Open Access. Powered by Scholars. Published by Universities.®

Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Medical Sciences

Contrast Adaptation In The Lateral Eye Of Limulus Polyphemus, Tchoudomira Valtcheva Nov 2013

Contrast Adaptation In The Lateral Eye Of Limulus Polyphemus, Tchoudomira Valtcheva

USF Tampa Graduate Theses and Dissertations

Luminance and contrast adaptation are neuronal mechanisms that the retina applies for continuous adjustment to light sensitivity though a collection of cellular and synaptic mechanisms distributed across the retinal network, thus accommodating the wide input range of the visual system within the constricted output range of retinal ganglion cells. Luminance mean adaptation has been demonstrated in the output neurons of the invertebrate eye (eccentric cells), and the aim of the study was to investigate whether the homology in visual processing extends to luminance variance (contrast) adaptation as well. The spike trains of individual eccentric cells were recorded from live horseshoe …


Network Dynamics Of Visual Naming, Christopher R. Conner Aug 2013

Network Dynamics Of Visual Naming, Christopher R. Conner

Dissertations & Theses (Open Access)

Recognition and naming of objects and actions are fundamental components of language. They involve several different systems working in coordination to accomplish a complex behavior. During visual naming, sensory and semantic processing are carried out by dedicated cortical substrates in the temporal and occipital lobes, while response selection and articulatory planning are handled by prefrontal cortex. Despite decades of research using lesion analysis, functional MRI and electro-encephalography, the precise dynamics involved remain unknown due to the inadequate spatio-temporal resolution of these methodologies. Of particular interest is the organization of semantic knowledge and the degree of serial and parallel organization of …


Delayed Thrombus Resolution And Fibroproliferative Vascular Wound Healing From Deficiency Of Type Iii Collagen: A Paradoxical Mechanism For Tissue Fragility, Amy J. Reid May 2013

Delayed Thrombus Resolution And Fibroproliferative Vascular Wound Healing From Deficiency Of Type Iii Collagen: A Paradoxical Mechanism For Tissue Fragility, Amy J. Reid

Dissertations & Theses (Open Access)

Vascular Ehlers-Danlos syndrome is a heritable disease of connective tissue caused by mutations in COL3A1, conferring a tissue deficiency of type III collagen. Cutaneous wounds heal poorly in these patients, and they are susceptible to spontaneous and catastrophic rupture of expansible hollow organs like the gut, uterus, and medium-sized to large arteries, which leads to premature death. Although the predisposition for organ rupture is often attributed to inherent tissue fragility, investigation of arteries from a haploinsufficient Col3a1 mouse model (Col3a1+/-) demonstrates that mutant arteries withstand even supraphysiologic pressures comparably to wild-type vessels. We hypothesize that injury …


Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead May 2013

Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead

UNLV Theses, Dissertations, Professional Papers, and Capstones

The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …


The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood Jan 2013

The Effects Of Hydrostatic Pressure On Early Endothelial Tubulogenic Processes, Ryan M. Underwood

Theses and Dissertations--Biomedical Engineering

The effects of mechanical forces on endothelial cell function and behavior are well documented, but have not been fully characterized. Specifically, fluid pressure has been shown to elicit physical and chemical responses known to be involved in the initiation and progression of endothelial cell-mediated vascularization. Central to the process of vascularization is the formation of tube-like structures. This process—tubulogenesis—is essential to both the physiological and pathological growth of tissues. Given the known effects of pressure on endothelial cells and its ubiquitous presence in the vasculature, we investigated pressure as a magnitude-dependent parameter for the regulation of endothelial tubulogenic activity. To …


Design, Manufacturing, And Assembly Of A Flexible Thermoelectric Device, Christopher Anthony Martinez Jan 2013

Design, Manufacturing, And Assembly Of A Flexible Thermoelectric Device, Christopher Anthony Martinez

USF Tampa Graduate Theses and Dissertations

This thesis documents the design, manufacturing, and assembly of a flexible thermoelectric device. Such a device has immediate use in haptics, medical, and athletic applications. The governing theory behind the device is explained and a one dimensional heat transfer model is developed to estimate performance. This model and consideration for the manufacturing and assembly possibilities are the drivers behind the decisions made in design choices. Once the design was finalized, manufacturing methods for the various components were explored. The system was created by etching copper patterns on a copper/polyimide laminate and screen printing solder paste onto the circuits. Thermoelectric elements …


Functional Near Infrared Detection Of Real And Imagined Finger Taps Using Support Vector Machine, Linear Discriminant Analysis, And Decision Tree Classification Methods, Eugene A. Stoudenmire Jan 2013

Functional Near Infrared Detection Of Real And Imagined Finger Taps Using Support Vector Machine, Linear Discriminant Analysis, And Decision Tree Classification Methods, Eugene A. Stoudenmire

Computational Modeling & Simulation Engineering Theses & Dissertations

This study investigates the thesis that given cerebral response samples of an individual's left, right, both, and imagined finger tapping, continuous wave (CW) functional Near Infrared (fNIR), unregistered with fMRI, can differentiate between any two of the four categories.

Fifty subjects were outfitted with a single source/detector attached to a single, square pad, affixed to their heads using devices such as elastic bands and caps for light shielding. Slides depicting arrows pointing left, right, both directions, or made of dashed lines were presented to each subject, with a slide of text interspersed between each. Subjects tapped with their left finger, …


Impedance Changes In Biceps Brachii Due To Isometric Contractions And Muscle Fatigue Using Electrical Impedance Myography (Eim), Travis Orth Jan 2013

Impedance Changes In Biceps Brachii Due To Isometric Contractions And Muscle Fatigue Using Electrical Impedance Myography (Eim), Travis Orth

Electronic Theses and Dissertations

Electrical impedance myography (EIM) is a non-invasive technique used to evaluate neuromuscular conditions by using a quantitative parameter called impedance (Z). It relies upon the application and measurement of high-frequency, low-intensity electrical current imbedded over a localized muscle to determine its opposition to current flow. In brevity, impedance determines the resistance of muscle fibers due to changes in muscle composition. The objective of this thesis was to establish a relationship between muscles at rest and during isometric contractions at various force levels(25%, 50%, and 100% of maximum voluntary contraction) of the biceps brachii over a multifrequency spectrum. Impedance measurements due …