Articles 1 - 4 of 4
Full-Text Articles in Other Medical Sciences
Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed Tomography Image Sets For Stereotactic Body Radiation Therapy, David A. Zamora
Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed Tomography Image Sets For Stereotactic Body Radiation Therapy, David A. Zamora
Dissertations & Theses (Open Access)
The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to …
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Evaluation Of The Quantitative Accuracy Of A Commercially-Available Positron Emission Mammography Scanner, Adam Springer
Dissertations & Theses (Open Access)
Objective: The PEM Flex Solo II (Naviscan, Inc., San Diego, CA) is currently the only commercially-available positron emission mammography (PEM) scanner. This scanner does not apply corrections for count rate effects, attenuation or scatter during image reconstruction, potentially affecting the quantitative accuracy of images. This work measures the overall quantitative accuracy of the PEM Flex system, and determines the contributions of error due to count rate effects, attenuation and scatter.
Materials and Methods: Gelatin phantoms were designed to simulate breasts of different sizes (4 – 12 cm thick) with varying uniform background activity concentration (0.007 – 0.5 μCi/cc), cysts and …
An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick
An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick
Dissertations & Theses (Open Access)
In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …
Development And Validation Of A Measurement Scale To Analyze The Environment For Evidence-Based Medicine Learning And Practice By Medical Residents, Fangqiong Mi
Wayne State University Dissertations
A growing number of residency programs are instituting curricula to include the component of evidence-based medicine (EBM) principles and process. However, these curricula may not be able to achieve the optimal learning outcomes, perhaps because various contextual factors are often overlooked when EBM training is being designed, developed, and implemented. The purpose of the study was to develop and validate an instrument, the EBM Environment Scale, to analyze the environment for EBM learning and practice as perceived by medical residents.
The development of the EBM Environment Scale underwent the process of content domain identification, item generation, review by content experts …