Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Anti-VEGF injection safety (1)
- Anti-VEGF injections (1)
- Bilateral vs Unilateral anti VEGF (1)
- Biometry (1)
- Cataract surgery (1)
-
- Endophthalmitis rate (1)
- Health service delivery (1)
- Intraocular pressure (1)
- Low vision (1)
- Patient perspectives (1)
- Patient satisfaction (1)
- Premium IOLs (1)
- Refractive surprises (1)
- SS-OCT (1)
- Stakeholder perspectives (1)
- Stroke (1)
- Suprachoroidal (1)
- Triamcinolone acetonide (1)
- Visual deficits (1)
- Visual impairment (1)
Articles 1 - 4 of 4
Full-Text Articles in Medical Specialties
Effect Of Suprachoroidal Triamcinolone On Intraocular Pressure: A Systematic Review And Meta-Analysis, Altamash Shahriyar Ghazanfar, Aly Hamza Khowaja, Haroon Tayyab
Effect Of Suprachoroidal Triamcinolone On Intraocular Pressure: A Systematic Review And Meta-Analysis, Altamash Shahriyar Ghazanfar, Aly Hamza Khowaja, Haroon Tayyab
Department of Ophthalmology & Visual Sciences
Background: Triamcinolone acetonide is a synthetic corticosteroid with multiple ocular uses. Like other corticosteroids, it too is associated with ocular side effects such as increased intraocular pressure (IOP), glaucoma and cataracts. Suprachoroidal administration of triamcinolone is hoped to reduce the ocular side effects of the drug, especially rises in IOP. Our systematic review and meta-analysis aims to study this phenomenon.
Objectives: The purpose of this study was to evaluate the effect of suprachoroidal triamcinolone injections on IOP.
Design: Systematic review and meta-analysis.
Methods: We utilized the Medline, Scopus and Cochrane databases for this review. Studies published till June 2023, which …
Accuracy Of Swept Source Biometry Device In Detecting Macular Diseases Compared With Swept Source Oct, Sidra Zafar, Taha Muneer Ahmed, Rashid Baig, Irfan Jeeva, Rehman Siddiqui
Accuracy Of Swept Source Biometry Device In Detecting Macular Diseases Compared With Swept Source Oct, Sidra Zafar, Taha Muneer Ahmed, Rashid Baig, Irfan Jeeva, Rehman Siddiqui
Department of Ophthalmology & Visual Sciences
Objective: To assess the diagnostic accuracy of the IOLMaster 700 foveal scans to detect foveal pathology compared with a standard swept-source optical coherence tomography (SS-OCT) device.
Results: One hundred seventy eye scans of 95 patients were included in the final analyses. Ninety-nine (58.2%) scans were classified as abnormal by SS-OCT. Mean sensitivity of the biometry device was 67.5% (range: 51-84%) and mean specificity was 69.5% (range: 44-95%). Intra-class correlation coefficients were 0.912 and 0.835, for reader 1 and 2, respectively. Area under the curve for receiver operating curve was 0.726. Foveal scans of the IOLMaster 700 can provide clinically useful …
Safety Of Simultaneous Bilateral Intravitreal Versus Unilateral Anti-Vasculo-Endothelial Growth Factors Injection In An Operating Room Setting, Irfan Kabiruddin Jeeva, Sidra Masud, Rehman Siddiqui, Hadees Murad Fahad
Safety Of Simultaneous Bilateral Intravitreal Versus Unilateral Anti-Vasculo-Endothelial Growth Factors Injection In An Operating Room Setting, Irfan Kabiruddin Jeeva, Sidra Masud, Rehman Siddiqui, Hadees Murad Fahad
Department of Ophthalmology & Visual Sciences
Objectives: Chorioretinal diseases requiring the use of anti-vascular endothelial growth (anti-VEGF) injections often occur in both eyes simultaneously. This can necessitate injecting both eyes together rather than one eye at a time. The purpose of the study was to determine whether simultaneous bilateral intravitreal injections of anti-VEGF agents are safe when administered in an operation theatre setting.
Methods: Retrospective review of data was conducted. Single center study conducted in a tertiary care hospital in Karachi Pakistan. Approximately 30,000 eyes that received anti-VEGF injection during a 10-year study period were included (March 2008-February 2018). Patients who were lost to follow up …
Barriers To Care For Poststroke Visual Deficits In Alberta, Canada, Kiran Pohar Manhas, Karim F. Damji, Katelyn Brehon, Jennis Jiang, Peter Faris, Fiona Costello
Barriers To Care For Poststroke Visual Deficits In Alberta, Canada, Kiran Pohar Manhas, Karim F. Damji, Katelyn Brehon, Jennis Jiang, Peter Faris, Fiona Costello
Department of Ophthalmology & Visual Sciences
Poststroke visual impairment (VI) negatively affects rehabilitation potential and quality of life for stroke survivors. In this cross-sectional observational study, stroke survivors and providers were surveyed to quantify perspectives regarding care for poststroke VI in Alberta, Canada (n = 46 survivors; n = 87 providers). Few patients (35%) felt prepared to cope with VI at the time of discharge from acute stroke and inpatient rehabilitation settings. Less than 25% of stroke survivors, and <16% of providers, felt referral processes were adequate. 95.2% of providers and 82% of stroke survivors advocated for a provincial clinical pathway to improve care quality for poststroke VI.