Open Access. Powered by Scholars. Published by Universities.®

Rehabilitation and Therapy Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Rehabilitation and Therapy

Impact Of Motor Therapy With Dynamic Body-Weight Support On Functional Independence Measures In Traumatic Brain Injury: An Exploratory Study, Emily F. Anggelis, Elizabeth Salmon Powell, Philip M. Westgate, Amanda C. Glueck, Lumy Sawaki Dec 2019

Impact Of Motor Therapy With Dynamic Body-Weight Support On Functional Independence Measures In Traumatic Brain Injury: An Exploratory Study, Emily F. Anggelis, Elizabeth Salmon Powell, Philip M. Westgate, Amanda C. Glueck, Lumy Sawaki

Physical Medicine and Rehabilitation Faculty Publications

BACKGROUND: Contemporary goals of rehabilitation after traumatic brain injury (TBI) aim to improve cognitive and motor function by applying concepts of neuroplasticity. This can be challenging to carry out in TBI patients with motor, balance, and cognitive impairments.

OBJECTIVE: To determine whether use of dynamic body-weight support (DBWS) would allow safe administration of intensive motor therapy during inpatient rehabilitation and whether its use would yield greater improvement in functional recovery than standard-of-care (SOC) therapy in adults with TBI.

METHODS: Data in this retrospective cohort study was collected from patients with TBI who receive inpatient rehabilitation incorporating DBWS (n = …


Chronic Muscle Weakness And Mitochondrial Dysfunction In The Absence Of Sustained Atrophy In A Preclinical Sepsis Model, Allison M. Owen, Samir P. Patel, Jeffrey D. Smith, Beverly K. Balasuriya, Stephanie F. Mori, Gregory S. Hawk, Arnold J. Stromberg, Naohide Kuriyama, Masao Kaneki, Alexander G. Rabchevsky, Timothy A. Butterfield, Karyn A. Esser, Charlotte A. Peterson, Marlene E. Starr, Hiroshi Saito Dec 2019

Chronic Muscle Weakness And Mitochondrial Dysfunction In The Absence Of Sustained Atrophy In A Preclinical Sepsis Model, Allison M. Owen, Samir P. Patel, Jeffrey D. Smith, Beverly K. Balasuriya, Stephanie F. Mori, Gregory S. Hawk, Arnold J. Stromberg, Naohide Kuriyama, Masao Kaneki, Alexander G. Rabchevsky, Timothy A. Butterfield, Karyn A. Esser, Charlotte A. Peterson, Marlene E. Starr, Hiroshi Saito

Physiology Faculty Publications

Chronic critical illness is a global clinical issue affecting millions of sepsis survivors annually. Survivors report chronic skeletal muscle weakness and development of new functional limitations that persist for years. To delineate mechanisms of sepsis-induced chronic weakness, we first surpassed a critical barrier by establishing a murine model of sepsis with ICU-like interventions that allows for the study of survivors. We show that sepsis survivors have profound weakness for at least 1 month, even after recovery of muscle mass. Abnormal mitochondrial ultrastructure, impaired respiration and electron transport chain activities, and persistent protein oxidative damage were evident in the muscle of …


A Low-Cost Soft Robotic Hand Exoskeleton For Use In Therapy Of Limited Hand–Motor Function, Grant Rudd, Liam Daly, Vukica Jovanovic, Filip Cukov Sep 2019

A Low-Cost Soft Robotic Hand Exoskeleton For Use In Therapy Of Limited Hand–Motor Function, Grant Rudd, Liam Daly, Vukica Jovanovic, Filip Cukov

Engineering Technology Faculty Publications

We present the design and validation of a low-cost, customizable and 3D-printed anthropomorphic soft robotic hand exoskeleton for rehabilitation of hand injuries using remotely administered physical therapy regimens. The design builds upon previous work done on cable actuated exoskeleton designs by implementing the same kinematic functionality, but with the focus shifted to ease of assembly and cost effectiveness as to allow patients and physicians to manufacture and assemble the hardware necessary to implement treatment. The exoskeleton was constructed solely from 3D-printed and widely available of-the-shelf components. Control of the actuators was realized using an Arduino microcontroller, with a custom-designed shield …


Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin Jul 2019

Improving 3d Printed Prosthetics With Sensors And Motors, Rachel Zarin

Honors Projects

A 3D printed hand and arm prosthetic was created from the idea of adding bionic elements while keeping the cost low. It was designed based on existing models, desired functions, and materials available. A tilt sensor keeps the hand level, two motors move the wrist in two different directions, a limit switch signals the fingers to open and close, and another motor helps open and close the fingers. All sensors and motors were built on a circuit board, programmed using an Arduino, and powered by a battery. Other supporting materials include metal brackets, screws, guitar strings, elastic bands, small clamps, …


Long-Dose Intensive Therapy Is Necessary For Strong, Clinically Significant, Upper Limb Functional Gains And Retained Gains In Severe/Moderate Chronic Stroke, Janis J. Daly, Jessica P. Mccabe, John P. Holcomb, Michelle Monkiewicz, Jennifer Gansen, Svetlana Pundik Jul 2019

Long-Dose Intensive Therapy Is Necessary For Strong, Clinically Significant, Upper Limb Functional Gains And Retained Gains In Severe/Moderate Chronic Stroke, Janis J. Daly, Jessica P. Mccabe, John P. Holcomb, Michelle Monkiewicz, Jennifer Gansen, Svetlana Pundik

Mathematics and Statistics Faculty Publications

Background. Effective treatment methods are needed for moderate/severely impairment chronic stroke. Objective. The questions were the following: (1) Is there need for long-dose therapy or is there a mid-treatment plateau? (2) Are the observed gains from the prior-studied protocol retained after treatment? Methods. Single-blind, stratified/randomized design, with 3 applied technology treatment groups, combined with motor learning, for long-duration treatment (300 hours of treatment). Measures were Arm Motor Ability Test time and coordination-function (AMAT-T, AMAT-F, respectively), acquired pre-/posttreatment and 3-month follow-up (3moF/U); Fugl-Meyer (FM), acquired similarly with addition of mid-treatment. Findings. There was no group difference in …


Volleyball Overhead Swing Volume And Injury Frequency Over The Course Of A Season, Heather Wolfe, Katherine Poole, Alejandro G. Villasante Tezanos, Robert A. English, Timothy L. Uhl Feb 2019

Volleyball Overhead Swing Volume And Injury Frequency Over The Course Of A Season, Heather Wolfe, Katherine Poole, Alejandro G. Villasante Tezanos, Robert A. English, Timothy L. Uhl

Statistics Faculty Publications

Background: Overuse injuries are common in volleyball; however, few studies exist that quantify the workload of a volleyball athlete in a season. The relationship between workload and shoulder injury has not been extensively studied in women's collegiate volleyball athletes.

Hypothesis/Purpose: This study aims to quantify shoulder workloads by counting overhead swings during practice and matches. The purpose of the current study is to provide a complete depiction of typical overhead swings, serves, and hits, which occur in both practices and matches. The primary hypothesis was that significantly more swings will occur in practices compared to matches. The secondary hypothesis was …


Walking With A Robotic Exoskeleton Does Not Mimic Natural Gait: A Within-Subjects Study, Chad Swank, Sharon Wang-Price, Fan Gao, Sattam Almutairi Jan 2019

Walking With A Robotic Exoskeleton Does Not Mimic Natural Gait: A Within-Subjects Study, Chad Swank, Sharon Wang-Price, Fan Gao, Sattam Almutairi

Kinesiology and Health Promotion Faculty Publications

Background: Robotic exoskeleton devices enable individuals with lower extremity weakness to stand up and walk over ground with full weight-bearing and reciprocal gait. Limited information is available on how a robotic exoskeleton affects gait characteristics.

Objective: The purpose of this study was to examine whether wearing a robotic exoskeleton affects temporospatial parameters, kinematics, and muscle activity during gait.

Methods: The study was completed by 15 healthy adults (mean age 26.2 [SD 8.3] years; 6 males, 9 females). Each participant performed walking under 2 conditions: with and without wearing a robotic exoskeleton (EKSO). A 10-camera motion analysis system synchronized with 6 …