Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Desulfovibrio Desulfuricans G20 Tetraheme Cytochrome Structure At 1.5 A˚ And Cytochrome Interaction With Metal Complexes, Mrunalini Pattarkine, J J. Tanner, C A. Bottoms, Y H. Lee, Judy D. Wall May 2006

Desulfovibrio Desulfuricans G20 Tetraheme Cytochrome Structure At 1.5 A˚ And Cytochrome Interaction With Metal Complexes, Mrunalini Pattarkine, J J. Tanner, C A. Bottoms, Y H. Lee, Judy D. Wall

Faculty Works

The structure of the type I tetraheme cytochrome c3 from Desulfovibrio desulfuricans G20 was determined to 1.5 A˚ by X-ray crystallography. In addition to the oxidized form, the structure of the molybdate-bound form of the protein was determined from oxidized crystals soaked in sodium molybdate. Only small structural shifts were obtained with metal binding, consistent with the remarkable structural stability of this protein. In vitro experiments with pure cytochrome showed that molybdate could oxidize the reduced cytochrome, although not as rapidly as U(VI) present as uranyl acetate. Alterations in the overall conformation and thermostability of the metal-oxidized protein were investigated …


Wavelet Analysis In Virtual Colonoscopy, Sharon Greenblum, Jiang Li, Adam Huang, Ronald M. Summers, Armando Manduca (Ed.), Amir A. Amini (Ed.) Jan 2006

Wavelet Analysis In Virtual Colonoscopy, Sharon Greenblum, Jiang Li, Adam Huang, Ronald M. Summers, Armando Manduca (Ed.), Amir A. Amini (Ed.)

Electrical & Computer Engineering Faculty Publications

The computed tomographic colonography (CTC) computer aided detection (CAD) program is a new method in development to detect colon polyps in virtual colonoscopy. While high sensitivity is consistently achieved, additional features are desired to increase specificity. In this paper, a wavelet analysis was applied to CTCCAD outputs in an attempt to filter out false positive detections. 52 CTCCAD detection images were obtained using a screen capture application. 26 of these images were real polyps, confirmed by optical colonoscopy and 26 were false positive detections. A discrete wavelet transform of each image was computed with the MATLAB wavelet toolbox using the …


Hybrid Committee Classifier For A Computerized Colonic Polyp Detection System, Jiang Li, Jianhua Yao, Nicholas Petrick, Ronald M. Summers, Amy K. Hara, Joseph M. Reinhardt (Ed.), Josien P.W. Pluim (Ed.) Jan 2006

Hybrid Committee Classifier For A Computerized Colonic Polyp Detection System, Jiang Li, Jianhua Yao, Nicholas Petrick, Ronald M. Summers, Amy K. Hara, Joseph M. Reinhardt (Ed.), Josien P.W. Pluim (Ed.)

Electrical & Computer Engineering Faculty Publications

We present a hybrid committee classifier for computer-aided detection (CAD) of colonic polyps in CT colonography (CTC). The classifier involved an ensemble of support vector machines (SVM) and neural networks (NN) for classification, a progressive search algorithm for selecting a set of features used by the SVMs and a floating search algorithm for selecting features used by the NNs. A total of 102 quantitative features were calculated for each polyp candidate found by a prototype CAD system. 3 features were selected for each of 7 SVM classifiers which were then combined to form a committee of SVMs classifier. Similarly, features …