Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

2024

Discipline
Institution
Keyword
Publication
Publication Type

Articles 31 - 48 of 48

Full-Text Articles in Prosthodontics and Prosthodontology

Minimally Invasive Periodontal Regeneration With The Buccal Approach: A Systematic Review And Meta-Analysis Of Clinical Studies, Elisa Pasqualini, Filipe Castro, Denise Curado, Ana Martelete, Artak Heboyan, Muhammad H. Saleh, Juliana Campos Hasse Fernandes, Gustavo Fernandes Jan 2024

Minimally Invasive Periodontal Regeneration With The Buccal Approach: A Systematic Review And Meta-Analysis Of Clinical Studies, Elisa Pasqualini, Filipe Castro, Denise Curado, Ana Martelete, Artak Heboyan, Muhammad H. Saleh, Juliana Campos Hasse Fernandes, Gustavo Fernandes

MOSDOH Faculty Publications

OBJECTIVE: The aim of this study was to investigate clinical periodontal parameters after treatment using the Minimally Invasive Surgical Technique (MIST), Modified Minimally Invasive Surgical Technique (M-MIST), and/or any technique for papilla preservation, such as Entire Papilla Preservation (EPP), modified-papilla preservation technique (M-PPT), or simplified-papilla preservation technique (SPPT). METHODS: The focus question was “For patients with periodontal intrabony defects (P), what is the best minimally invasive regenerative approach (I), comparing MIST, M-MIST, and papilla preservation techniques’ outcomes (C) to improve PD, CAL, GR, and periodontal stability (O)?” An online search was conducted on PubMed, Cochrane Library, and Embase. Only randomized …


Is The Facial Bone Wall Critical To Achieving Esthetic Outcomes In Immediate Implant Placement With Immediate Restoration? A Systematic Review, Sergio Charifker Ribeiro Martins, Marcio Da Costa Marques, Michael Gomes Vidal, Pedro Henrique Moreira Paulo Tolentino, Roberto Galvão Dinelli, Gustavo Fernandes, Jamil Awad Shibli Jan 2024

Is The Facial Bone Wall Critical To Achieving Esthetic Outcomes In Immediate Implant Placement With Immediate Restoration? A Systematic Review, Sergio Charifker Ribeiro Martins, Marcio Da Costa Marques, Michael Gomes Vidal, Pedro Henrique Moreira Paulo Tolentino, Roberto Galvão Dinelli, Gustavo Fernandes, Jamil Awad Shibli

MOSDOH Faculty Publications

Background. Rehabilitation in the anterior region requires specific conditions for success, such as the presence of papilla, emergence profile, and balance between pink and white esthetic. Objectives. This systematic review aimed to evaluate the esthetic risk associated with immediate implant placement with immediate restoration in the anterior superior area, where the facial bone plate may be absent or deficient. Materials and methods. The search was done in PubMed, Embase, Cochrane, Lilacs, Scopus, Scielo, and Google Scholar databases. The investigation involved clinical studies and observational studies published between January 2012 and July 2023. Studies were excluded if there was less than …


Critical-Size Defects Reconstruction With Four Different Bone Grafts Associated With E-Ptfe Membrane: A Histomorphometric Experimental In Vivo Study, Gustavo Fernandes, Filipe Castro, Rafael Martins Pereira, Wendel Teixeira, Sergio Gehrke, Julio Cesar Joly, Juan Blanco Carrion, Juliana Campos Hasse Fernandes Jan 2024

Critical-Size Defects Reconstruction With Four Different Bone Grafts Associated With E-Ptfe Membrane: A Histomorphometric Experimental In Vivo Study, Gustavo Fernandes, Filipe Castro, Rafael Martins Pereira, Wendel Teixeira, Sergio Gehrke, Julio Cesar Joly, Juan Blanco Carrion, Juliana Campos Hasse Fernandes

MOSDOH Faculty Publications

Objectives: The goal of this study was to assess the newly formed bone and the remnant biomaterial by comparing four different bone grafts used to treat critical-size defects, associated or not with the non-resorbable membrane.

Materials and methods: Two calvaria critical-size bone defects were created in 50 male Wistar rats. They were divided into blood (G1), autogenous (G2), bioglass (G3), hydroxyapatite (G4), and xenograft (G5) groups, associated or not with e-PTFE. The experimental periods were 15 and 45 days. Sections were prepared for histomorphometric assessment. All data were analyzed by the mixed-effects model with multiple comparisons (significance level, p < .05).

Results: …


Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected] Jan 2024

Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]

Future Dental Journal

Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected] Jan 2024

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected]

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …


Effect Of Different Surface Characterizations On Color Stability And Surface Roughness Of Provisional Materials After Toothbrushing, Sarasinee Sattawatthamrong Jan 2024

Effect Of Different Surface Characterizations On Color Stability And Surface Roughness Of Provisional Materials After Toothbrushing, Sarasinee Sattawatthamrong

Chulalongkorn University Theses and Dissertations (Chula ETD)

This study aimed to evaluate the surface roughness of 5 provisional materials with different surface characterization methods after simulating 1 year of toothbrushing. Specimens were fabricated from autopolymerized polymethyl methacrylate (UNIFAST Trad), autopolymerized bis-acryl composite resin (Protemp 4), light-activated composite resin (REVOTEK LC), milled polymethyl methacrylate block (DD provi P HI), and 3-dimensionally printed methacrylate oligomer (Nextdent C&B MFH). Each material was divided into 3 groups: polishing, application of Lite Art and Resin Glaze, and application of OPTIGLAZE color. After 5,000 and 10,000 toothbrushing cycles, surface roughness was measured. A 3-way repeated measures ANOVA was conducted to analyze the effects …


The Effect Of Cement Thickness On Shear Bond Strength Of Zirconia With Three Different Self-Adhesive Resin Cements, Thofun Ieamsuwantada Jan 2024

The Effect Of Cement Thickness On Shear Bond Strength Of Zirconia With Three Different Self-Adhesive Resin Cements, Thofun Ieamsuwantada

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: This study aimed to evaluate the influence of resin cement thickness on the shear bond strength (SBS) to zirconia using different self-adhesive resin cements (SAC). Materials and Methods: One hundred twenty irconia specimens were prepared, air abraded with 50 μm aluminium oxide particles and divided into 12 groups (n  = 10), according to the cement thickness (50, 100, 150, and 200 μm) and SAC (RelyXTM U200, PANAVIATM SA LUTING Multi, MaxcemTM Elite Chroma). The specimens were cemented to resin composite blocks with SAC, stored in water at 37°C for 24 hours and subjected to the SBS test. Mode of …


Effect Of Chairside Silicone Polishing Systems On The Surface Roughness Of Cad/Cam Milled And Conventional Denture Base Materials, Sarita Apiromwijit Jan 2024

Effect Of Chairside Silicone Polishing Systems On The Surface Roughness Of Cad/Cam Milled And Conventional Denture Base Materials, Sarita Apiromwijit

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose: The objective of this study was to evaluate the effect of two commercial chairside polishing systems compared with conventional laboratory polishing on the surface roughness of two types of denture base materials. Methods: Square-shaped specimens (8x8x5 mm) were fabricated from CAD/CAM milled and heat-polymerized denture base materials. Each specimen was ground with tungsten carbide and then divided into three groups according to polishing techniques(n=8): Exa technique, AcryPoint, and conventional laboratory polishing. The roughness (Ra) values were measured using a non-contact profilometer after finishing with tungsten carbide bur, every 30 seconds with each subsequent polisher (rough, medium, and fine) of …


The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat Jan 2024

The Study On Surface Roughness And Corrosion Resistance Of Electropolished Laser Powder Bed Fusion Ti-6al-4v Eli Alloy, Venus Chatpaiboonwat

Chulalongkorn University Theses and Dissertations (Chula ETD)

The Ti6Al4V ELI alloy produced via Laser Powder Bed Fusion (L-PBF) has drawn interest for usage in dental applications. However, surface finishing is an important property that can be managed by various methods. The purpose of this study was to investigate the effects of electropolishing (EP) on the surface roughness and corrosion resistance of L-PBF Ti6Al4V ELI alloy. The present study explored the influence of current density, voltage, and distance on the surface quality and corrosion behavior. The results showed that EP significantly reduced the surface roughness and enhanced corrosion resistance of printed Ti6Al4V ELI alloy with the best result …


Adaptation Of Conventional Versus Digitally Fabricated Auricular Prosthesis: A Randomized Clinical Trial, Sara Fikry, Fatma Mohei El Mogei Dr, Mohamed El Khashab Prof, Amal Rekabi Prof Jan 2024

Adaptation Of Conventional Versus Digitally Fabricated Auricular Prosthesis: A Randomized Clinical Trial, Sara Fikry, Fatma Mohei El Mogei Dr, Mohamed El Khashab Prof, Amal Rekabi Prof

Dentistry

Aim: This study aimed to compare digitally fabricated auricular prostheses to conventional prostheses, regarding adaptation to defect site in patients with auricular defects.

Subjects and methods: Fifteen patients were recruited for auricular prosthetic reconstruction. Endosseous implants were placed, then patients were assigned into two groups. In control group, ear models were processed on stone cast obtained from conventional impression. In intervention group, computed tomography and optical scanning were combined to obtain a virtual model with digital analogues over which ear models were designed and printed. Ear models of both groups were seated, and adaptation was measured on the patient using …


Creating Smiles With Digital Workflow And Matrix Transfer Technique In Customizing Personality-Based Smile Designing, Jahnavi Purna Gorripati, Surekha Godbole Jan 2024

Creating Smiles With Digital Workflow And Matrix Transfer Technique In Customizing Personality-Based Smile Designing, Jahnavi Purna Gorripati, Surekha Godbole

International Arab Journal of Dentistry

Introduction: This report is a presentation of a clinical case that follows the Visagism concept for 2D planning and, CAD (Exo CAD) for 3D desiging along 3D printed diagnostic wax-up model for closure of anterior spacing.

Case presentation: A 24-year-old man presented with midline diastema and anterior spacing 11-13, 21-23 and wants a smile designed. This concern was solved following a smile design (VisagiSMile) planning digitally for diagnostic wax and printing a 3D model. The matrix transfer technique has been used to directly convey planned information from 3D-printed diagnostic wax-up to definitive restorations.

Conclusions: In this day …


Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi Jan 2024

Testing The Strength Of Thin Feather-Edge Monolithic Multilayered Zirconia Crowns: A Pilot Study With A Novel Acoustic Test, Estelle Saab, Camille Haddad, Maher Abboud, Maha Daou, Amine Zoghbi

International Arab Journal of Dentistry

Introduction: Limited research has explored the mechanical characteristics of recently introduced multilayered monolithic zirconia (MZC) crowns with feather-edge margins design. Moreover, most of the conventional techniques for evaluating the mechanical behavior of brittle dental ceramics rely on destructive tests, making it impossible to precisely evaluate real strength values due to premature crack initiation detection failure.

Objectives: The main objective of the study was to assess the load capacity of translucent multilayered monolithic zirconia crowns with feather-edge margin thicknesses of 0.4 mm and 0.5 mm. Additionally, the research introduced a novel non-destructive acoustic emission testing (AET) technique in the …


Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme Jan 2024

Investigation Of Fracture Resistance With Different Diameters Of Polyetherketoneketone Post And Core Materials: A Pilot Study, Maya Kabbara, Ryan Harouny, Habib Rahme

International Arab Journal of Dentistry

Objectives: The primary objective of this study is to investigate the resistance to fracture of Polyetherketoneketones PEKK, used as post and core by fabrication in different diameters in the canal, and comparing the test results for each group.

Methods: Thirty extracted mandibular premolars were selected, endodontically treated and prepared to receive the post and cores milled from polyetherketoneketone disk. The specimens were randomly divided into five groups (n = 6) respectively: group 1 received pekk post with diameter = 0.70 mm, group 2 received pekk post with diameter = 0.90 mm, group 3 received pekk post with diameter …


Clinical Outcomes Of Primary Anterior Esthetic Crowns In Pediatric Dentistry, Jenan Alahmad Jan 2024

Clinical Outcomes Of Primary Anterior Esthetic Crowns In Pediatric Dentistry, Jenan Alahmad

Theses and Dissertations

Clinical Outcomes of Primary Anterior Esthetic Crowns in Pediatric Dentistry - A Prospective Cohort Study

By: Jenan Alahmad, BDS

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.

Virginia Commonwealth University, 2024

Thesis Advisor: Parthasarathy Madurantakam, DDS, MDS, PhD

Department of Pediatric Dentistry

BODY

Purpose: This prospective cohort study aimed to compare the effectiveness of restoring maxillary anterior teeth in children (aged 3-6 years) with three different materials: Zirconia Crowns (ZC), Resin Composite Crowns (RC), and Pre-veneered Stainless-Steel Crowns (PVSSC). The study aims to assess the Oral …


การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์ Jan 2024

การศึกษาการสึกระหว่างโคบอลต์โครเมียมและวัสดุเซรามิกที่ใช้ในงานทันตกรรมดิจิตอล, มรกต ไทยรัตน์

Chulalongkorn University Theses and Dissertations (Chula ETD)

วัตถุประสงค์: ทำการศึกษาสภาวะจำลองเพื่อวัดการสูญเสียปริมาตรจากการสึกหลังจากจำลองการขัดถู 250,000 รอบของโลหะผสมโคบอลต์โครเมียม (CoCr) กับวัสดุที่ใช้ทำการบูรณะฟันหลักห้าชนิด วัสดุและวิธีการ: เตรียมตัวอย่างทดสอบตัดเป็นสี่เหลี่ยมจำนวนชนิดละ 8 ชิ้น (5 x 5 x 2 มิลลิเมตร) จากโลหะผสมที่ไม่มีทองผสม (NP), ลิเธียมไดซิลิเกต (EM) เธียมไดซิลิเกตเสริมความแข็งแรง (TR) เซรามิคที่มีเรซินเป็นฐาน (CM) และเซอร์โคเนีย (ZR) ตัวอย่าง EM TR และ ZR ได้รับการเผาตามคำแนะนำของผู้ผลิต แท่งโลหะผสมโคบอลต์โครเมียมสร้างขึ้นโดยการหล่อโลหะแบบไล่ขี้ผึ้ง จำลองการสึกแบบสององค์ประกอบด้วยเครื่องจำลองการสึกจากการขัดถู จำนวน 250,000 รอบ วัดการสูญเสียปริมาตรของชิ้นงานทดสอบโดยใช้เครื่องวัดความหยาบพื้นผิว การสูญเสียปริมาตรของแท่งโลหะผสมคำนวณโดยการความยาวที่ลดลงและรัศมีของพื้นที่ที่เกิดบริเวณที่สึก วิเคราะห์ข้อมูลทางสถิติโดยใช้ MANOVA (pNP>ZR) การสูญเสียปริมาตรของแท่งโลหะหลังการสึกในกลุ่ม CM น้อยกว่าในกลุ่ม EM และ NP ในขณะที่กลุ่มอื่น ๆ ไม่มีความแตกต่างกันอย่างมีนัยสำคัญ


Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared Jan 2024

Comparison Of The Failure Between Conventional Pmma And Milled Pmma Full Arch Maxillary Interim Prosthesis Fixed On 4 Implants: An In Vitro Study, Tatiana Bou Sakr, Hani Tohme, Natalia Bou Sakr, Victor Ghoubril, Carole Abi Ghosn Yared

International Arab Journal of Dentistry

Objectives: The principal objective of this study was to compare the failure load between the conventional heat polymerized PMMA and the CAD/CAM milled PMMA interim full arch implant prostheses. The secondary aim was to evaluate the success of the distal extension of the temporary PMMA prosthesis.

Methods: A metallic edentulous upper arch model with 4 Straumann screw-retained abutment digital analogs was used to create 15 specimens for each of the 2 groups: Conventional and milled. Failure load was measured on 5 different regions on the left and right side of each specimen with the YLE universal testing machine: …


Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah Jan 2024

Endocrown, From Preparation To Bonding: Case Report, Amira Yousfi, Rihab Dakhli, Jilani Saafi, Belhassen Harzallah

International Arab Journal of Dentistry

The restoration of endodontically treated teeth is a real challenge, particularly teeth with extensively damaged coronal tissues. The use of post-retained restorations has been discussed because of the potential tooth weakening due to the additional removal of sound dental structures. In fact, long-term prognosis of a devitalized tooth is closely related to the coronal restoration’s quality and the remaining dental structure. With the development of adhesive dentistry and minimally invasive preparation, new approaches have emerged. Among them, the endocrown which is monolithic ceramic bonded restoration, anchored to the internal portion of pulp chamber and cavity margins that have been used …


Implant Overdenture Abutment Loosening Under Hyperbaric Conditions, Zana Jamal Al-Saloum Jan 2024

Implant Overdenture Abutment Loosening Under Hyperbaric Conditions, Zana Jamal Al-Saloum

Graduate Theses, Dissertations, and Problem Reports (ETD)

Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments.

The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive.

Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were …