on a piece of wire until fracture. Two types of cobalt-chromium alloy wire (Blue and Green Elgiloy from Rocky Mountain Orthodontics) and three types of stain less steel wire …


The Effect Of Warmed Humidified Oxygen On The Temperature Of Depressed Newborns, Earlene Scharping Oct 1977

The Effect Of Warmed Humidified Oxygen On The Temperature Of Depressed Newborns, Earlene Scharping

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to evaluate the effect of warmed humidified oxygen on the body temperature of depressed newborns and compare it to the effect of unwarned un-humidified oxygen administered under similar circumstances. The sample group consisted of a total of ten infants (five control and five experimental) with birth weights > 2000 gms who had an Apgar score of less than seven at birth and who required the administration of oxygen. The control group received oxygen in the routine delivery room manner (unwarned and un-humidified). The experimental group received oxygen which had been warmed to a temperature of …


Ultrasonic Versus Hand Filing Of The Human Root Canal System, Howard W. Scholz Jr. Jun 1977

Ultrasonic Versus Hand Filing Of The Human Root Canal System, Howard W. Scholz Jr.

Loma Linda University Electronic Theses, Dissertations & Projects

A comparison was made of ultrasonic filing versus hand filing using three solutions to flood the canals of 24 extracted human maxillary central incisors. A modified PR-30 Cavitron insert was used in a Cavitron 1010 unit for the ultrasonic filing. The clinical crown was removed with a diamond saw and water spray at the cemento-enamel junction. The two major groups were ultrasonic filing versus hand filing; the three subgroups were solution/solvents - 10% EDTA, 2.0% NaOCl, and distilled water.

After filing, the roots were grooved longitudinally with a high speed bur and cracked opened with a mallet and chisel. The …


Xeroradiography & Conventional Radiography : Comparative Imaging Of The Temporomandibular Joint, Nelson R. Gatov Jun 1977

Xeroradiography & Conventional Radiography : Comparative Imaging Of The Temporomandibular Joint, Nelson R. Gatov

Loma Linda University Electronic Theses, Dissertations & Projects

An investigation was conducted to evaluate the application of Xeroradiography for imaging the Temporomandibular Joint using the Updegrave and Weinberg positioning boards and to compare these images to those obtained by conventional radiography using the same positioning boards.

A cadaver head in which three spherical radiopaque implants had been placed was used in this study. A General Electric Model 1000 (Dental Unit) was the source of radiation. The conventional radiographs were produced on Dupont Cronex 2DC film and processed by a Phillips 810 automatic processed by a Xerox "125 System".

MAGNIFICATION

A comparison of the implant sphere diameters and the …


Relationship Between Some Demographic Characteristics And Adverse Reactions Experienced By Women Undergoing A Therapeutic Abortion While Awake, Karen K. House May 1977

Relationship Between Some Demographic Characteristics And Adverse Reactions Experienced By Women Undergoing A Therapeutic Abortion While Awake, Karen K. House

Loma Linda University Electronic Theses, Dissertations & Projects

With the liberalization of abortion laws by the Supreme Court in 1973, American women have been able to obtain therapeutic abortions in hospitals and out-patient clinics in ever increasing numbers. With the increased number of women seeking abortions the medical field has responded with abortion procedures that are safe and relatively quick. With the speed doctors use to perform the procedure, many women may wish to take advantage of the medically safer method of abortion under local anesthesia. However, some women are unable to withstand the psychological and physical stress associated with a therapeutic abortion while awake. It would be …


Evaluation Of A Precision Filing Test For Predicting Dental Technic Performance, Douglass Roberts Jun 1976

Evaluation Of A Precision Filing Test For Predicting Dental Technic Performance, Douglass Roberts

Loma Linda University Electronic Theses, Dissertations & Projects

A precision filing test involving the reduction of a steel cylinder to a perfect cube with the use of a hand file and bench vise was devised as a diagnostic tool for the early detection of freshman students having technic difficulties. The test was administered to 188 freshman dental students in three classes at Loma Linda University, School of Dentistry. Subjective and objective scores were then statistically compared with subsequent technic and clinic grades of the students. The simple linear correlations between the predictor test variable and criterion grades were statistically significant for one class and for the combined classes …


A Cephalometric Study Of Mandibulo-Facial Disostosis In Monozygotic Twins Using Computerized Methods, Lyn M. Lamberton Jun 1974

A Cephalometric Study Of Mandibulo-Facial Disostosis In Monozygotic Twins Using Computerized Methods, Lyn M. Lamberton

Loma Linda University Electronic Theses, Dissertations & Projects

An investigation using computerized cephalometrics has been conducted to consider the cephalometric factors responsible for the characteristic appearance evident in individuals afflicted with Mandibulo-Facial Dysostosis. A pair of Negro monozygotic affected twins were studied using the other 10 non-affected members of the family as a control to minimize the environmental and hereditary factors. The Rocky Mountain Data System was utilized to analyze the lateral and frontal cephalometric radiographs of each individual using Ricketts Analysis and the data were subjected to statistical tests to determine the factors contributory to the syndrome. Age and size were considered and adjustments were made to …