Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Assessment Of Diastolic Function In Single-Ventricle Patients After The Fontan Procedure., Renee Margossian, Lynn A. Sleeper, Gail D. Pearson, Piers C. Barker, Luc Mertens, Michael D. Quartermain, Jason T. Su, Girish S. Shirali, Shan Chen, Steven D. Colan, Pediatric Heart Network Investigators Nov 2016

Assessment Of Diastolic Function In Single-Ventricle Patients After The Fontan Procedure., Renee Margossian, Lynn A. Sleeper, Gail D. Pearson, Piers C. Barker, Luc Mertens, Michael D. Quartermain, Jason T. Su, Girish S. Shirali, Shan Chen, Steven D. Colan, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: Patients with functional single ventricles after the Fontan procedure have abnormal cardiac mechanics. The aims of this study were to determine factors that influence diastolic function and to describe associations of diastolic function with current clinical status.

METHODS: Echocardiograms were obtained as part of the Pediatric Heart Network Fontan Cross-Sectional Study. Diastolic function grade (DFG) was assessed as normal (grade 0), impaired relaxation (grade 1), pseudonymization (grade 2), or restrictive (grade 3). Studies were also classified dichotomously (restrictive pattern present or absent). Relationships between DFG and pre-Fontan variables (e.g., ventricular morphology, age at Fontan, history of volume-unloading surgery) and …


Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker Jul 2016

Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: The accuracy of echocardiography in evaluating left ventricular contractility has not been validated in children. The objective of this study was to compare echocardiographic measures of contractility with those derived from pressure-volume loop (PVL) analysis in children.

METHODS: Patients with relatively normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. The gold-standard measure of contractility, end-systolic elastance (Ees), was obtained via balloon occlusion of one or both vena cavae. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Single-beat estimations of echocardiographic Ees were calculated using four different …


Effectiveness Of Pharmacist-Led Amiodarone Monitoring Services On Improving Adherence To Amiodarone Monitoring Recommendations: A Systematic Review, Dave L. Dixon, Steven P. Dunn, Michael S. Kelly, Timothy R. Mcllarky, Roy E. Brown Feb 2016

Effectiveness Of Pharmacist-Led Amiodarone Monitoring Services On Improving Adherence To Amiodarone Monitoring Recommendations: A Systematic Review, Dave L. Dixon, Steven P. Dunn, Michael S. Kelly, Timothy R. Mcllarky, Roy E. Brown

Pharmacy Faculty Articles and Research

Amiodarone remains the mostly frequently used antiarrhythmic in clinical practice and is most often used to maintain normal sinus rhythm in patients with atrial fibrillation who have failed a rate control strategy. Amiodarone has superior efficacy over other antiarrhythmics, a lower risk of torsade de pointes, and a better cardiovascular safety profile in patients with structural heart disease. However, amiodarone is associated with notable noncardiac toxicities affecting the thyroid, lungs, eyes, liver, and central nervous system. Since 2000, clinicians have been advised to follow amiodarone monitoring guidelines provided by the Heart Rhythm Society. Adherence to these recommendations in clinical practice, …