Open Access. Powered by Scholars. Published by Universities.®
Analytical, Diagnostic and Therapeutic Techniques and Equipment Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 2 of 2
Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment
Preliminary Results For A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi Depaor
Preliminary Results For A Monocular Marker-Free Gait Measurement System, Jane Courtney, Annraoi Depaor
Articles
This paper presents results from a novel monocular marker-free gait measurement system. The system was designed for physical and occupational therapists to monitor the progress of patients through therapy. It is based on a novel human motion capture method derived from model-based tracking. Testing is performed on two monocular, sagittal-view, sample gait videos – one with both the environment and the subject’s appearance and movement restricted and one in a natural environment with unrestricted clothing and motion. Results of the modelling, tracking and analysis stages are presented along with standard gait graphs and parameters.
Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack
Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack
Conference Papers
Indentation cutting may result in microcracking and main crack growth which was previously reported. In this study, we recorded the AE signals produced by cracking processes during cutting on cortical bone, measuring the cutting force and correlating between load-displacement curves and AE activities.