Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 16 of 16

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Method Development And Validation Of The Quantitation Of 19 Antipsychotics Using Deuterated Internal Standards, Anthony S. Epps Dec 2011

Method Development And Validation Of The Quantitation Of 19 Antipsychotics Using Deuterated Internal Standards, Anthony S. Epps

Chemistry Theses

Antipsychotic drugs or neuroleptics are used primarily for psychiatric disorders such as schizophrenia, psychosis, and bipolar disorder. In forensic science antipsychotics are drugs of considerable interest because of their potential abuse, involvement in suicides, and they are frequently associated with sudden death investigations. Well-characterized and fully validated analytical data is necessary to generate reproducible and reliable results. As a result, data can be correctly interpreted and objectively demonstrate in its applicability for the intended use. This research has developed and validated a method that is selective, sensitive and accurate using liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the simultaneous determination of …


Evaluation Of Deformable Image Registration For Improved 4d Ct-Derived Ventilation For Image Guided Radiotherapy, Richard Castillo Dec 2011

Evaluation Of Deformable Image Registration For Improved 4d Ct-Derived Ventilation For Image Guided Radiotherapy, Richard Castillo

Dissertations & Theses (Open Access)

Recent treatment planning studies have demonstrated the use of physiologic images in radiation therapy treatment planning to identify regions for functional avoidance. This image-guided radiotherapy (IGRT) strategy may reduce the injury and/or functional loss following thoracic radiotherapy. 4D computed tomography (CT), developed for radiotherapy treatment planning, is a relatively new imaging technique that allows the acquisition of a time-varying sequence of 3D CT images of the patient's lungs through the respiratory cycle. Guerrero et al. developed a method to calculate ventilation imaging from 4D CT, which is potentially better suited and more broadly available for IGRT than the current standard …


Patient Safety: What Can Be Done About It?, Steven Dain Aug 2011

Patient Safety: What Can Be Done About It?, Steven Dain

Steven L Dain

Much is said and written about patient safety. In Canada, a small group of dedicated physicians, nurses and engineers participates in the Canadian Standards Association and Standards Council of Canada Advisory Committees writing basic safety and essential performance requirements for a large range of anesthesia, respiratory care and critical care equipment. Over the past several years, in recognition of the globalization of trade and the international nature of medical device design and manufacturing, Canadian Anesthesiologists’ Society members Dr Steven Dain, Dr Karen Brown, Dr Matt Kurrek, Dr Ken LeDez, and Dr Jeremy Sloan have primarily participated in Organization for International …


The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers Aug 2011

The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers

Dissertations & Theses (Open Access)

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within …


Mathematical Methods For Biosensor Models, Qi Wang Aug 2011

Mathematical Methods For Biosensor Models, Qi Wang

Doctoral

A biosensor is defined as a compact analytical device incorporating a biological sensing element integrated within a physico-chemical transducer whose aim is to produce optical or electronic signals proportional to the concentration of an analyte in a sample. Biosensors offer enormous potential to detect a wide range of analytes in health care, the food industry, environmental monitoring, security and defence. The beneficial impact on society as a result of the availability of such systems is immense, therefore investigating any strategy that could reduce development times and costs and reveal alternative designs is of utmost importance. In particular, mathematical modelling and …


Evaluation Of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due To Imrt Treatment Plan Complexity And Improperly Matched Dosimetry Data, Jacqueline R. Tonigan Aug 2011

Evaluation Of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due To Imrt Treatment Plan Complexity And Improperly Matched Dosimetry Data, Jacqueline R. Tonigan

Dissertations & Theses (Open Access)

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose …


Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam Aug 2011

Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam

Dissertations & Theses (Open Access)

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy.

Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the …


Synthesis And Analytical Evaluation Of Folate Conjugates For Use In Cancer Cell Detection, Pradipkumar Koshiya Apr 2011

Synthesis And Analytical Evaluation Of Folate Conjugates For Use In Cancer Cell Detection, Pradipkumar Koshiya

All Capstone Projects

Folate-targeted dyes have been used for the detection of tumor tissue and isolated cancer cells in both the animal tumor models as well as in human cancer patients. Folate receptors (FR) are abundantly present on several cancerous cell types but they are found less in normal human cells. There are several imaging agents that can be linked with folic acid and used for the detection of tumor. These imaging agents could be protein toxins, chemotherapeutic agents, gene therapy vectors, oligonucleotides, radioimaging agents, magnetic resonance imaging contrast agents and liposomes with entrapped drugs, radiotherapeutic agents and/or immunotherapeutic agents. This research showed …


Detection Of Protein By Microdrop Analysis, Yogeshkumar Radadiya Apr 2011

Detection Of Protein By Microdrop Analysis, Yogeshkumar Radadiya

All Capstone Projects

Analysis of protein depends particularly on protein concentration. Protein concentration measurement is the most important part in the research work to conduct protein-related studies. Although there are many methods available for this purpose, each method has certain limitations. The aim of the experiment is to develop either new or modified analytical method for the analysis and detection of protein using newly introduced micro-plate reader equipped with Take-3 microplate with the help of Gen-5 software. An ideal assay should be simple and easy to carry out. Another aspect to be taken into consideration are low inference, stability of measured components and …


Detection Of Folate Receptor From Fr+ Cancer Cells, Darpan Patel Apr 2011

Detection Of Folate Receptor From Fr+ Cancer Cells, Darpan Patel

All Capstone Projects

The aim was to detect cancer cells by using folate–PEG-Biotin probe with fluorescently labeled streptavidin for targeted drug delivery of anti-cancer drugs and diagnose cancer cells. Folate-PEG-Biotin (synthesized by Dr. Henne and Mr.Rohan Patel) was purified by HighPeformanceLiquidChromatography (HPLC) analysis and with the help of Liquid Chromatography/Mass Spectrometry (LC/MS) its identity was confirmed. Folate is a basic composition of cell metabolism in both synthesis of DNA and proteins. Growing cancer cells require high level of folic acid. Folate Receptor-α (FR-α) is a membrane bound protein having high affinity for folic acid and serves to transport of folate into cells. Poly …


Hemodynamics In The Stenosed Carotid Bifurcation With Plaque Ulceration, Emily Y. Wong Feb 2011

Hemodynamics In The Stenosed Carotid Bifurcation With Plaque Ulceration, Emily Y. Wong

Electronic Thesis and Dissertation Repository

The presence of irregular plaque surface morphology or ulceration of the atherosclerotic lesion has been identified as an independent risk factor for ischemic stroke. Doppler ultrasound (DUS) is the most commonly performed non-invasive technique used to assess patients suspected of having carotid artery disease, but currently does not incorporate the diagnosis of plaque ulceration. Advanced Doppler analyses incorporating quantitative estimates of flow disturbances may result in diagnostic indices that identify plaque ulcerative conditions. A technique for the fabrication of DUS-compatible flow phantoms was developed, using a direct-machining method that is amenable to comprehensive DUS investigations. In vitro flow studies in …


Photosensitizer Drug Delivery Via An Optical Fiber, Matibur Zamadar, Goutam Ghosh, Adaic Kapillai Mahendran, Mihaela Minnis, Bonnie I. Kruft, Ashwini Ghogare, David Aebisher, Alexander Greer Jan 2011

Photosensitizer Drug Delivery Via An Optical Fiber, Matibur Zamadar, Goutam Ghosh, Adaic Kapillai Mahendran, Mihaela Minnis, Bonnie I. Kruft, Ashwini Ghogare, David Aebisher, Alexander Greer

Faculty Publications

: An optical fiber has been developed with a maneuverable miniprobe tip that sparges O2 gas and photodetaches pheophorbide (sensitizer) molecules. Singlet oxygen is produced at the probe tip surface which reacts with an alkene spacer group releasing sensitizer upon fragmentation of a dioxetane intermediate. Optimal sensitizer photorelease occurred when the probe tip was loaded with 60 nmol sensitizer, where crowding of the pheophorbide molecules and self-quenching were kept to a minimum. The fiber optic tip delivered pheophorbide molecules and singlet oxygen to discrete locations. The 60 nmol sensitizer was delivered into petrolatum; however, sensitizer release was less efficient in …


An Integrated Computer-Aided Robotic System For Dental Implantation, Xiaoyan Sun, Yongki Yoon, Jiang Li, Frederic D. Mckenzie Jan 2011

An Integrated Computer-Aided Robotic System For Dental Implantation, Xiaoyan Sun, Yongki Yoon, Jiang Li, Frederic D. Mckenzie

Electrical & Computer Engineering Faculty Publications

This paper describes an integrated system for dental implantation including both preoperative planning utilizing computer-aided technology and automatic robot operation during the intra-operative stage. A novel two-step registration procedure was applied for transforming the preoperative plan to the operation of the robot, with the help of a Coordinate Measurement Machine (CMM). Experiments with a patient-specific phantom were carried out to evaluate the registration error for both position and orientation. After adopting several improvements, registration accuracy of the system was significantly improved. Sub-millimeter accuracy with the Target Registration Errors (TREs) of 0.38±0.16 mm (N=5) was achieved. The target orientation errors after …


On The Real-Time Performance, Robustness And Accuracy Of Medical Image Non-Rigid Registration, Yixun Liu Jan 2011

On The Real-Time Performance, Robustness And Accuracy Of Medical Image Non-Rigid Registration, Yixun Liu

Dissertations, Theses, and Masters Projects

Three critical issues about medical image non-rigid registration are performance, robustness and accuracy. A registration method, which is capable of responding timely with an accurate alignment, robust against the variation of the image intensity and the missing data, is desirable for its clinical use. This work addresses all three of these issues. Unacceptable execution time of Non-rigid registration (NRR) often presents a major obstacle to its routine clinical use. We present a hybrid data partitioning method to parallelize a NRR method on a cooperative architecture, which enables us to get closer to the goal: accelerating using architecture rather than designing …


Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie Jan 2011

Bcc Skin Cancer Diagnosis Based On Texture Analysis Techniques, Shao-Hui Chuang, Xiaoyan Sun, Wen-Yu Chang, Gwo-Shing Chen, Adam Huang, Jiang Li, Frederic D. Mckenzie

Electrical & Computer Engineering Faculty Publications

In this paper, we present a texture analysis based method for diagnosing the Basal Cell Carcinoma (BCC) skin cancer using optical images taken from the suspicious skin regions. We first extracted the Run Length Matrix and Haralick texture features from the images and used a feature selection algorithm to identify the most effective feature set for the diagnosis. We then utilized a Multi-Layer Perceptron (MLP) classifier to classify the images to BCC or normal cases. Experiments showed that detecting BCC cancer based on optical images is feasible. The best sensitivity and specificity we achieved on our data set were 94% …


Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.) Jan 2011

Prediction Of Brain Tumor Progression Using Multiple Histogram Matched Mri Scans, Debrup Banerjee, Loc Tran, Jiang Li, Yuzhong Shen, Frederic Mckenzie, Jihong Wang, Ronald M. Summers (Ed.), Bram Van Ginneken (Ed.)

Electrical & Computer Engineering Faculty Publications

In a recent study [1], we investigated the feasibility of predicting brain tumor progression based on multiple MRI series and we tested our methods on seven patients' MRI images scanned at three consecutive visits A, B and C. Experimental results showed that it is feasible to predict tumor progression from visit A to visit C using a model trained by the information from visit A to visit B. However, the trained model failed when we tried to predict tumor progression from visit B to visit C, though it is clinically more important. Upon a closer look at the MRI scans …