Open Access. Powered by Scholars. Published by Universities.®

Medical Specialties

PDF

Western University

Chromosomal aberrations

Articles 1 - 1 of 1

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan Sep 2020

Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan

Biochemistry Publications

Purpose: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the Dicentric Chromosome Assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole body irradiation has significantly improved throughput without compromising accuracy, however low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial body exposure determination.

Materials and Methods: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration …