Open Access. Powered by Scholars. Published by Universities.®

Medical Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Medical Sciences

Validation Of Minimally-Invasive Sample Collection Methods For Measurement Of Telomere Length, Stephanie A. Stout, Jue Lin, Natalie Hernandez, Elyssia Poggi Davis, Judith E. Carroll, Laura M. Glynn Dec 2017

Validation Of Minimally-Invasive Sample Collection Methods For Measurement Of Telomere Length, Stephanie A. Stout, Jue Lin, Natalie Hernandez, Elyssia Poggi Davis, Judith E. Carroll, Laura M. Glynn

Psychology Faculty Articles and Research

Objective: The discovery of telomere length (TL) as a biomarker of cellular aging and correlate of age-related disease has generated a new field of research in the biology of healthy aging. Although the most common method of sample collection for TL is venous blood draw, less-invasive DNA collection methods are becoming more widely used. However, how TL relates across tissues derived from these sample collection methods is poorly understood. The current study is the first to characterize the associations in TL across three sample collection methods: venous whole blood, finger prick dried blood spot and saliva.

Methods: TL …


Development Of Fetal Movement Between 26 And 36 Weeks’ Gestation In Response To Vibroacoustic Stimulation, Marybeth Grant-Beuttler, Laura M. Glynn, Amy L. Salisbury, Elyssia Poggi Davis, Carol Holliday, Curt A. Sandman Jan 2011

Development Of Fetal Movement Between 26 And 36 Weeks’ Gestation In Response To Vibroacoustic Stimulation, Marybeth Grant-Beuttler, Laura M. Glynn, Amy L. Salisbury, Elyssia Poggi Davis, Carol Holliday, Curt A. Sandman

Psychology Faculty Articles and Research

BACKGROUND: Ultrasound observation of fetal movement has documented general trends in motor development and fetal age when motor response to stimulation is observed. Evaluation of fetal movement quality, in addition to specific motor activity, may improve documentation of motor development and highlight specific motor responses to stimulation.

AIM: The aim of this investigation was to assess fetal movement at 26 and 36-weeks gestation during three conditions (baseline, immediate response to vibro-acoustic stimulation (VAS), and post-response).

DESIGN: A prospective, longitudinal design was utilized.

SUBJECTS: Twelve normally developing fetuses, eight females and four males, were examined with continuous ultrasound imaging.

OUTCOME MEASURES: …