Full-Text Articles in Analytical, Diagnostic and Therapeutic Techniques and Equipment

Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker Jul 2016

Validation Of Noninvasive Measures Of Left Ventricular Mechanics In Children: A Simultaneous Echocardiographic And Conductance Catheterization Study., Shahryar M. Chowdhury, Ryan J. Butts, Carolyn L. Taylor, Varsha M. Bandisode, Karen S. Chessa, Anthony M. Hlavacek, Girish S. Shirali, G Hamilton Baker

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: The accuracy of echocardiography in evaluating left ventricular contractility has not been validated in children. The objective of this study was to compare echocardiographic measures of contractility with those derived from pressure-volume loop (PVL) analysis in children.

METHODS: Patients with relatively normal loading conditions undergoing routine left heart catheterization were prospectively enrolled. PVLs were obtained via conductance catheters. The gold-standard measure of contractility, end-systolic elastance (Ees), was obtained via balloon occlusion of one or both vena cavae. Echocardiograms were performed immediately after PVL analysis under the same anesthetic conditions. Single-beat estimations of echocardiographic Ees were calculated using four different …


Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators Oct 2013

Factors Impacting Echocardiographic Imaging After The Fontan Procedure: A Report From The Pediatric Heart Network Fontan Cross-Sectional Study., Richard V. Williams, Renee Margossian, Minmin Lu, Andrew M. Atz, Timothy J. Bradley, Michael Jay Campbell, Steven D. Colan, Dianne Gallagher, Wyman W. Lai, Gail D. Pearson, Ashwin Prakash, Girish S. Shirali, Meryl S. Cohen, Pediatric Heart Network Investigators

Manuscripts, Articles, Book Chapters and Other Papers

Echocardiographic image quality in Fontan survivors may be limited by a variety of factors. We sought to describe echocardiographic quality and factors associated with study quality in subjects participating in the Pediatric Heart Network Fontan Cross-Sectional Study. Echocardiograms were obtained at 7 clinical sites using a standard protocol. Quality grading and analysis were performed by a core laboratory. Univariate and multivariable modeling were performed to assess factors associated with quality and ability to obtain images sufficient for prespecified quantitative analysis. A total of 543 echocardiograms were obtained. The quality of echocardiograms improved over the duration of the study. The great …


Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali Aug 2013

Early Echocardiographic Changes After Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve In The Pulmonary Position., Shahryar M. Chowdhury, Ziyad M. Hijazi, John Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Lydia King, Jodi Akin, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: To evaluate echocardiographic changes after SAPIEN valve implantation in the pulmonary position.

BACKGROUND: The feasibility of the SAPIEN transcatheter pulmonary valve (TPV) has recently been demonstrated. We evaluated changes in pulmonary valve function and the right ventricle after SAPIEN TPV placement.

METHODS: We evaluated echocardiograms at baseline, discharge, 1 and 6 months after TPV placement in 33 patients from 4 centers. Pulmonary insufficiency severity was graded 0-4. TPV peak and mean gradients were measured. Right ventricular (RV) size and function were quantified using routine measures derived from color, spectral, and tissue Doppler indices and two-dimensional echocardiography.

RESULTS: At baseline, …


Dobutamine Stress Echocardiography For Assessing Coronary Artery Disease After Transplantation In Children., R L. Larsen, P M. Applegate, D A. Dyar, P A. Ribeiro, S D. Fritzsche, N F. Mulla, Girish S. Shirali, M A. Kuhn, R E. Chinnock, P M. Shah Aug 1998

Dobutamine Stress Echocardiography For Assessing Coronary Artery Disease After Transplantation In Children., R L. Larsen, P M. Applegate, D A. Dyar, P A. Ribeiro, S D. Fritzsche, N F. Mulla, Girish S. Shirali, M A. Kuhn, R E. Chinnock, P M. Shah

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: The purpose of this study was to determine the feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography (DSE) for evaluating posttransplant coronary artery disease (TxCAD) in children, and to determine the frequency of selected cardiac events after normal or abnormal DSE.

BACKGROUND: Posttransplant coronary artery disease is the most common cause of graft loss (late death or retransplantation) after cardiac transplantation (CTx) in children. Coronary angiography, routinely performed to screen for TxCAD, is an invasive procedure with limited sensitivity. The efficacy of DSE for detecting atherosclerotic coronary artery disease is established, but is unknown in children after CTx. …