Open Access. Powered by Scholars. Published by Universities.®

2013

Children's Mercy Kansas City

Sensitivity and Specificity

Articles 1 - 2 of 2

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators Oct 2013

Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

Echocardiographic image quality in Fontan survivors may be limited by a variety of factors. We sought to describe echocardiographic quality and factors associated with study quality in subjects participating in the Pediatric Heart Network Fontan Cross-Sectional Study. Echocardiograms were obtained at 7 clinical sites using a standard protocol. Quality grading and analysis were performed by a core laboratory. Univariate and multivariable modeling were performed to assess factors associated with quality and ability to obtain images sufficient for prespecified quantitative analysis. A total of 543 echocardiograms were obtained. The quality of echocardiograms improved over the duration of the study. The great …


Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali Aug 2013

Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position.

BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement.

METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography.

RESULTS: At baseline, …