Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

The Development And Psychometric Testing Of A Hypertension Knowledge Instrument In A Vulnerable Population, Crescent Elayne Rowell Dec 2010

The Development And Psychometric Testing Of A Hypertension Knowledge Instrument In A Vulnerable Population, Crescent Elayne Rowell

Theses and Dissertations (ETD)

The primary objective of the study was to assess the psychometric properties of a hypertension knowledge instrument in a vulnerable population. The secondary objective was to determine the association between hypertension knowledge and outcomes such as systolic and diastolic blood pressure and hemoglobin A1c.

A cross-sectional study was conducted using a convenience sample of 196 adults aged 18 years and older with hypertension. Item analysis was conducted to determine the reliability of the instrument. The factor structure was determined and confirmed using exploratory factor analysis and confirmatory factor analysis, respectively. Logistic regression analysis was used to determine the association between …


Effect Of Fixation Using Locked Compression Plate Versus Lag Screws On Biomechanics Of Talonavicular Joint: A Human Cadaveric Foot Model, Rahul Sudheer Ghotge Dec 2010

Effect Of Fixation Using Locked Compression Plate Versus Lag Screws On Biomechanics Of Talonavicular Joint: A Human Cadaveric Foot Model, Rahul Sudheer Ghotge

Theses and Dissertations (ETD)

Introduction: Talonavicular fusion is a surgery used for treating many hind foot pathologies. A problem associated with the procedure is non-union which may be due to inadequate stabilization. The objective of our study was to compare the effect of two surgical fixation techniques on the motion and biomechanics of the talonavicular joint in a human cadaveric foot model.

Materials and Methods: Thirteen human cadaveric foot specimens were prepared, mounted in a multi-axis programmable robot, and loaded using four loading scenarios. Each of the four loading scenarios consisted of a constant Achilles tendon load of 350N followed by either internal or …


A Passive Pure Moment Protocol For Testing Spine Segments: Development And Application, Kyle David Fraysur May 2010

A Passive Pure Moment Protocol For Testing Spine Segments: Development And Application, Kyle David Fraysur

Theses and Dissertations (ETD)

The pure moment protocol is the accepted standard for performing in-vitro biomechanical testing of spinal devices. Published studies predominantly report range of motion and flexibility data, but information regarding the segment center of rotation is also relevant. Most current pure moment platforms are not sensitive enough to accurately calculate the instantaneous axis of rotation (IAR) for a segment throughout a bending motion. The purpose of this study was to simulate a pure moment protocol using a programmable spine robot, and use the data gathered to calculate the IAR for harvested specimen and those implanted with a constrained total disc replacement …


The Use Of Preclinical Models To Improve The Treatment Of Retinoblastoma, Katie Marie Nemeth May 2010

The Use Of Preclinical Models To Improve The Treatment Of Retinoblastoma, Katie Marie Nemeth

Theses and Dissertations (ETD)

Rodent models play an essential role in the development of new chemotherapeutics and dosing regimes. It is often difficult to carryout a clinical study for pediatric cancers due to the small patient population. Retinoblastoma, a pediatric cancer of the eye, is one example of a pediatric cancer that can benefit from preclinical studies. Over the years various retinoblastoma rodent models have been developed used to test various combination of broad-spectrum systemic chemotherapy. It was found form these studies that the combination of topotecan and carboplatin was effective. However both drugs cause myelosuppression and therefore administrating both of these drugs systemically …


Development And Application Of Computational Tools For The Study And Optimization Of Variable Resolution X-Ray (Vrx) Computed Tomography Scanners, David Alejandro Rendon May 2010

Development And Application Of Computational Tools For The Study And Optimization Of Variable Resolution X-Ray (Vrx) Computed Tomography Scanners, David Alejandro Rendon

Theses and Dissertations (ETD)

The overall goal of this project was to develop and apply important computerized aids for the design and implementation of Variable Resolution X-ray (VRX) CT scanners developed at the University of Tennessee, Memphis. VRX scanners take advantage of the “projective compression” principle that allows the same device to image objects of very different sizes with the same level of detail by adjusting the field of view and the reconstruction resolution.

The first part of this project aimed to develop a set of computational tools specifically tailored for the design, implementation and study of VRX scanners. This included creating a reconstruction …


Preosteoblast Behavior On A Synthetic Calcium Phosphate Scaffold Coated With Cell Derived Matrix, Daniel A. Young May 2010

Preosteoblast Behavior On A Synthetic Calcium Phosphate Scaffold Coated With Cell Derived Matrix, Daniel A. Young

Theses and Dissertations (ETD)

Bone grafts are commonly used for the treatment of large bone defects. Biodegradable, synthetic bone grafts combined with cells and growth factors as a tissue engineered construct can provide benefits over the common autografts and allografts currently used. Calcium phosphate (CaP) materials offer high biocompatibility and chemical similarity to natural bone tissue. Biodegradable beta-tricalcium phosphate (β-TCP) scaffolds with an interconnected porous network have been created to promote tissue ingrowth and regeneration in vitro and in vivo. Extracellular matrix (ECM) coated on titanium and polymer scaffolds has been shown to improve cell response to those material surfaces. Here, we attempted …