Open Access. Powered by Scholars. Published by Universities.®

Cardiovascular System Commons™

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 1 - 30 of 39

Full-Text Articles in Cardiovascular System

Robust Non-Invasive Cardiac Index Prediction Via Feature Integration And Data-Augmented Neural Networks, Chih-Hao Chang, Mei-Ling Chan, Yu-Hung Fang, Po-Lin Huang, Tsung-Yi Chen, Tsun-Kuang Chi, I Elizabeth Cha, Tzong-Rong Ger, Kuo-Chen Li, Shih-Lun Chen, Liang-Hung Wang, Jia-Ching Wang, Patricia Angela R. Abu Apr 2026

Robust Non-Invasive Cardiac Index Prediction Via Feature Integration And Data-Augmented Neural Networks, Chih-Hao Chang, Mei-Ling Chan, Yu-Hung Fang, Po-Lin Huang, Tsung-Yi Chen, Tsun-Kuang Chi, I Elizabeth Cha, Tzong-Rong Ger, Kuo-Chen Li, Shih-Lun Chen, Liang-Hung Wang, Jia-Ching Wang, Patricia Angela R. Abu

Department of Information Systems & Computer Science Faculty Publications

Concurrent with the rising consumption of ultra-processed, high-calorie diets and the decline in physical activity, obesity and related cardiovascular conditions among young adults have continued to increase, becoming an important global public health concern. This study integrates non-invasive Internet of Things (IoT) sensing devices, including the TERUMO ES-P2000 blood pressure monitor (Terumo Corp., Tokyo, Japan) and the PhysioFlow PF07 Enduro cardiac hemodynamic analyzer (Manatec Biomedical, Poissy, France), with an artificial neural network (ANN) for cardiac index (CI) prediction. Through appropriate data preprocessing and model training strategies, the generalization ability and stability of the proposed CI prediction model were significantly enhanced. …


Mechanical Characterization And Modeling Of Rat Myocardia Under The Influence Of Epirubicin, Abdallah Mahmoud Alkhaiyat Jan 2026

Mechanical Characterization And Modeling Of Rat Myocardia Under The Influence Of Epirubicin, Abdallah Mahmoud Alkhaiyat

Theses and Dissertations

Cancer remains a predominant health challenge that is responsible for a significant portion of global morbidity and mortality. Epirubicin (EPI), a chemotherapeutic anti-cancer drug, has shown remarkable efficacy in combating various malignancies. However, it is known to have undesirable side effects on the heart, collectively referred to as cardiotoxicity. This research investigates the adverse effects of chemotherapy on cardiac contractility through an in vitro examination of the mechanics of healthy and infarcted animal heart tissues. Electrically stimulated slices of rat ventricular tissue were tested using an isometric force measurement tissue bath. The tissue slices were subjected to uniaxial stretching, allowing …


Influence Of Motion Artifacts On Instantaneous Frequency Based Heart Rate Variability Of Arterial Pulse Signals Measured By A Tactile Sensor: An Analytical Study, Mamun Hasan, Zhili Hao Jan 2026

Influence Of Motion Artifacts On Instantaneous Frequency Based Heart Rate Variability Of Arterial Pulse Signals Measured By A Tactile Sensor: An Analytical Study, Mamun Hasan, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

Objective: Heart rate variability (HRV), quantified via the instantaneous frequency (IF) of arterial pulse signals, is a key indicator of cardiovascular (CV) regulation. This study presents a theoretical and experimental investigation of how motion artifacts (MA) influence IF-and thus HRVmeasured with a tactile sensor, emphasizing underlying mechanisms rather than population-level validation. Approach: Building on a previously developed single-degree-of-freedom (SDOF) model of the tissue-contact-sensor (TCS) stack between the sensor and the artery, MA is represented as low-frequency baseline drift and time-varying system parameters (TVSP) of the TCS stack. Analytical expressions quantify the effect of MA on the IF of each harmonic …


Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao Jan 2026

Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …


Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao Jan 2026

Radial And Carotid Arterial Pulse Signals For Assessing Cardiovascular Function At Rest And During Post-Exercise Recovery In A Heart Transplant Patient: A Case Study, Md Mahfuzur Rahman, Mamun Hasan, Jennifer F. May, John M. Herre, Leryn Reynolds, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

Aim: This study investigates the feasibility of using radial and carotid arterial pulse signals to assess cardiovascular (CV) function at rest and during post-exercise recovery in a heart transplant (HTx) patient. Method: Two micro-fabricated tactile sensors were used to simultaneously acquire arterial pulse signals at the radial artery (RA) and carotid artery (CA). Measurements were taken at rest and at multiple time points post-exercise on three subjects: an HTx patient, a percutaneous coronary intervention (PCI; coronary stent) patient and a healthy control. An SDOF-TF-based time-frequency analysis algorithm was applied to extract a comprehensive set of CV parameters, including heart rate …


A Low-Cost Fourier-Based Dual-Pump Mock Circulatory Loop For Arterial Pressure Waveform Reproduction, Victor K. Tsui, Kouhyar Tavakolian, Daniel Ewert Jan 2026

A Low-Cost Fourier-Based Dual-Pump Mock Circulatory Loop For Arterial Pressure Waveform Reproduction, Victor K. Tsui, Kouhyar Tavakolian, Daniel Ewert

Electrical & Computer Engineering Faculty Publications

Cardiovascular diseases are among the leading causes of death worldwide, creating a need for reliable hemodynamic testing platforms for cardiovascular device evaluation and therapeutic development. Mock circulatory loops (MCLs) provide effective in vitro platforms for reproducing physiological and pathological pressure conditions; however, many existing systems remain limited in programmability, waveform fidelity, standardization, and affordability. This study presents a cost-effective dual-pump hybrid MCL (hMCL) that independently regulates baseline and pulsatile pressure components using Fourier-based harmonic synthesis. Reference arterial pressure waveforms were decomposed into harmonic components, and their amplitudes, frequencies, and phase shifts were converted into pulse-width-modulation signals for dual-pump actuation. Validation …


Development Of A 3d-Printed Hemodynamic Model To Characterize Doppler Signatures Of Obstructed Tapvr, Michael R. Turner, Maher R. Saadeh, Holly D. Bauser-Heaton, Vahid Serpooshan Jan 2026

Development Of A 3d-Printed Hemodynamic Model To Characterize Doppler Signatures Of Obstructed Tapvr, Michael R. Turner, Maher R. Saadeh, Holly D. Bauser-Heaton, Vahid Serpooshan

Summer Research Program Abstracts

No abstract provided.


Yk-4-250, A Synthetic Telmisartan-Tempol Conjugate: Crystal Structure Of A Stabilized Free Radical Containing An Angiotensin At₁ Receptor Inhibitor, Simon Friedrich, Yali Kong, Faik N. Musayev, Milton L. Brown, B. Frank Gupton Jan 2026

Yk-4-250, A Synthetic Telmisartan-Tempol Conjugate: Crystal Structure Of A Stabilized Free Radical Containing An Angiotensin At₁ Receptor Inhibitor, Simon Friedrich, Yali Kong, Faik N. Musayev, Milton L. Brown, B. Frank Gupton

Department of Biomedical and Translational Sciences Faculty Publications

We report the first crystal structure of the telmisartan-tempol conjugate 2,2,6,6-tetramethyl-1-(λ'-oxidaneyl)piperidin-4-yl 4'-[(1,7'-dimethyl-2'-propyl-1H,3'H-[2,5'-bibenzo[d]imidazol]-3'-yl)methyl]-[1,1'-biphenyl]-2-carboxylate free radical (YK-4-250, C₄₂H₄₆N₅O₃), a dual-function inhibitor designed to target both the angiotensin II type 1 receptor (AT₁R) and reactive oxygen species (ROS). Structural analysis reveals a unique crystal architecture in which the nitroxide radical is stabilized within a sterically protected environment while preserving the telmisartan pharmacophore essential for high-affinity receptor antagonism. YK-4-250 is a novel small-molecule conjugate of telmisartan and tempol that incorporates a catalytic stabilized nitroxide radical and was rationally designed to mitigate gastrointestinal acute radiation syndrome (GI-ARS).


Ambulatory Arterial Stiffness Index: Regression Method Comparison And Its Association With Pulse Pressure And Circadian Patterns, José R. Ayala-Hernández, Cristina López-Sánchez, Orlando M. Ayala, Camilo E. Palencia-Tejedor Jan 2025

Ambulatory Arterial Stiffness Index: Regression Method Comparison And Its Association With Pulse Pressure And Circadian Patterns, José R. Ayala-Hernández, Cristina López-Sánchez, Orlando M. Ayala, Camilo E. Palencia-Tejedor

Engineering Technology Faculty Publications

The Arterial Stiffness Index (AASI) is a calculation obtained through Ambulatory Blood Pressure Monitoring (ABPM), and is an indirect measure of the elastic properties of the arterial wall; but there is heterogeneity in its scope as a predictor of vascular wall health. A comparison is made between linear regression and exponential regression of the AASI, as well as an analysis of variance, according to circadian patterns and pulse pressure (PP) values. This work is an analytical observational study in 106 individuals, most of them women (63%) with a mean age of 53 ± 17.32 years. The coefficient of determination (r2) …


An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao Jan 2025

An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part I: Accelerometers And Ppg Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue-contact-sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a …


An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part Ii: Tactile Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao Jan 2025

An Analytical Model Of Motion Artifacts In A Measured Arterial Pulse Signal—Part Ii: Tactile Sensors, Md Mahfuzur Rahman, Subodh Toraskar, Mamun Hasan, Zhili Hao

Mechanical & Aerospace Engineering Faculty Publications

This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse …


Identification And Characterization Of Two Novel Kcnh2 Mutations Contributing To Long Qt Syndrome, Anthony Owusu-Mensah, Jacqueline Treat, Joyce Bernardi, Ryan Pfeiffer, Robert Goodrow, Bright Tsevi, Victoria Lam, Michel Audette, Jonathan M. Cordeiro, Makarand Deo Jan 2024

Identification And Characterization Of Two Novel Kcnh2 Mutations Contributing To Long Qt Syndrome, Anthony Owusu-Mensah, Jacqueline Treat, Joyce Bernardi, Ryan Pfeiffer, Robert Goodrow, Bright Tsevi, Victoria Lam, Michel Audette, Jonathan M. Cordeiro, Makarand Deo

Electrical & Computer Engineering Faculty Publications

We identified two different inherited mutations in KCNH2 gene, or human ether-a-go-go related gene (hERG), which are linked to Long QT Syndrome. The first mutation was in a 1-day-old infant, whereas the second was in a 14-year-old girl. The two KCNH2 mutations were transiently transfected into either human embryonic kidney (HEK) cells or human induced pluripotent stem-cell derived cardiomyocytes. We performed associated multiscale computer simulations to elucidate the arrhythmogenic potentials of the KCNH2 mutations. Genetic screening of the first and second index patients revealed a heterozygous missense mutation in KCNH2, resulting in an amino acid change (P632L) in the …


The Effects Of Demographics And Risk Factors On The Morphological Characteristics Of Human Femoropopliteal Arteries, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy Mar 2023

The Effects Of Demographics And Risk Factors On The Morphological Characteristics Of Human Femoropopliteal Arteries, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy

UNO Student Research and Creative Activity Fair

Background: Disease of the lower extremity arteries (Peripheral Arterial Disease, PAD) is associated with high morbidity and mortality. During disease development, the arteries adapt by changing their diameter, wall thickness, and residual deformations, but the effects of demographics and risk factors on this process are not clear.

Methods: Superficial femoral arteries from 736 subjects (505 male, 231 female, 12 to 99 years old, average age 51±17.8 years) and the associated demographic and risk factor variables were used to construct machine learning (ML) regression models that predicted morphological characteristics (diameter, wall thickness, and longitudinal opening angle resulting from the …


Pulsatility Is A Predictive Marker Of Improved Cardiac Function In Patients With Liquid Matrix-Treated Left Ventricular Assist Devices, Philemon Mikail, Rinku Skaria, Marvin Slepian, Janny Garcia, Richard Smith, Zain Khalpey Jul 2022

Pulsatility Is A Predictive Marker Of Improved Cardiac Function In Patients With Liquid Matrix-Treated Left Ventricular Assist Devices, Philemon Mikail, Rinku Skaria, Marvin Slepian, Janny Garcia, Richard Smith, Zain Khalpey

The VAD Journal

Objective: Left ventricular assist devices (LVADs) are utilized as a bridge to transplant or as destination therapy for patients with end-stage heart failure. Although cardiac offloading from these devices rarely leads to complete remodeling and functional recovery, the use of mesenchymal cells to modulate heart failure has been explored in recent years due to its intrinsic regenerative properties. Current methods of evaluating cardiac function have too much variability, difficulty of access, or require too frequent follow up to create universal weaning protocols. We hypothesized that the administration of amniotic allograft liquid matrix (LM) containing amnion-derived mesenchymal stem cells (aMSCs) in …


Alternative Fixation Of Venous Valves For Bioprosthetic Applications, Makenzie Kapales May 2022

Alternative Fixation Of Venous Valves For Bioprosthetic Applications, Makenzie Kapales

Biomedical Engineering Undergraduate Honors Theses

Venous valve failure allows for the retrograde, or backward, flow of blood into the lower extremities, which leads to Chronic Venous Insufficiency (CVI). CVI infringes upon quality of life through ulceration and can result in death due to Deep Vein Thrombosis (DVT), or blood clots, causing pulmonary embolism. A successful treatment of CVI restores valve function and prevents retrograde blood flow; however, current bioprosthetic venous valves exhibit low patency and high calcification. To improve upon bioprosthetic venous valves and CVI treatment, the University of Arkansas’s Cardiovascular Biomechanics Lab conducts studies with the purpose of comparing the properties and performance of …


Design And Development Of Software With A Graphical User Interface To Display And Convert Multiple Microscopic Histology Images, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy Mar 2022

Design And Development Of Software With A Graphical User Interface To Display And Convert Multiple Microscopic Histology Images, Sayed Ahmadreza Razian, Majid Jadidi, Alexey Kamenskiy

UNO Student Research and Creative Activity Fair

Histological images are widely used to assess the microscopic anatomy of biological tissues. Recent advancements in image analysis allow the identification of structural features on histological sections that can help advance medical device development, brain and cancer research, drug discovery, vascular mechanobiology, and many other fields. Histological slide scanners create images in SVS and TIFF formats that were designed to archive image blocks and high-resolution textual information. Because these formats were primarily intended for storage, they are often not compatible with conventional image analysis software and require conversion before they can be used in research. We have developed a user-friendly …


The Heat Shock Protein 90 Inhibitor, At13387, Protects The Alveolo-Capillary Barrier And Prevents Hci-Induced Chronic Lung Injury And Pulmonary Fibrosis, Ruben M.L. Colunga Biancatelli, Pavel Solopov, Christiana Dimitropoulou, Betsy Gregory, Tierney Day, John D. Catravas Jan 2022

The Heat Shock Protein 90 Inhibitor, At13387, Protects The Alveolo-Capillary Barrier And Prevents Hci-Induced Chronic Lung Injury And Pulmonary Fibrosis, Ruben M.L. Colunga Biancatelli, Pavel Solopov, Christiana Dimitropoulou, Betsy Gregory, Tierney Day, John D. Catravas

Bioelectrics Publications

Hydrochloric acid (HCl) exposure causes asthma-like conditions, reactive airways dysfunction syndrome, and pulmonary fibrosis. Heat Shock Protein 90 (HSP90) is a molecular chaperone that regulates multiple cellular processes. HSP90 inhibitors are undergoing clinical trials for cancer and are also being studied in various pre-clinical settings for their anti-inflammatory and anti-fibrotic effects. Here we investigated the ability of the heat shock protein 90 (HSP90) inhibitor AT13387 to prevent chronic lung injury induced by exposure to HCl in vivo and its protective role in the endothelial barrier in vitro. We instilled C57Bl/6J mice with 0.1N HCl (2 µL/g body weight, intratracheally) and …


The Paradox Of Pulmonary Vascular Resistance: Restoration Of Pulmonary Capillary Recruitment As A Sine Qua Non For True Therapeutic Success In Pulmonary Arterial Hypertension, David Langleben, Stylianos E. Orfanos, Benjamin D. Fox, Nathan Messas, Michele Giovinazzo, John D. Catravas Jan 2022

The Paradox Of Pulmonary Vascular Resistance: Restoration Of Pulmonary Capillary Recruitment As A Sine Qua Non For True Therapeutic Success In Pulmonary Arterial Hypertension, David Langleben, Stylianos E. Orfanos, Benjamin D. Fox, Nathan Messas, Michele Giovinazzo, John D. Catravas

Bioelectrics Publications

Exercise-induced increases in pulmonary blood flow normally increase pulmonary arterial pressure only minimally, largely due to a reserve of pulmonary capillaries that are available for recruitment to carry the flow. In pulmonary arterial hypertension, due to precapillary arteriolar obstruction, such recruitment is greatly reduced. In exercising pulmonary arterial hypertension patients, pulmonary arterial pressure remains high and may even increase further. Current pulmonary arterial hypertension therapies, acting principally as vasodilators, decrease calculated pulmonary vascular resistance by increasing pulmonary blood flow but have a minimal effect in lowering pulmonary arterial pressure and do not restore significant capillary recruitment. Novel pulmonary arterial hypertension …


Hypertrophic Cardiomyopathy Β-Cardiac Myosin Mutation (P710r) Leads To Hypercontractility By Disrupting Super Relaxed State, Alison Schroer Vander Roest, Chao Liu, Makenna M. Morck, Kristina Bezold Kooiker, Gwanghyun Jung, Dan Song, Aminah Dawood, Arnav Jhingran, Gaspard Pardon, Sara Ranjbarvaziri, Giovanni Fajardo, Mingming Zhao, Kenneth S. Campbell, Beth L. Pruitt, James A. Spudich, Kathleen M. Ruppel, Daniel Bernstein Jun 2021

Hypertrophic Cardiomyopathy Β-Cardiac Myosin Mutation (P710r) Leads To Hypercontractility By Disrupting Super Relaxed State, Alison Schroer Vander Roest, Chao Liu, Makenna M. Morck, Kristina Bezold Kooiker, Gwanghyun Jung, Dan Song, Aminah Dawood, Arnav Jhingran, Gaspard Pardon, Sara Ranjbarvaziri, Giovanni Fajardo, Mingming Zhao, Kenneth S. Campbell, Beth L. Pruitt, James A. Spudich, Kathleen M. Ruppel, Daniel Bernstein

Physiology Faculty Publications

Hypertrophic cardiomyopathy (HCM) is the most common inherited form of heart disease, associated with over 1,000 mutations, many in β-cardiac myosin (MYH7). Molecular studies of myosin with different HCM mutations have revealed a diversity of effects on ATPase and load-sensitive rate of detachment from actin. It has been difficult to predict how such diverse molecular effects combine to influence forces at the cellular level and further influence cellular phenotypes. This study focused on the P710R mutation that dramatically decreased in vitro motility velocity and actin-activated ATPase, in contrast to other MYH7 mutations. Optical trap measurements of single myosin molecules revealed …


Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins May 2021

Design And Control Of A Peristaltic Pump To Simulate Left Atrial Pressure In A Conductive Silicone Model, Jeremy Collins

Mechanical Engineering Undergraduate Honors Theses

According to the CDC, atrial fibrillation is responsible for more than 454,000 hospitalizations and approximately 158,000 deaths per year. A common treatment for atrial fibrillation is catheter ablation, a process in which a long flexible tube is guided through the femoral artery and to the source of arrhythmia in the heart, where it measures the electrical potential at various locations and converts problematic heart tissue to scar tissue via ablation. This paper details the design and control of a low-cost ($400) peristaltic pump system using repetitive control to replicate blood pressure in the left atrium in a conductive silicone model …


Three-Dimensional (3d) Reconstruction Of Computer Tomography Cardiac Images Using Visualization Toolkit (Vtk), Mohammad Zahid Zamaludin Jan 2021

Three-Dimensional (3d) Reconstruction Of Computer Tomography Cardiac Images Using Visualization Toolkit (Vtk), Mohammad Zahid Zamaludin

Student Works (2020-2029)

Cardiac study proves to be important to diagnose and treat cardiovascular disease that accounts for 20% of death in the world. Three-dimensional (3D) images of the heart are important to understand its real structure, functions and physical abnormalities occurring in the tissue. The objective of this paper is to reconstruct 3D images from 2D CT Scan slices of the cardiac region of interest using Visualisation Toolkit (VTK). The Visualization Toolkit (VTK) is non-propriety software with state-of-the-art tools for 3D rendering that is easily customizable programming. 3D images are reconstructed using surface rendering technique and volume rendering technique. Volume rendering shows …


Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks Jan 2020

Enhancement Of The Syncardia Total Artificial Heart For Pediatric Use, Margaret Clark, Madison Marks

Williams Honors College, Honors Research Projects

Pediatric patients with disorders and diseases of the heart have limited options with regards to implantable devices. Many of these implants are ventricular assist devices, which is not always suitable for a patient. Total artificial hearts (TAHs) have supported many adult patients until transplantation, and we believe that they could do the same for pediatric patients. SynCardia has the only Food and Drug Administration (FDA) approved TAH devices. Since SynCardia is the only company with FDA approved TAHs, we decided to modify the design of the SynCardia TAH for use in pediatric patients without compromising the function of the current …


Using Peripheral Venous Pressure Waveforms To Predict Key Hemodynamic Parameters, Ali Zohair A Alalawi May 2019

Using Peripheral Venous Pressure Waveforms To Predict Key Hemodynamic Parameters, Ali Zohair A Alalawi

Graduate Theses and Dissertations

Analysis of peripheral venous pressure (PVP) waveforms is a novel method of monitoring intravascular volume. Two cohorts were used to study the hemodynamics change of the body state and its influence on the PVP using (1) dehydration setting with infants suffering from pyloric stenosis and (2) hemorrhage setting during a craniosynostosis elective surgery. The goal of this research is to develop a minimally invasive method of analyzing the PVP waveforms and find correlations with volume loss.

Twenty-three pyloric stenosis patients PVP were acquired at five stages and were divided into euvolemic, normal fluid volume, and hypovolemic, significant fluid loss. Seven …


Artificial Gravity As A Countermeasure To The Cardiovascular Deconditioning Of Spaceflight: Gender Perspectives, Joyce M. Evans, Charles F. Knapp, Nandu Goswami Jul 2018

Artificial Gravity As A Countermeasure To The Cardiovascular Deconditioning Of Spaceflight: Gender Perspectives, Joyce M. Evans, Charles F. Knapp, Nandu Goswami

Biomedical Engineering Faculty Publications

Space flight-induced physiological deconditioning resulting from decreased gravitational input, decreased plasma volume, and disruption of regulatory mechanisms is a significant problem in returning astronauts as well as in normal aging. Here we review effects of a promising countermeasure on cardiovascular systems of healthy men and women undergoing Earth-based models of space-flight. This countermeasure is produced by a centrifuge and called artificial gravity (AG). Numerous studies have determined that AG improves orthostatic tolerance (as assessed by various protocols) of healthy ambulatory men, of men deconditioned by bed rest or by immersion (both wet and dry) and, in one case, following spaceflight. …


In-Vitro Simulation Of Acute Ischemic Stroke, Paolo Garcia May 2018

In-Vitro Simulation Of Acute Ischemic Stroke, Paolo Garcia

Biomedical Engineering Undergraduate Honors Theses

Acute ischemic stroke (AIS) is a condition that involves the occlusion of a blood vessel within the brain, effectively preventing the passage of oxygen and nutrients. AIS is highly prevalent in the United States, where nearly 795,000 strokes happen per year and 87% of those are ischemic. From a medical standpoint, the obstructing clot can be removed with the use of a stroke retrieval device. However, a need arises for testing the aforementioned devices on a patient’s specific vascular geometries in order to increase the likelihood of a successful procedure. Outlined is a process for developing a physical simulation of …


Association Between Left Ventricular Mechanics And Diffuse Myocardial Fibrosis In Patients With Repaired Tetralogy Of Fallot: A Cross-Sectional Study, Christopher M. Haggerty, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, Gregory J. Wehner, Linyuan Jing, Richard J. Charnigo, Brandon K. Fornwalt, Mark A. Fogel Dec 2017

Association Between Left Ventricular Mechanics And Diffuse Myocardial Fibrosis In Patients With Repaired Tetralogy Of Fallot: A Cross-Sectional Study, Christopher M. Haggerty, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, Gregory J. Wehner, Linyuan Jing, Richard J. Charnigo, Brandon K. Fornwalt, Mark A. Fogel

Biomedical Engineering Faculty Publications

Background: Patients with repaired tetralogy of Fallot (TOF) have progressive, adverse biventricular remodeling, leading to abnormal contractile mechanics. Defining the mechanisms underlying this dysfunction, such as diffuse myocardial fibrosis, may provide insights into poor long-term outcomes. We hypothesized that left ventricular (LV) diffuse fibrosis is related to impaired LV mechanics.

Methods: Patients with TOF were evaluated with cardiac magnetic resonance in which modified Look-Locker (MOLLI) T1-mapping and spiral cine Displacement encoding (DENSE) sequences were acquired at three LV short-axis positions. Linear mixed modeling was used to define the association between regional LV mechanics from DENSE based on regional T1-derived diffuse …


Ambulatory Systolic Blood Pressure And Obesity Are Independently Associated With Left Ventricular Hypertrophic Remodeling In Children, Linyuan Jing, Christopher D. Nevius, Cassi M. Friday, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, H. Lester Kirchner, William J. Cochran, Gregory J. Wehner, Aftab S. Chishti, Christopher M. Haggerty, Brandon K. Fornwalt Nov 2017

Ambulatory Systolic Blood Pressure And Obesity Are Independently Associated With Left Ventricular Hypertrophic Remodeling In Children, Linyuan Jing, Christopher D. Nevius, Cassi M. Friday, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, H. Lester Kirchner, William J. Cochran, Gregory J. Wehner, Aftab S. Chishti, Christopher M. Haggerty, Brandon K. Fornwalt

Biomedical Engineering Faculty Publications

Background: Children with obesity have hypertrophic cardiac remodeling. Hypertension is common in pediatric obesity, and may independently contribute to hypertrophy. We hypothesized that both the degree of obesity and ambulatory blood pressure (ABP) would independently associate with measures of hypertrophic cardiac remodeling in children.

Methods: Children, aged 8–17 years, prospectively underwent cardiovascular magnetic resonance (CMR) and ABP monitoring. Left ventricular (LV) mass indexed to height2.7(LVMI), myocardial thickness and end-diastolic volume were quantified from a 3D LV model reconstructed from cine balanced steady state free precession images. Categories of remodeling were determined based on cutoff values for LVMI and …


Impaired Right Ventricular Contractile Function In Childhood Obesity And Its Association With Right And Left Ventricular Changes: A Cine Dense Cardiac Magnetic Resonance Study, Linyuan Jing, Arichanah Pulenthiran, Christopher D. Nevius, Abba Mejia-Spiegeler, Jonathan D. Suever, Gregory J. Wehner, H. Lester Kirchner, Christopher M. Haggerty, Brandon K. Fornwalt Jun 2017

Impaired Right Ventricular Contractile Function In Childhood Obesity And Its Association With Right And Left Ventricular Changes: A Cine Dense Cardiac Magnetic Resonance Study, Linyuan Jing, Arichanah Pulenthiran, Christopher D. Nevius, Abba Mejia-Spiegeler, Jonathan D. Suever, Gregory J. Wehner, H. Lester Kirchner, Christopher M. Haggerty, Brandon K. Fornwalt

Biomedical Engineering Faculty Publications

Background: Pediatric obesity is a growing public health problem, which is associated with increased risk of cardiovascular disease and premature death. Left ventricular (LV) remodeling (increased myocardial mass and thickness) and contractile dysfunction (impaired longitudinal strain) have been documented in obese children, but little attention has been paid to the right ventricle (RV). We hypothesized that obese/overweight children would have evidence of RV remodeling and contractile dysfunction.

Methods: One hundred and three children, ages 8–18 years, were prospectively recruited and underwent cardiovascular magnetic resonance (CMR), including both standard cine imaging and displacement encoding with stimulated echoes (DENSE) imaging, which allowed …


Shear Driven Micro-Fluidic Pump For Cardiovascular Applications, Nihad E. Daidzic Apr 2017

Shear Driven Micro-Fluidic Pump For Cardiovascular Applications, Nihad E. Daidzic

Aviation Department Publications

A valveless shear-driven micro-fluidic pump design (SDMFP) for hemodynamic applications is presented in this work. One of the possible medical and biomedical applications is in-vivo hemodynamic (human blood circulation) support/assist. One or more SDMFPs can be inserted/implanted into vascular lumens in a form of a stent/duct in series and/or in parallel (bypass duct) to support blood circulation in-vivo. A comprehensive review of various micro-pump designs up to about mid 2000’s is given in [1,2]. Many of micropump designs considered are not suitable for in-vivo or even in-vitro medical/biomedical applications.

Operating principles, design, and SDMFP features are given in [3]. A …


Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt Mar 2017

Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt

Electrical and Computer Engineering Faculty Publications

Background: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion.

Methods: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure …