Open Access. Powered by Scholars. Published by Universities.®

Prosthodontics and Prosthodontology Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 31 - 60 of 65

Full-Text Articles in Prosthodontics and Prosthodontology

Accuracy And Repeatability Of Different Intraoral Instruments On Shade Determination Compared To Visual Shade Selection, Omar Elsergany Jan 2022

Accuracy And Repeatability Of Different Intraoral Instruments On Shade Determination Compared To Visual Shade Selection, Omar Elsergany

Dentistry

Objective: To evaluate the accuracy and repeatability of intraoral instruments used for shade determination compared to visual shade selection (VSS). Materials and Methods: A total of 20 subjects and 10 observers, balanced by gender, participated in the study. Observers performed VSS of the upper right central incisor from each subject. Instrumental shade determination of the same teeth was performed using a spectrophotometer (Easyshade V) and intraoral scanners (CEREC Omnicam, Primescan, Trios 3 and Trios 4). Vita Classical shade nomenclature was used to record the shade designation for all instruments and VSS. The accuracy of the instruments was determined by comparing …


An In Vitro Evaluation Of Surface Roughness, Color Stability And Bacterial Accumulation Of Lithium Disilicate Ceramic After Prophylactic Periodontal Treatment, Fatma Makkeyah, Tarek Salah Morsi, Marwa Mohamed Wahsh, Amr Saleh El-Etreby Jan 2021

An In Vitro Evaluation Of Surface Roughness, Color Stability And Bacterial Accumulation Of Lithium Disilicate Ceramic After Prophylactic Periodontal Treatment, Fatma Makkeyah, Tarek Salah Morsi, Marwa Mohamed Wahsh, Amr Saleh El-Etreby

Dentistry

Objective: To evaluate the effect of scaling procedures using different ultrasonic tips on the surface roughness, color stability and bacterial accumulation of lithium disilicate ceramic. Material and Methods: Scaling procedure was carried out using ultrasonic scaler (Satalec, Acteon, North America) with stainless-steel tip (US), titanium tip (UT) and plastic tip (UP), on disc shaped lithium disilicate samples cemented into a cavity prepared onto the labial surface of freshly extracted bovine teeth (10 samples per group). The samples were stored in coffee solution in an incubator at 37°C for 12 days, which is equivalent to 1 year of coffee consumption. The …


The Effect Of Different Drilling Protocols On Bone Healing Around Dental Implants., Sara Fikry, Amr Amin Ghanim, Hisham El Sheikh, Omar El Sergany Jan 2021

The Effect Of Different Drilling Protocols On Bone Healing Around Dental Implants., Sara Fikry, Amr Amin Ghanim, Hisham El Sheikh, Omar El Sergany

Dentistry

Materials and Methods: 20 patients with kennedy class III modification 1 edentulous areas were recruited for this study and divided into two groups; Control group received implants with conventional osteotomy preparation following standard drilling protocol (speed= 1200 rpm) with torque of 30N and sufficient saline irrigation, while Study group received implants with osteotomy preparation following a low speed drilling protocol (speed < 200 rpm) without irrigation and a torque of 50 N. Cone Beam CT was used to evaluate bone height and density around the implants at 3, 6 and 12 months after insertion. Implant primary stability was evaluated using Ostell by Resonance Frequency Analysis. Results The results showed no significant difference between bone height changes and densities in the control and study groups. Implants primary stability also showed no significant difference in ISQ values between both groups. Conclusion Biologic drilling is a promising implant drilling protocol with a potential to insert implants showing successful osseointegration and acceptable bone changes.


Pre-Heating Of Dual-Polymerized Resin Core Foundation System: Effect On Micro-Shear Bond Strength, Degree Of Conversion And Ultimate Tensile Strength, Sara Adel Botros Jan 2021

Pre-Heating Of Dual-Polymerized Resin Core Foundation System: Effect On Micro-Shear Bond Strength, Degree Of Conversion And Ultimate Tensile Strength, Sara Adel Botros

Dentistry

This study evaluated the effect of pre-heating a dual-polymerized adhesive and a dual-polymerized core build-up resin composite on their dentin micro-shear bond strength (mSBS), degree of conversion (DC%) and ultimate tensile strength (UTS). For mSBS, 45 human molars were divided into 9 groups (n ¼ 5) according to two factors: (1) Adhesive temperature (25 C/32 C/40 C) and 2- Resin composite temperature (25 C/32 C/40 C). Dual-polymerized adhesive (Futurabond U/FBU) was applied over occlusal dentin at each temperature following the manufacturer’s instructions. Four dual-polymerized composites (Rebilda DC/RDC, VOCO) micro-cylinders (1.2 mm diameter 1 mm height) were built-up over each dentin …


Flexure Strength Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites: Effect Of Material Thickness And Distance To Photo-Polymerization Device., Sara Adel Botros Jan 2021

Flexure Strength Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites: Effect Of Material Thickness And Distance To Photo-Polymerization Device., Sara Adel Botros

Dentistry

This study evaluated the effect of thickness and photo-polymer- ization distance on flexure strength of two bulk fill resin compo- sites. In total, 96 rectangular-shaped resin composite bars were divided into eight experimental groups (n ¼ 12/group) according to the three experimental factors; Factor 1: Material (X-tra fil and Admira Fusion X-tra), Factor 2: Thickness (2 mm and 4 mm) and Factor 3: photo-polymerization distance (2 mm and 8 mm). The bars were prepared with fixed 2 mm width and 2 mm length but differed in thickness (2 mm or 4 mm). The bars were light cured either at 2 …


Cad/Cam Milling Versus Rapid Prototyping Surgical Guide Techniques In Dental Implant Placement, Fardos N. Rizk Prof., Marwa Sabet Prof., Hebatallah Mohammed, Adham Elghamry Jul 2020

Cad/Cam Milling Versus Rapid Prototyping Surgical Guide Techniques In Dental Implant Placement, Fardos N. Rizk Prof., Marwa Sabet Prof., Hebatallah Mohammed, Adham Elghamry

Dentistry

No abstract provided.


Preheating-Temperature Affects Nanoleakage And Degree Of Conversion Of Dual-Cured Adhesive/Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Zainab Diaa Soliman, Dalia Ibrahim El-Korashy May 2020

Preheating-Temperature Affects Nanoleakage And Degree Of Conversion Of Dual-Cured Adhesive/Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Zainab Diaa Soliman, Dalia Ibrahim El-Korashy

Dentistry

No abstract provided.


Effect Of Surface Treatment And Storage Time On Immediate Repair Bond Strength Durability Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites., Sara Adel Botros Jan 2020

Effect Of Surface Treatment And Storage Time On Immediate Repair Bond Strength Durability Of Methacrylate- And Ormocer-Based Bulk Fill Resin Composites., Sara Adel Botros

Dentistry

The aim of this study was to evaluate the effect of surface treatment and storage time on immediate repair bond durability of methacrylate- and ormocer-based bulk fill composites. In total, 265 discs were divided into 32 groups (n = 8/group) according to: (1) Material: X-tra fil and Admira Fusion X-tra; (2) Surface treatment: oxygen inhibition; matrix; Futurabond M+; Silane/Futurabond M+; Admira Bond; Silane/Admira Bond; ceramic repair system; and Silane/Cimara bond; and (3) Storage time: 24 h and 6 months. Each disc received three micro-cylinders from the same material. Specimens were subjected to micro-shear bond strength testing either at 24 h …


Radiographic Bone Changes Surrounding Implants Of Different Attachment Systems., Sara Fikry El Shafei Dr, Fardos N Rizk Prof Jan 2020

Radiographic Bone Changes Surrounding Implants Of Different Attachment Systems., Sara Fikry El Shafei Dr, Fardos N Rizk Prof

Dentistry

This study was conducted to compare the effect of GPS attachment, OT Equator attachment and Ball and Socket attachment on crestal bone around implants in implant retained mandibular overdenture cases. Materials and Methods: Following two stage surgical protocol eighteen completely edentulous patients received two implants placed bilaterally in the canine region (36 implants) to retain mandibular overdentures. Inclusion Criteria: Patients were all healthy men, non-smokers, Following Misch rules of bone classification patients with bone density ranging from 850-1250 HU (D2) and bone height and width more than 10 mm and 5 mm respectively. Four months following the surgery patients were …


Comparative Study Of Two Fifferent Telescopic Crown Materials Retaining Lower Partial Overdenture, Fardos N. Rizk Prof., Ayman Hany Amin Dr., Gehan Fikry Prof., Amr Ismail Dr. Jan 2020

Comparative Study Of Two Fifferent Telescopic Crown Materials Retaining Lower Partial Overdenture, Fardos N. Rizk Prof., Ayman Hany Amin Dr., Gehan Fikry Prof., Amr Ismail Dr.

Dentistry

Background and Objective: This study was conducted to measure the difference between Chrome Cobalt telescopic crowns and Poly ether ether ketone (PEEK) telescopic crowns retaining implant retained partial overdenture.

Materials and Methods: This is a comparitive study that included fourteen lower kennedy class I partially edendulous patients. All patients received posterior implant in the second molar area in each side. The patients were divided into 2 groups, the first group received chrome cobalt telescopic crown and the second group received poly ether ketone telescopic crowns over the implants. Partial overdenture was constructed for all the patients in the two groups. …


The Effect Of Framework Material On Partial Overdenture Supporting Structure, Sara Fikry El Shafei Jan 2019

The Effect Of Framework Material On Partial Overdenture Supporting Structure, Sara Fikry El Shafei

Dentistry

Purpose: In this study the effect of two partial denture framework materials on the bone tissues surrounding a the implants, in an implant retained partial overdenture is compared. Materials and Mehods: 12 partially edentulous patients with mandibular kennedy class I configuration were selected for this study. They were divided into two groups; Group 1 received a mandibular implant retained partial overdentures with a framework made of cobalt chromium. Group 2 received implant retained partial overdentures with a framework made of acetal resin. The results were evaluated using cone beam ct. Results: The results showed that bone changes produced in metallic …


Effect Of Pre-Heating Temperatures On Microshear Bond Strength And Degree Of Conversion Of A Dual-Cured Resin Core Foundation, Sara Adel Botros Jan 2019

Effect Of Pre-Heating Temperatures On Microshear Bond Strength And Degree Of Conversion Of A Dual-Cured Resin Core Foundation, Sara Adel Botros

Dentistry

Aim: To evaluate the effect of pre-heating temperatures of a dual-cured adhesive and a dualcured resin composite as well as tubule orientation on micro-shear bond strength (µSBS) to dentin. The degree of conversion (DC%) of the adhesive and the composite was also evaluated at the different temperatures. Materials and Methods: For µSBS, 90 human molars were randomly divided into 18 groups (n=5) according to the three experimental factors. Factor 1: Adhesive temperature, Factor 2: Resin composite temperature; and Factor 3: Tubule orientation (occlusal or axial). Adhesive and composite temperatures were set at 25ºC, 32ºC and 40ºC. The adhesive was applied …


Osseointegrated Implants Versus Zirconium Mucosal Inserts In Complete Denture Patients, Sara Fikry El Shafei Dr, Fardos N Rizk Jan 2019

Osseointegrated Implants Versus Zirconium Mucosal Inserts In Complete Denture Patients, Sara Fikry El Shafei Dr, Fardos N Rizk

Dentistry

Purpose: To evaluate the effect of osseointegrated implants versus mucosal inserts used for retention of complete dentures. Materials and Methods: Twelve completely edentulous patients were selected for this study and divided into two groups of six. Group I received implant retained maxillary overdentures, while group II received maxillary overdentures retained by muchor zirconium mucosal inserts. Bone changes in both groups were evaluated using cone beam ct at insertion and after six and twelve months. Results: The results showed that the bone changes produced in mucosal overdenture wearers were greater than those produced in implant overdenture wearers. Conclusion: Zirconium mucosal inserts …


Deviation Between Planned And Actual Implant Positions Inserted Using Mucosa-Supported Stereolithographic Surgical Guide In Edentulous Mandible And Maxilla, Fardos N. Rizk, Marwa Sabet Prof., Omar Yehia Jan 2019

Deviation Between Planned And Actual Implant Positions Inserted Using Mucosa-Supported Stereolithographic Surgical Guide In Edentulous Mandible And Maxilla, Fardos N. Rizk, Marwa Sabet Prof., Omar Yehia

Dentistry

Purpose: estimate the deviation between the planned and the actual implant inserted using a mucosa-supported stereolithographic surgical guide in different edentulous arches and determine the effect of the arch (mandible or maxilla) on accuracy. Materials and Methods: 16 implants were placed in completely edentulous arches and divided into two groups. Group (A): Eight implants were placed in four patients in the mandible using completely limiting mucosa-supported stereolithographic (SLA) surgical guide during implant insertion. Two implants were placed in each patient intraforamina. Group (B): Eight implants were placed in Two patients in the maxilla using completely limiting mucosa-supported stereolithographic (SLA) surgical …


Short Length Versus Conventional Implants In Rehabilitation Of Completely Edentulous Mandible, Fardos N. Rizk, Engy Tallat, Mahmoud Elhomossany, Ahmed Lasheen Dr., Hebatalla Mahmoud Jan 2018

Short Length Versus Conventional Implants In Rehabilitation Of Completely Edentulous Mandible, Fardos N. Rizk, Engy Tallat, Mahmoud Elhomossany, Ahmed Lasheen Dr., Hebatalla Mahmoud

Dentistry

Various bone augmentation strategies have been proposed to overcome the anatomic and physiologic limitations of implant placement in patients with atrophic edentulous ridges. The use of short implants may provide an alternative treatment to avoid complications associated with alveolar bone augmentation. However, the clinical effectiveness of short implants versus long implants was not thoroughly investigated. Marginal bone height changes around short and conventional implants were evaluated in this study Methods: Fourteen completely edentulous male patients were selected and divided into two equal groups. Group (I) Patients received conventional complete maxillary dentures opposed by mandibular overdentures supported and retained by two …


Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr. Jan 2017

Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr.

Dentistry

Introduction: Severely atrophied mandibles are a common problem within elderly completely edentulous patients. Given their small diameters, long height and self-tapping characteristics, miniimplant retained over-dentures are a valuable treatment option in such patients. Mini-implants are usually once-piece implants, however recently two-piece mini-implants were introduced with aim of addressing the angulation problems. The success of the latter has not been thoroughly studied. Crestal bone height measurements are normally used to evaluate implant success. Therefore this study was conducted to evaluate the effect of one piece versus two piece ERA mini implants on crestal bone height of implant retained mandibular over-denture. Materials …


Mucosa-Supported Stereolithographic Surgical Guide Versus Conventional Surgical Stent In Implant Supported Overdenture, Fardos N. Rizk, Marwa Sabet Prof., Shaimaa Azoz, Eman Gamal Jan 2017

Mucosa-Supported Stereolithographic Surgical Guide Versus Conventional Surgical Stent In Implant Supported Overdenture, Fardos N. Rizk, Marwa Sabet Prof., Shaimaa Azoz, Eman Gamal

Dentistry

Purpose: The aim of the study was to compare between the accuracy of mucosa-supported stereolithographic surgical guide versus conventional surgical stent in implant supported overdenture. Materials and methods: Twelve patients with completely edentulous patients were selected for this study and divided into three groups. Group (A): 8 implants were placed in the mandible using conventional surgical stents during implant insertion. Group (B): 8 implants were placed in the mandible using partially limiting mucosa-supported stereolithographic (SLA) surgical guide during implant insertion. Group (C): 8 implants were placed in the mandible using completely limiting mucosa-supported stereolithographic (SLA) surgical guide during implant insertion. …


Study Retention And Physical Properties Of Conventional And Microwave-Cured Acrylic Resin Complete Denture: An In-Vivo And In-Vitro Investigation, Fardos N. Rizk, Amany Elhadary Oct 2016

Study Retention And Physical Properties Of Conventional And Microwave-Cured Acrylic Resin Complete Denture: An In-Vivo And In-Vitro Investigation, Fardos N. Rizk, Amany Elhadary

Dentistry

Aim: This study was two folded: an in-vivo study to compare the retentive properties of Lucitone conventional cured denture base resin and Nature-Cryl MC microwave cured denture base resin and an in-vitro study to compare the internal adaptation, fracture resistance, roughness, hardness and colour stability of these two materials and correlate the laboratory results with each other and with the clinical results. Materials and Methods: Twenty completely edentulous male patients received twenty complete dentures constructed from Lucitone conventional cured denture base resin. The retentive properties of the upper complete dentures were measured using force measurement gauge at one week, one …


Effect Of Two Different Maxillary Treatment Options On Supporting Structures Of Mini Implant Retained Mandibular Overdenture, Fardos N. Rizk Jul 2016

Effect Of Two Different Maxillary Treatment Options On Supporting Structures Of Mini Implant Retained Mandibular Overdenture, Fardos N. Rizk

Dentistry

Objectives: This study was conducted to evaluate whether maxillary conventional complete denture or narrow diameter implant retained maxillary overdenture is more compatible on opposing crestal bone height surrounding mini implants retaining mandibular overdenture. Materials and Methods: Fourteen male completely edentulous patients received mandibular overdentures retained by four one piece mini implants with ERA attachments placed anterior to the mental foramen. Patients were randomly divided into two groups: Group I received opposing maxillary conventional complete denture and Group II received opposing maxillary overdenture retained by four one piece narrow diameter implants with ball attachments placed in the anterior maxilla. Once patients …


Comparative Study Of Retention Of Palate-Less Versus Complete Palatal Coverage Dentures Fitted With Zirconia Mucosal Inserts, Fardos N. Rizk Oct 2015

Comparative Study Of Retention Of Palate-Less Versus Complete Palatal Coverage Dentures Fitted With Zirconia Mucosal Inserts, Fardos N. Rizk

Dentistry

Objective: The purpose of this study is to compare the retention of palate-less versus complete palatal coverage dentures fitted with zirconia mucosal inserts. Materials and Methods: Fourteen male patients received upper complete dentures fitted with zirconia mucosal inserts. Half of the dentures were fabricated with complete palatal coverage (Group I) and the other half was palate-less (Group II).Retention was measured for all patients using force measurement gauge through six months follow-up period. Results: Both groups showed increase in denture retention through the follow-up period however, dentures with complete palatal coverage (Group 1) showed higher mean values of retention compared to …


Comparative Study Of Implant Stability And Bone Height Changes Among Different Implant Designs Retaining Partial Overdenture, Fardos N. Rizk Jul 2015

Comparative Study Of Implant Stability And Bone Height Changes Among Different Implant Designs Retaining Partial Overdenture, Fardos N. Rizk

Dentistry

Objective: This study was conducted to assess the primary stability of Trabecular Metal Dental Implant and Tapered Screw Vent Implant to determine the appropriate time for their loading by lower partial overdenture and to follow up for one year the changes in implant stability and crestal bone height surrounding the implant after loading it. Materials and Methods: The study was performed on ten lower Kennedy class I partially edentulous male patients. Each patient received one implant at the second molar area in each side of the ridge, where Trabecular Metal Dental Implant was inserted in the left side of the …


Radiographic Evaluation Of Accuracy Of Surgical Stent For Implant Placement In Knife Edge Posterior Mandibular Ridge In Cases Of Ridge Splitting, Fardos N. Rizk, Engy Abdelhamed Jul 2014

Radiographic Evaluation Of Accuracy Of Surgical Stent For Implant Placement In Knife Edge Posterior Mandibular Ridge In Cases Of Ridge Splitting, Fardos N. Rizk, Engy Abdelhamed

Dentistry

Aim: This study was conducted to evaluate the efficacy of using conventional surgical stents guided by cone beam computed tomography in determining the position and buccolingual inclination of implants placed in posterior mandibular knife edge ridge in cases of ridge splitting with and without bone grafting material. Materials and Methods: The study was conducted on sixteen implants placed bilaterally in posterior knife edge mandibular ridge of four patients, where each patient received four implants in the form of two in each side. Implants on the right side of the ridge were placed following ridge splitting and bone grafting (group A). …


Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture, Fardos N. Rizk Apr 2014

Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture, Fardos N. Rizk

Dentistry

Aim: This study was conducted to compare the effect of ball and socket attachment and GPS attachment in implant retained mandibular overdenture cases regarding changes in: crestal bone height and density surrounding implants, electromyographic activity of temporalis and masseter muscles and occlusal biting force. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdenture. Four months following the surgery patients were randomly divided into two equal groups; Group-I received ball and socket attachment while Group-II received GPS attachment upon which mandibular overdentures were …


Comparative Evaluation Of Two Different Castable Bar Attachments In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk Jul 2013

Comparative Evaluation Of Two Different Castable Bar Attachments In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk

Dentistry

Objective: This research was carried to evaluate which solitary attachment; OT Cap Ball attachment or OT Cap Equator Profile attachment mounted on a bar splinting two implants retaining mandibular overdenture is more favorable regarding crestal bone height and bone density changes surrounding the implants using cone beam computed tomography. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdenture. Four months following the surgery patients were randomly divided into two equal groups; Group-I received two OT Cap Ball attachments mounted on a bar …


Radiographic Evaluation Of Marginal Bone Levels Around Platform-Switched Implants And Non-Platform-Switched Implants Immediately Loaded To Support Mandibular Overdenture, Fardos N. Rizk, Eatmad Elrekaby Apr 2013

Radiographic Evaluation Of Marginal Bone Levels Around Platform-Switched Implants And Non-Platform-Switched Implants Immediately Loaded To Support Mandibular Overdenture, Fardos N. Rizk, Eatmad Elrekaby

Dentistry

Objective: This clinical study was conducted to assess the marginal bone level around two different types of implant abutment junctions which are the platform-switched connection and non-platform- switched connection used in cases of implants supporting mandibular overdentures following the immediate loading protocol. Materials and Methods: Twelve completely edentulous male patients were randomly divided into two equal groups: Group I: Each patient received two Legacy I Implants designed with internal bevel having 3.5mm implant platform diameter to which 3.5mm neck diameter healing collars were threaded creating a matching or non-platform switching mechanism at the implant abutment junction. Group II: Each patient …


Premaxillary Characteristics In Complete Bilateral Cleft Lip And Palate: A Predictor For Treatment Outcome, Noha Ibrahim Abdelrahman Professor, Islam Tarek Hassan Professor Jan 2013

Premaxillary Characteristics In Complete Bilateral Cleft Lip And Palate: A Predictor For Treatment Outcome, Noha Ibrahim Abdelrahman Professor, Islam Tarek Hassan Professor

Dentistry

Objectives:

The aim of the current study was to investigate how bilateral cleft lip and palate (BCLP) cases responded differently to presurgical orthopedics (PSO) and primary lip repair (LR) based on premaxillary characteristics. We suggest a clinically oriented descriptive classification for BCLP based on premaxillary characteristics.

Design and Setting:

A retrospective longitudinal comparative study where available records of all non-syndromic patients with complete BCLP attending the Cleft Clinic, affiliated to the Oral and Maxillofacial Surgery department, Ain-Shams University, Cairo, Egypt were assessed.

Sample Population and Methodology:

Twenty-two cases were collected over a 4-years period from 2008 to 2011 (15 boys …


Effect Of Two Different Implant Structures On Stresses Induced Within The Surrounding Bone Using Three Dimensional Finite Element Analysis, Fardos N. Rizk Apr 2012

Effect Of Two Different Implant Structures On Stresses Induced Within The Surrounding Bone Using Three Dimensional Finite Element Analysis, Fardos N. Rizk

Dentistry

objective: The purpose of this study is to compare the stresses induced within the bone surrounding the Trabecular Metal Dental Implant (Zimmer Dental Inc., Carlsbad, CA, USA) in comparison to the stresses induced within the bone surrounding its predicate Tapered Screw Vent Implant (Zimmer Dental Inc., Carlsbad, CA, USA) using three dimensional finite element analysis. materials and methds: The current finite element analysis simulated a clinical situation where an edentulous mandible was restored with an entirely implant supported cantilever bar overdenture retained by five implants placed parallel to each other in the interforaminal region opposed by a complete denture. Two …


Comparative Study Of Ot Equator Profile Attachment Versus Gps Attachment In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk Jan 2012

Comparative Study Of Ot Equator Profile Attachment Versus Gps Attachment In Implant Retained Mandibular Overdenture Cases, Fardos N. Rizk

Dentistry

Aim: This study was carried out to evaluate whether OT Equator Profi le attachment or GPS attachment is less destructive to crestal bone around implants and to bone in distal aspect of the ridge in implant retained mandibular overdenture cases. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdentures. Four months following the surgery patients were randomly divided into two equal groups; Group-I received OT Equator Profi le attachment while Group-II received GPS attachment upon which mandibular overdentures were retained. Once patients …


Radiodensitometric Evaluation Of The Effect Of Low Energy Laser Irradiation With And Without Anioxidant Therapy On Immediately Loaded Implant Supported Overdenture, Fardos N. Rizk, Mouchira Salah Eldin Prof. Oct 2011

Radiodensitometric Evaluation Of The Effect Of Low Energy Laser Irradiation With And Without Anioxidant Therapy On Immediately Loaded Implant Supported Overdenture, Fardos N. Rizk, Mouchira Salah Eldin Prof.

Dentistry

objective: The purpose of this study is to compare the bone height and density around immediately loaded implants placed in the canine area supporting a mandibular overdenture in four different groups. The first group received low level laser therapy and antioxidants. The second group received antioxidants only. The third group received low level laser therapy only. The fourth group (control group) received no therapy. materials and methods: Following one stage surgical protocol twenty four implants were inserted bilaterally in the canine region to support mandibular overdentures for twelve completely edentulous patients in the form of two implants per patient. Patients …


Hyperbaric Oxygen Therapy For Promoting Osseointegration Around Dental Implants In Heavy Smokers, Fardos N. Rizk, Nasser Shaheen Jul 2011

Hyperbaric Oxygen Therapy For Promoting Osseointegration Around Dental Implants In Heavy Smokers, Fardos N. Rizk, Nasser Shaheen

Dentistry

Objective: The purpose of this study is to evaluate the effect of hyperbaric oxygen (HBO) therapy on osseointegration of implants supporting mandibular overdenture in heavy smokers. Materials and Methods: Following two stage surgical protocol twelve completely edentulous male heavy smokers received implants placed bilaterally in the canine region to support mandibular overdenture. On the second day after the surgery patients were divided randomly into two equal groups. Patients of group I were placed on a protocol of five consecutive sessions of HBO therapy, while patients of group II received no therapy and served as control. Four months following the surgery …