Open Access. Powered by Scholars. Published by Universities.®
Oral and Maxillofacial Radiology Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- CBCT (2)
- 3D printing (1)
- Anomalies (1)
- Arthrocentesis; Hyaluronic acid; Single needle double-barrel cannula; Ultrasound (1)
- Artificial intelligence; periapical radiography; periapical periodontitis; diagnosis; deep learning; diagnostic accuracy; ChatGPT (1)
-
- Bilateral sagittal split osteotomy (BSSO) (1)
- Computer-guided surgery (1)
- Condylar positioning device (CPD) (1)
- Cone-beam computed tomography (CBCT) (1)
- Curved canals (1)
- Developmental (1)
- E3 Azure (1)
- Incisive canal (1)
- Interpretation (1)
- Low-dose CBCT High-dose CBCT Furcation involvement Periodontal diagnosis Diagnostic accuracy Radiation dose reduction (1)
- Nasopalatine Canal (1)
- Occlusal splint (1)
- Orthognathic surgery (1)
- T-Blue (1)
- Temporomandibular joint (TMJ) (1)
- Three-dimensional detailed information (1)
- Virtual surgical planning (1)
- Waferless surgery (1)
- XPS (1)
Articles 1 - 7 of 7
Full-Text Articles in Oral and Maxillofacial Radiology
Dens Invaginatus Prevalence In Maxillary Lateral Incisors In Egyptian Population: Cone Beam Computed Tomography 3-Dimensional Analysis, Marwa Ezz, Sherif Heidar, Mahinaz Reda Abdelhamed
Dens Invaginatus Prevalence In Maxillary Lateral Incisors In Egyptian Population: Cone Beam Computed Tomography 3-Dimensional Analysis, Marwa Ezz, Sherif Heidar, Mahinaz Reda Abdelhamed
Dentistry
Introduction: Dens invaginatus also called dens in dente is frequent developmental anomaly, most commonly affect maxillary lateral incisors. It can create an inflammatory and microbial pathway that may compromise pulp vitality. Once detected, intervention must be planned. Aim of the study : This study investigated Dens invaginatus prevalence in maxillary lateral incisors in Egyptian population and its categorization according to Oehlers classification using CBCT. Materials and Methods This study assessed 296 cone beam computed tomography scans including a total number of 592 maxillary lateral incisor. Two experienced examiners: an oral and maxillofacial radiologist and an endodontist, inspected Dens invaginatus in …
Artificial Intelligence Versus Human Dental Expertise In Diagnosing Periapical Pathosis On Periapical Radiographs: A Multicenter Study, Fatma E.A Hassanen, Radwa R. Hussein, Mohamed Riad Elgarhy, Shaymaa Mohamed Maher, Marwa Ezz, Ahmed Hassen, Sherif Heidar, Amr Edress, Asmaa Abou-Bakr
Artificial Intelligence Versus Human Dental Expertise In Diagnosing Periapical Pathosis On Periapical Radiographs: A Multicenter Study, Fatma E.A Hassanen, Radwa R. Hussein, Mohamed Riad Elgarhy, Shaymaa Mohamed Maher, Marwa Ezz, Ahmed Hassen, Sherif Heidar, Amr Edress, Asmaa Abou-Bakr
Dentistry
Periapical pathosis in periapical radiographs must be properly diagnosed for the success of endodontic treatment but is often muddled by 2D imaging limitations and subjective interpretation. Artificial intelligence (AI) offers a solution, but whether the diagnostic granularity of AI versus human clinicians in everyday clinical practice has been adequately explored remains to be addressed. The purpose of this study was to evaluate the diagnostic accuracy of ChatGPT-5 in detecting periapical radiographic abnormalities compared with the three-expert consensus reference standard. Methods: In this diagnostic accuracy retrospective study, 270 periapical radiographs were independently read by a large language model (ChatGPT-5) and a …
Low Dose Cone Beam Computed Tomography Versus High Dose Cone Beam Computed Tomography In Measuring Furcation Involvements: (Diagnostic Accuracy Study), Marwa Ezz, Cairo University, Misr University For Science & Technology
Low Dose Cone Beam Computed Tomography Versus High Dose Cone Beam Computed Tomography In Measuring Furcation Involvements: (Diagnostic Accuracy Study), Marwa Ezz, Cairo University, Misr University For Science & Technology
Dentistry
Accurate diagnosis of furcation defect is essential in periodontal therapy planning. Cone beam computed tomography (CBCT) provides three-dimensional visualization, but higher radiation doses remain a concern. This study aims to assess and compare the diagnostic accuracy of low-dose CBCT (LD-CBCT) and high-dose CBCT (HD-CBCT) in detecting and measuring furcation defect using a pig mandible. Detection and accurate assessment of periodontal disease is important to determine the tooth prognosis and treatment. Radiographic assessment provides information about the pattern and extent of the furcation defect. CBCT provides unique 3D images used for diagnosis and treatment plans, but its use in periodontology not …
Does Ultrasound Guidance During Arthrocentesis In Women With Disc Displacement Without Reduction Reduce Procedure Time And Improve Outcomes? A Randomized Clinical Trial, Moataz Dr. Bahaa, Abdelrahman Fahmy Dr., Hisham Elsheikh Dr., Bassam Abulnoor, Amr Amin Prof., Sherif El Bahnasy, Karim Abdelmohsen Prof
Does Ultrasound Guidance During Arthrocentesis In Women With Disc Displacement Without Reduction Reduce Procedure Time And Improve Outcomes? A Randomized Clinical Trial, Moataz Dr. Bahaa, Abdelrahman Fahmy Dr., Hisham Elsheikh Dr., Bassam Abulnoor, Amr Amin Prof., Sherif El Bahnasy, Karim Abdelmohsen Prof
Dentistry
Introduction: The goal of using ultrasound-guided (USG) arthrocentesis is to reduce number of needle insertion attempts, which is hypothesized to reduce procedure time, postoperative pain, and consequently, limitation in range of motion. Purpose: The objective of this study was to compare the therapeutic and operative efficiency of USG Single-Puncture Arthrocentesis (SPA) Type 2 and SPA Type 2 arthrocentesis without ultrasound guidance in the treatment of temporomandibular joint (TMJ) internal derangement (ID) “disc displacement without reduction (DDWOR).” Materials and methods: A double-blinded prospective randomized clinical trial (RCT) was conducted from December 2022 to December 2023 at Ain Shams University Hospital. It …
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Sherif Shafik
Centering And Shaping Abilities Of Three Different Cross-Section Rotary Systems In Curved Canals Using Cbct, Sherif Shafik
Dentistry
ABSTRACT The aim of the study was to examine the centering and shaping abilities of the E3 Azure, T Blue and XPRS rotary devices in severely curved root canals utilizing CBCT. 51 mesial roots were used in this study, then distributed into three groups of 17 mesial canals each according to the instrumentation technique: T-Blue, E3 Azure and XPS. The final apical size of instrumentation was 30/0.04 for all groups. At 2 mm, all pairwise comparisons were statistically significant, with Azure showing the highest transportation, followed by T-Blue, and XPS showing the least (p< 0.001). At 4 mm and 6 mm, Azure and T-Blue showed significantly higher transportation than XPS (p< 0.001). For XP-Shaper files, centering ratios followed a descending order from 6 mm to 4 mm and were lowest at 2 mm, with all pairwise comparisons being statistically significant (p< 0.001). it was concluded that XPS show lesser transportation and better centering ability.
Digitally Fabricated Interocclusal Wafer Versus Wafer-Less Distal Segment Repositioning For Bilateral Sagittal Split Osteotomy (Bsso) In Skeletal Mandibular Deformities (Randomized Controlled Trial), Hesham Osama Morsi Ass.Lect., Mohammed Abdelsalam Omara Ass.Prof., Mostafa Ibrahim Shindy Prof, Galal Gamal El Behairy Prof.
Digitally Fabricated Interocclusal Wafer Versus Wafer-Less Distal Segment Repositioning For Bilateral Sagittal Split Osteotomy (Bsso) In Skeletal Mandibular Deformities (Randomized Controlled Trial), Hesham Osama Morsi Ass.Lect., Mohammed Abdelsalam Omara Ass.Prof., Mostafa Ibrahim Shindy Prof, Galal Gamal El Behairy Prof.
Dentistry
Objective: This study aimed to compare the accuracy of condylar positioning between 2 computer-guided orthognathic surgical protocols: a waferless screw hole plate locating (WSL CPD) technique versus an occlusal splint with distal extending arms (OWDA-CPD) approach. Materials and Methods: Twenty-four patients requiring mandibular orthognathic surgery (class II or III deformities) were randomly allocated into 2 groups (n=12 each). Group I underwent a waferless protocol utilizing 3D-printed osteotomy and screw hole locating guides, while group II received an occlusal splint with distal extensions for condylar positioning. Preoperative and postoperative cone-beam computed tomography (CBCT) scans were used to assess condylar displacement in …
Assessment Of Incisive Canal Morphology And Position In A Sample Of Egyptian Population: A Cone Beam Computed Tomography Study, Sherif Shafik
Assessment Of Incisive Canal Morphology And Position In A Sample Of Egyptian Population: A Cone Beam Computed Tomography Study, Sherif Shafik
Dentistry
ABSTRACT Several studies have highlighted the diversity in the anatomy of the incisive canal. Evaluation of incisive canal as well as its approximation to the maxillary incisor root is crucial before orthodontic treatment, implant placement and other surgical procedures in the anterior maxillary area. Cone beam computed tomography (CBCT) provides detailed three-dimensional information and have been used to evaluate the nasopalatine region with high accuracy along with relative safety due to low radiation exposure. Aim: The study aimed to provide analysis of the nasopalatine canal anatomy using cone-beam computed tomography (CBCT) in a sample of the Egyptian population. Materials & …