Open Access. Powered by Scholars. Published by Universities.®

Rehabilitation and Therapy Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Rehabilitation and Therapy

Walking Kinematics In Young Children With Limb Loss Using Early Versus Traditional Prosthetic Knee Prescription Protocols, Mark Daniel Geil, Zahra Safaeepour, Brian Giavedoni, Colleen Coulter Apr 2020

Walking Kinematics In Young Children With Limb Loss Using Early Versus Traditional Prosthetic Knee Prescription Protocols, Mark Daniel Geil, Zahra Safaeepour, Brian Giavedoni, Colleen Coulter

Faculty and Research Publications

The traditional treatment protocol for young children with congenital or acquired amputations at or proximal to the knee prescribes a prosthesis without a working knee joint, based in part on the assumption that a child learning to walk cannot properly utilize a passively flexing prosthetic knee component. An alternative to this Traditional Knee (TK) protocol is an “Early Knee” (EK) protocol, which prescribes an articulating prosthetic knee in the child’s first prosthesis, during development of crawling and transitioning into and out of upright positions. To date, no study has compared samples of children with limb loss at or proximal to …


Walking Biomechanics And Energetics Of Individuals With A Visual Impairment: A Preliminary Report, Hunter J. Bennett, Kevin A. Valenzuela, Kristina Fleenor, Steven Morrison, Justin A. Haegele Jan 2019

Walking Biomechanics And Energetics Of Individuals With A Visual Impairment: A Preliminary Report, Hunter J. Bennett, Kevin A. Valenzuela, Kristina Fleenor, Steven Morrison, Justin A. Haegele

Human Movement Sciences & Special Education Faculty Publications

Purpose.

Although walking gait in sighted populations is well researched, few studies have investigated persons with visual impairments (VIs). Given the lack of physical activity in people with VIs, it is possible that reduced efficiency in walking could adversely affect activity. The purposes of this preliminary study were to (1) examine the biomechanics and energetics utilized during independent and guided walking in subjects with VIs, and (2) compare gait biomechanics between people with VIs and sighted controls.

Methods.

Three-dimensional motion capture and force platforms were used during independent and guided walking at self-selected speeds. Joint angles, moments, external work, and …


Gait Rehabilitation Using Functional Electrical Stimulation Induces Changes In Ankle Muscle Coordination In Stroke Survivors: A Preliminary Study, Jessica L. Allen, Lena H. Ting, Trisha M. Kesar Dec 2018

Gait Rehabilitation Using Functional Electrical Stimulation Induces Changes In Ankle Muscle Coordination In Stroke Survivors: A Preliminary Study, Jessica L. Allen, Lena H. Ting, Trisha M. Kesar

Faculty & Staff Scholarship

No abstract provided.


The Effect Of A Powered Ankle Foot Orthosis On Walking In A Stroke Subject: A Case Study, Ali Pourghasem, Ismail Ebrahimi Takamjani, Mohammad Taghi Karimi, Mohammad Kamali, Mohammad Jannesari, Iman Salafian Dec 2016

The Effect Of A Powered Ankle Foot Orthosis On Walking In A Stroke Subject: A Case Study, Ali Pourghasem, Ismail Ebrahimi Takamjani, Mohammad Taghi Karimi, Mohammad Kamali, Mohammad Jannesari, Iman Salafian

Department of Mechanical and Materials Engineering: Faculty Publications

[Purpose] Standing and walking are impaired in stroke patients. Therefore, assisted devices are required to restore their walking abilities. The ankle foot orthosis with an external powered source is a new type of orthosis. The aim of this study was to evaluate the performance of a powered ankle foot orthosis compared with unpowered orthoses in a stroke patient.

[Subjects and Methods] A single stroke subject participated in this study. The subject was fitted with three types of ankle foot orthosis (powered, posterior leg spring, and carbon ankle foot orthoses). He was asked to walk with and without the three types …


Stroke-Related Effects On Maximal Dynamic Hip Flexor Fatigability And Functional Implications, Henry Kuhnen, Megan M. Rybar, Tanya Onushko, Ryan E. Doyel, Sandra K. Hunter, Brian D. Schmit, Allison Hyngstrom Mar 2015

Stroke-Related Effects On Maximal Dynamic Hip Flexor Fatigability And Functional Implications, Henry Kuhnen, Megan M. Rybar, Tanya Onushko, Ryan E. Doyel, Sandra K. Hunter, Brian D. Schmit, Allison Hyngstrom

Exercise Science Faculty Research and Publications

Introduction: Stroke-related changes in maximal dynamic hip flexor muscle fatigability may be more relevant functionally than isometric hip flexor fatigability. Methods: Ten chronic stroke survivors performed 5 sets of 30 hip flexion maximal dynamic voluntary contractions (MDVC). A maximal isometric voluntary contraction (MIVC) was performed before and after completion of the dynamic contractions. Both the paretic and nonparetic legs were tested. Results: Reduction in hip flexion MDVC torque in the paretic leg (44.7%) was larger than the nonparetic leg (31.7%). The paretic leg had a larger reduction in rectus femoris EMG (28.9%) between the first and last …


Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez May 2014

Biomechanical Analysis Of Gait Kinetics Resulting From Use Of A Vacuum Socket On A Transtibial Prosthesis, Maria De Lourdes Ramos Gonzalez

Honors College Theses

The technology and design of lower limb prosthetics have evolved greatly since their introduction. The current study proposed to compare the effects of a conventional pin socket attachment and a vacuum socket attachment for a transtibial amputee. Whereas traditional measurements of gait utilize force plates and camera systems, this study made use of a small tri-axial load cell located at the base of the socket to measure the forces and moments exerted during a regular gait cycle. The hypothesis tested stated that a vacuum pump socket attachment, when compared to a non-vacuum (pin) socket, will have a significant effect on …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …