Open Access. Powered by Scholars. Published by Universities.®

Other Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 12 of 12

Full-Text Articles in Other Medical Sciences

Hepatocellular Carcinoma Image-Guided Intervention: Quantitative Characterization Of Reagents For Thermochemical Ablation, Emily A. Thompson May 2022

Hepatocellular Carcinoma Image-Guided Intervention: Quantitative Characterization Of Reagents For Thermochemical Ablation, Emily A. Thompson

Dissertations & Theses (Open Access)

Thermochemical ablation (TCA) is a minimally invasive therapy under development for hepatocellular carcinoma, a leading cause of cancer death worldwide. TCA utilizes acid-base chemistry delivered simultaneously to induce local ablation when administered. When delivered via a mixing catheter placed directly into the tumor, acid (e.g., AcOH) and base (e.g., NaOH) react to completion at the catheter tip, producing the acetate salt, water, and releasing heat (Δ>50°C) in sufficient quantities to induce lethal osmotic and thermal stress in tumor cells. However, these two reagents are not distinguishable from tissues with noninvasive imaging modalities, which makes monitoring the delivery of TCA …


Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta Aug 2021

Advancement Of A 3d Computational Phantom And Its Age Scaling Methodologies For Retrospective Dose Reconstruction Studies, Aashish Gupta

Dissertations & Theses (Open Access)

We have used a 3D age-scalable computational phantom for over two decades for retrospective dose reconstruction studies of childhood cancer survivors (CCS) treated with 2D historic radiotherapy (RT). However, our phantom and its age scaling functions (ASF) must be updated so that it can be used in studies that include survivors treated with contemporary RT. We aimed to implement our phantom and its age scaling functions in DICOM format and determine the feasibility of applying our ASFs to accurately scale the whole-body CT-based anatomies.

In the implementation study, we developed Python scripts that model the phantom and ASFs in a …


Quantitative Magnetic Resonance Imaging For The Early Prediction Of Treatment Response In Triple Negative Breast Cancer, Benjamin C. Musall Aug 2021

Quantitative Magnetic Resonance Imaging For The Early Prediction Of Treatment Response In Triple Negative Breast Cancer, Benjamin C. Musall

Dissertations & Theses (Open Access)

Triple Negative Breast Cancer (TNBC) is an aggressive subtype of breast cancer which lacks upregulated hormone receptors. Because of this, it is not vulnerable to clinically available targeted therapies. When treated with standard of care neoadjuvant systemic therapy (NAST), TNBC only shows approximately a 40% rate of pathologic complete response (pCR). A biomarker which could predict TNBC response to NAST early during treatment would be useful, as it would allow for non-responders to be triaged to alternative therapies and potentially allow for the treatment of responders to be de-escalated.

Quantitative Magnetic Resonance Imaging (MRI) may be used to probe and …


Nuclear-Targeted Gold Nanoparticles Enhance The Effects Of Radiation Therapy With And Without Liposomal Delivery, Maureen Aliru Dec 2020

Nuclear-Targeted Gold Nanoparticles Enhance The Effects Of Radiation Therapy With And Without Liposomal Delivery, Maureen Aliru

Dissertations & Theses (Open Access)

Less that 10% of pancreatic cancer patients are eligible for curative resection, and clinical trials evaluating chemoradiation in locally advanced patients with unresectable disease have been largely disappointing. New and creative therapeutic approaches are needed to address the unment need for treatment options. The objective of this thesis is to advance radiosensitization of treatment-resistant densely desmoplastic pancreatic cancer using nanoparticles to surmount biological barriers to effective particle distribution for DNA-targeting.

Clinical translation of radiosensitizing nanoparticles has stalled owing to technical challenges. Current strategies to use AuNPs for radiosensitization require large quantities of gold, kilovoltage x-rays, immediate irradiation after intravenous administration, …


Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower Aug 2019

Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations Of Microdosimetry, Mark A. Newpower

Dissertations & Theses (Open Access)

Proton therapy is a radiotherapy modality that can offer a better physical dose distribution when compared to photon radiotherapy by taking advantage of the Bragg peak, a narrow region of rapid energy loss. Proton therapy is also known to offer an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. However, there is mounting clinical evidence, and a significant number of in vitro …


Improved Target Coverage Of Spinal Metastases Through The Use Of Flattening Filter Free Beams, Laura Bennett Aug 2018

Improved Target Coverage Of Spinal Metastases Through The Use Of Flattening Filter Free Beams, Laura Bennett

Dissertations & Theses (Open Access)

Of the patients that are diagnosed with metastatic disease, up to 40% will develop vertebral osseous metastases. These metastases tend to be located in close proximity to the spinal cord itself, making it difficult to achieve the recommended minimum dose of 14 Gy for single fraction SBRT or 21 Gy1 for three fraction SBRT while maintaining acceptable doses to the cord and cauda equina. This proximity of the target to critical structures has the potential to compromise the efficacy of the radiation treatment plan in favor of reducing normal tissue dose, resulting in poor local control and tumor recurrence …


Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd Dec 2012

Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd

Dissertations & Theses (Open Access)

This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in …


Development And Implementation Of A Remote Audit Tool For High Dose Rate (Hdr) 192ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry, Kevin Casey Aug 2012

Development And Implementation Of A Remote Audit Tool For High Dose Rate (Hdr) 192ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry, Kevin Casey

Dissertations & Theses (Open Access)

This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The phantom has a single channel capable of accepting all 192Ir HDR brachytherapy sources in current clinical use in the United States. Irradiations were performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, …


Development And Implementation Of The Use Of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms, Jennelle Bergene Aug 2012

Development And Implementation Of The Use Of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms, Jennelle Bergene

Dissertations & Theses (Open Access)

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as …


Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam Aug 2011

Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam

Dissertations & Theses (Open Access)

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy.

Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the …


Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed Tomography Image Sets For Stereotactic Body Radiation Therapy, David A. Zamora Aug 2010

Thoracic Target Volume Delineation Using Various Maximum-Intensity Projection Computed Tomography Image Sets For Stereotactic Body Radiation Therapy, David A. Zamora

Dissertations & Theses (Open Access)

The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations & Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …