Open Access. Powered by Scholars. Published by Universities.®

Orthodontics and Orthodontology Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 13 of 13

Full-Text Articles in Orthodontics and Orthodontology

Comparison Of Immediate Vs. Delayed Recall Of Orthodontic Information Following An Electronic Reminder, Michael Lenz Jul 2018

Comparison Of Immediate Vs. Delayed Recall Of Orthodontic Information Following An Electronic Reminder, Michael Lenz

Master's Theses (2009 -)

Patients and parents in dentistry often do not remember important information disclosed during the informed consent process, so improvement in the delivery of information is needed. This study explored the effect of an emailed narrated instructional PowerPoint on the immediate vs. delayed recall and comprehension of informed consent information in orthodontics. Thirty-two subjects were recruited from a university and private practice orthodontic clinic. At the initial visit, subjects were alternately assigned to one of two groups and were presented with a mock orthodontic treatment plan and informed consent presentation for a pretend patient. Immediately following the presentation, the subjects’ verbal …


Direct Visual Approximation Of Arch Length Discrepancy And Cephalometric Measurements, Bradley J. Wurm Jul 2017

Direct Visual Approximation Of Arch Length Discrepancy And Cephalometric Measurements, Bradley J. Wurm

Master's Theses (2009 -)

Introduction: Arch length discrepancy and cephalometric analysis are critical components of orthodontic treatment planning. Both have direct effects on the decision to extract teeth or not and treatment mechanics as well. Visual approximation is the most common method used to analyze arch length discrepancy among practitioners. Current trends show a decrease in the amount of orthodontists completing a cephalometric analysis. Previous studies have shown a tendency for orthodontists to overestimate the degree of crowding when visually approximating on dental casts. No previous study has assessed the ability to visually approximate cephalometric angle measurements. The purpose of this survey was to …


Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen Jul 2016

Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen

Master's Theses (2009 -)

Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clinical advantages such as a lower stress hysteresis. Many orthodontic companies claim that their copper-nickel-titanium manufacturing process allows for the production of more consistent transition temperatures in the wires, allowing the orthodontist to customize treatment to various patients based on the force level needed. There are currently many manufacturers of these wires, creating a wide range of copper-nickel-titanium archwires from which …


Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert Jul 2016

Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert

Master's Theses (2009 -)

Introduction: Copper Nickel-Titanium (CuNiTi) is a relatively new composition of Nickel-Titanium (NiTi) archwires that was originally patented in 1991 as part of the Ormco line of wires. The patent has now recently expired and many other orthodontic companies are making their own CuNiTi wires. Advertisement claims have focused on the laboratory benefits of adding Copper (Cu) to the NiTi, however few independent laboratory testings have been conducted on these new wires to verify claims. The purpose of this study was to conduct thermal analysis of CuNiTi for all currently available wires in two Austenite Finish (Af) variants and two commonly …


The Effect Of Orthodontic Appliances On The Evaluation Of The Professionalism And Esthetics Of An Adult Employee, Laura Hanson Vaccariello Jul 2016

The Effect Of Orthodontic Appliances On The Evaluation Of The Professionalism And Esthetics Of An Adult Employee, Laura Hanson Vaccariello

Master's Theses (2009 -)

This study explored the influence of fixed and removable orthodontic appliances on participants’ ratings of the job performance, intelligence, and attractiveness of an adult female. Ninety-four adult subjects were recruited from the Graduate School of Management at Marquette University. Each subject received an identical employee performance review with an attached photograph of a female employee. The smile of the photo was manipulated to represent one of four conditions: no orthodontic appliance, a metal orthodontic appliance, a ceramic orthodontic appliance, or a clear aligner. Subjects then rated the employee on three continuous Likert scales. Ratings of job performance, intelligence, and attractiveness …


Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff Jul 2015

Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff

Master's Theses (2009 -)

Objective: The objective of this study was to determine the influence of fluoride and stress on the mechanical properties of nickel-titanium open coil springs. Materials and Methods: Sentalloy nickel-titanium open coil springs (15 mm length) were divided into five groups. A control group was tested mechanically in as-received condition. The other four experimental groups were exposed to artificial saliva (Fusayama-Meyer solution) at 37oC for 12 weeks in a 2x2 factorial design with fluoride exposure and stress (compression) as the two factors. Those springs which were under compression were held at 5 mm in length for the entirety of the testing …


The Direct Effect Of Low-Magnitude High-Frequency Mechanical Vibration On Osteoclast Formation From Raw267.4 Monocytes, Maxwell Antonio Abraham Jul 2015

The Direct Effect Of Low-Magnitude High-Frequency Mechanical Vibration On Osteoclast Formation From Raw267.4 Monocytes, Maxwell Antonio Abraham

Master's Theses (2009 -)

Low-magnitude high-frequency (LMHF) mechanical vibration has been demonstrated to enhance bone formation possibly through inhibition of osteoclastogenesis of bone. Earlier research has demonstrated osteoclast formation from RAW264.7 monocytes was inhibited by a chewing cycle mimicking vibration through inhibition of dendritic cell-specific transmembrane protein (DC-STAMP). We hypothesize that application of LMHF mechanical vibration directly inhibits osteoclast formation from RAW264.7 monocytes in a frequency dependent manner. RAW264.7 monocytes (ATCC) were cultured in alpha minimal essential medium (MEM) with 10% fetal bovine serum (FBS ) and 1% Pen/Strep at 37°C and 5% CO2. The cells were seeded at a density of 2000 cells/well …


Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes Jul 2015

Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes

Master's Theses (2009 -)

The aim of this study was to examine the effects of fluoride and stress on the electrochemical properties of nickel-titanium coils. Forty Dentsply GAC NiTi coils were divided into four groups of ten and individually tested. Twenty coils were placed in a solution of artificial saliva, where ten of the twenty were compressed and the other ten were not stressed. The other twenty coils were placed in a 1500 ppm NaF solution, where ten were compressed and ten were not. The coils were connected to a computer driven potentiostat and three tests were conducted: open circuit potential monitoring for 2 …


Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske Jul 2015

Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske

Master's Theses (2009 -)

Background/Objectives: This study aimed to investigate the viscoelastic properties of two clear aligner systems, Invisalign (Align Technology, Inc, Santa Clara, CA, USA) and Simpli5 (Allesee Orthodontic Appliances, Sturtevant, WI, USA), and determine if there was a difference after use. A survey assessed patients’ perceptions of the aligner material and post-treatment satisfaction. Materials/Methods: Mandibular aligners were collected from two patients after 2-3 weeks of use (n=6). Duplicate, unused aligners were obtained for each patient (n=6). Dynamic mechanical analysis (DMA) characterized the viscoelastic properties of the materials. Three tests were done on separate specimens: frequency scan (0.1-10 Hz under 25 μm displacement …


Microstructure And Mechanical Properties Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amanda Olejniczak Jul 2014

Microstructure And Mechanical Properties Of Nickel-Free And Nickel-Containing Stainless Steel Orthodontic Wires, Amanda Olejniczak

Master's Theses (2009 -)

Introduction: In orthodontics, contact dermatitis caused by nickel allergy should be of concern with the number of nickel-containing appliances and wires used. Stainless steel archwires are commonly used throughout orthodontic treatment. With the release of nickel from these wires, some manufacturers have turned to nickel-free stainless steel alternatives. The goal of this research was to compare nickel-free stainless steel with traditional stainless steel archwires with regard to mechanical properties and microstructure. Materials and Methods: Nickel-free stainless steel and regular stainless steel archwires from four companies were included. Five random samples of each wire, vertically mounted in fast-set acrylic, were indented …


Dimensional Changes Of Facial Soft Tissue Associated With Rapid Palatal Expansion, Peter Charles Longo Jul 2014

Dimensional Changes Of Facial Soft Tissue Associated With Rapid Palatal Expansion, Peter Charles Longo

Master's Theses (2009 -)

Introduction: Orthodontic treatment demands excellent outcomes in both function and esthetics. Despite the popularity of rapid palatal expansion in orthodontic treatment, few studies have examined its consequences on facial soft tissue using direct anthropometric measurements. The primary goal of this study was to determine facial soft tissue changes immediately following rapid palatal expansion. Materials and Methods: Twenty-eight patients (age range, 8-17 years) attending Marquette Dental School Orthodontic Post-Graduate Clinic were enrolled in the study. Facial soft tissue measurements were taken with digital calipers at two separate time points (T0: initial exam and T1: thirty days following expansion); measurements were recorded …


An Investigation Into The Bonding Properties Of New Generation Ceramic Brackets As Compared To A Stainless Steel Bracket, Ami Inoue Jul 2014

An Investigation Into The Bonding Properties Of New Generation Ceramic Brackets As Compared To A Stainless Steel Bracket, Ami Inoue

Master's Theses (2009 -)

Introduction: More patients are seeking esthetic alternatives for their orthodontic treatment options, which has led to increased use of ceramic brackets in recent years. These brackets were marketed before independent scientific research was completed. Many of the early ceramic brackets used a silane coupling agent to allow for a chemical bond between the bracket and the adhesive resin. Early reports from clinicians of increased bond strengths and iatrogenic tooth damage after bracket removal were common. Manufacturers have made changes to their base designs, relying more on mechanical retention for bond strength. The goal of this study was to test the …


Friction Testing Of A New Ligature, Alison Mantel Apr 2011

Friction Testing Of A New Ligature, Alison Mantel

Master's Theses (2009 -)

Objective: To determine if American Orthodontics' (AO) new, experimental ligature demonstrates less friction in vitro when compared to four other ligatures on the market.

Methods: Four brackets were mounted on a custom metal fixture allowing an 0.018-in stainless steel wire attached to an opposite fixture with one bracket to be passively centered in the bracket slot. The wire was ligated to the bracket using one of five types of ligatures including the low friction test ligatures (AO), conventional ligatures (AO), Sili–TiesTM, Silicone Infused Ties (GAC), Synergy® Low-Friction Ligatures (RMO), and SuperSlick ligatures (TP Orthodontics). Resistance to sliding was measured over …