Open Access. Powered by Scholars. Published by Universities.®

Other Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Other Medicine and Health Sciences

Absolute And Relative Changes (Delta) In Troponin I For Early Diagnosis Of Myocardial Infarction: Results Of A Prospective Multicenter Trial., Alan B Storrow, Richard M Nowak, Deborah B Diercks, Adam J Singer, Alan H B Wu, Erik Kulstad, Frank Lovecchio, Christian Fromm, Gary Headden, Tracie Potis, Christopher J Hogan, Jon W Schrock, Daniel P Zelinski, Marna Greenberg, Robert H Christenson, James C Ritchie, Janna S Chamberlin, Kurtis R Bray, Daniel W Rhodes, Deirdre Trainor, Paula C Southwick Jan 2015

Absolute And Relative Changes (Delta) In Troponin I For Early Diagnosis Of Myocardial Infarction: Results Of A Prospective Multicenter Trial., Alan B Storrow, Richard M Nowak, Deborah B Diercks, Adam J Singer, Alan H B Wu, Erik Kulstad, Frank Lovecchio, Christian Fromm, Gary Headden, Tracie Potis, Christopher J Hogan, Jon W Schrock, Daniel P Zelinski, Marna Greenberg, Robert H Christenson, James C Ritchie, Janna S Chamberlin, Kurtis R Bray, Daniel W Rhodes, Deirdre Trainor, Paula C Southwick

Marna R Greenberg DO, MPH, FACEP

OBJECTIVES: We investigated absolute and relative cardiac troponin I (TnI) delta changes, optimal sampling protocols, and decision thresholds for early diagnosis of myocardial infarction (MI). Serial cardiac biomarker values demonstrating a rise and/or fall define MI diagnosis; however the magnitude of change, timing, and diagnostic accuracy of absolute versus relative (percentage) deltas remains unsettled. METHODS: We prospectively measured TnI (AccuTnI+3™, Beckman Coulter) at serial time intervals in 1929 subjects with chest pain or equivalent symptoms of acute coronary syndrome at 14 medical centers. Diagnosis was adjudicated by an independent central committee. RESULTS: Elevated TnI above a threshold of 0.03ng/mL demonstrated …


Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya Jan 2015

Real-Time Mri-Guided Catheter Tracking Using Hyperpolarized Silicon Particles, Nicholas Whiting, Jingzhe Hu, Jay V. Shah, Maja C. Cassidy, Erik Cressman, Niki Zacharias Millward, David G. Menter, Charles M. Marcus, Pratip K. Bhattacharya

Nicholas Whiting

Visualizing the movement of angiocatheters during endovascular interventions is typically accomplished using x-ray fluoroscopy. There are many potential advantages to developing magnetic resonance imaging-based approaches that will allow three-dimensional imaging of the tissue/vasculature interface while monitoring other physiologically-relevant criteria, without exposing the patient or clinician team to ionizing radiation. Here we introduce a proof-of-concept development of a magnetic resonance imaging-guided catheter tracking method that utilizes hyperpolarized silicon particles. The increased signal of the silicon particles is generated via low-temperature, solid-state dynamic nuclear polarization, and the particles retain their enhanced signal for ≥40 minutes—allowing imaging experiments over extended time durations. The …