Open Access. Powered by Scholars. Published by Universities.®

Medical Specialties Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Medical Specialties

Favorable Outcomes With Ventricular Assist Device Exchange, Megan Carroll, Meghan Tooman, Markian Bochan, Christopher Salerno, Ashwin Ravichandran Mar 2019

Favorable Outcomes With Ventricular Assist Device Exchange, Megan Carroll, Meghan Tooman, Markian Bochan, Christopher Salerno, Ashwin Ravichandran

The VAD Journal

Left ventricular assist device (LVAD) therapy remains a vital therapeutic option for patients with end-stage heart failure. Unfortunately, adverse events can occur and progress to require consideration for device exchange once the failure of medical management becomes evident, especially when heart transplantation is not possible in a timely manner. The aim of this analysis is to describe the incidence and outcomes of LVAD exchanges at our institution. Between April 2008 and May 2017, 397 patients underwent LVAD implantation, with 32 of those patients subsequently receiving exchange upon the recommendation of our multidisciplinary team due to refractory infection (n=12), device malfunction …


Decrease In Driveline Infections With Change In Driveline Management Protocol, Saima Aslam, Jennifer Dan, Amanda Topik, Michael Belyk, Francesca Torriani, Randy Taplitz, Jorge Silva-Enciso, Denise Barnard, Barry Greenberg, Jack Copeland, Victor Pretorius, Eric Adler Mar 2016

Decrease In Driveline Infections With Change In Driveline Management Protocol, Saima Aslam, Jennifer Dan, Amanda Topik, Michael Belyk, Francesca Torriani, Randy Taplitz, Jorge Silva-Enciso, Denise Barnard, Barry Greenberg, Jack Copeland, Victor Pretorius, Eric Adler

The VAD Journal

Background: Driveline infections (DLI) are a significant cause of morbidity and mortality in ventricular assist device (VAD) recipients. We compared driveline infection (DLI) rate after an institutional change in driveline management protocol.

Methods: We retrospectively reviewed records of left VAD recipients at our institution, based on driveline management. Group 1: daily driveline dressing change consisting of chlorhexidine cleansing, sterile 4x4 gauze, and use of an abdominal binder. Group 2: Dressing change every 3 days consisting of chlorhexidine cleansing, non-sterile silver-impregnated foam with overlying clear dressing, and use of a driveline anchor. Follow-up was censored at first DLI, device removal, transplant …