Open Access. Powered by Scholars. Published by Universities.®

Other Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Dosimetry

2012

Articles 1 - 1 of 1

Full-Text Articles in Other Medical Sciences

Development And Implementation Of A Remote Audit Tool For High Dose Rate (Hdr) 192ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry, Kevin Casey Aug 2012

Development And Implementation Of A Remote Audit Tool For High Dose Rate (Hdr) 192ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry, Kevin Casey

Dissertations & Theses (Open Access)

This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, …