Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal
Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal
Electronic Thesis and Dissertation Repository
Introduction: The most common method of spinal fusion includes pedicle screws instrumentation, either with or without interbody cage fusion. This thesis aimed to develop and test a novel stand-alone intervertebral device that eliminates the need for pedicle screws and rods.
Method: The stand-alone cage was designed in collaboration with spinal surgeons and engineers using computer assisting drawings, and manufactured in titanium by 3D printing. Biomechanical testing comparing the stand-alone cage with standard posterior lumbar interbody fusion (PLIF) in sawbones (n=6) and cadavers (n=8).
Result: Compared to PLIF, the stand-alone cage demonstrated no significant difference in range of flexion, lateral bend …