Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Medicine and Health Sciences

Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan Dec 2018

Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan

Electronic Thesis and Dissertation Repository

Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.

Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …


Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan Nov 2018

Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan

Electronic Thesis and Dissertation Repository

Tibiotalar arthrodesis is a surgical procedure, used for the treatment of end-stage ankle arthrosis and instability. There are dozens of described procedures in the literature, all with varying rates of success. Two of the most common reasons for reoperation in tibiotalar arthrodesis are nonunion and infection; few studies have established any associations between patient/surgical factors and reoperation for nonunion and infection.

The first part of this thesis focuses on determining the rate of reoperation to the ipsilateral lower limb and if any patient/surgical factors are associated with reoperation for nonunion and infection. The second part of this thesis turns attention …


Collared Vs. Collarless Total Hip Arthroplasty In Both Direct Anterior And Direct Lateral Approach Surgery: A Prospective Cohort Comparison Study, Seb Heaven Nov 2018

Collared Vs. Collarless Total Hip Arthroplasty In Both Direct Anterior And Direct Lateral Approach Surgery: A Prospective Cohort Comparison Study, Seb Heaven

Electronic Thesis and Dissertation Repository

Total hip arthroplasty (THA) is one of the most successful surgical procedures performed worldwide. Recent advances in implant technology and popularization of the muscle-sparing Direct Anterior (DA) approach to the hip has led to younger patients becoming candidates for hip arthroplasty surgery. Among the many considerations necessary for success in this patient population, implant design plays an important role in determining outcomes.

In this thesis, we prospectively evaluated patients who received a collared or collarless fully hydroxyapatite-coated femoral stem during THA with a standard RSA protocol to assess stem migration patterns following surgery.

Preliminary results indicate that collarless stems subside …


Revision Total Knee Arthroplasty Using A Novel 3d Printed Titanium Augment: A Cadaveric Biomechanical Study, Charles-Antoine Dion Nov 2018

Revision Total Knee Arthroplasty Using A Novel 3d Printed Titanium Augment: A Cadaveric Biomechanical Study, Charles-Antoine Dion

Electronic Thesis and Dissertation Repository

During revision total knee arthroplasty (rTKA), proximal tibial bone loss is frequently encountered and can result in a less-stable bone-implant fixation. A 3D printed titanium augment that conforms to the irregular shape of the proximal tibia was recently developed. The purpose of this study was to evaluate the fixation stability of rTKA with this augment in comparison to conventional cemented rTKA.

Fixation stability testing was conducted on eleven pairs of thawed fresh-frozen cadaveric tibias (22 tibias) after primary and revision TKA. During the loading protocol, the bone-implant micromotion was measured using a high-resolution optical system.

There was significantly less micromotion …


Wearable Sensors And Total Knee Arthroplasty: Assessing Quantitative Function To Improve The Patient Experience, Megan Fennema Oct 2018

Wearable Sensors And Total Knee Arthroplasty: Assessing Quantitative Function To Improve The Patient Experience, Megan Fennema

Electronic Thesis and Dissertation Repository

Osteoarthritis (OA) is a chronic degenerative disease for which the only long-term solution is total knee arthroplasty (TKA), though many patients are not satisfied with their TKA. Satisfaction in TKA patients is not well understood. Subjective questionnaires and objective functional tests have been previously used to assess TKA outcomes, but both have disadvantages. Wearable sensors have facilitated affordable biomechanical measurement in OA and TKA populations. The objective of this work was to use wearable sensors alongside functional tests with TKA patients to identify quantitative function that related to subjective function and satisfaction. A wearable sensor-setup was validated before implementation in …


The Impact Of Free Radical Stabilization Techniques On In Vivo Property Changes In Highly Cross-Linked Polyethylene Acetabular Liners, Michael M. Decker . Oct 2018

The Impact Of Free Radical Stabilization Techniques On In Vivo Property Changes In Highly Cross-Linked Polyethylene Acetabular Liners, Michael M. Decker .

Electronic Thesis and Dissertation Repository

Highly cross-linked polyethylene (HXLPE) was introduced into total hip arthroplasty (THA) to reduce long-term wear-related complications. However, HXLPE production and in vivo oxidation can alter mechanical behavior. Mechanical failure of HXLPE liners at the implant rim have been reported. The purpose of this thesis is to determine if thermal free radical stabilization techniques used in HXLPE production alter the mechanical properties, physical properties and oxidative stability of liner rims after extended in vivo time.

Retrieved remelted, single annealed and sequentially annealed HXLPE liner rims were mechanically tested using a validated microindentation technique. Oxidation and crystalline phase composition were measured. Results …


Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal Jun 2018

Design, Development, Manufacturing And Biomechanical Testing Of Stand-Alone Cage For Posterior Lumbar Interbody Fusion, Fahad Alhelal

Electronic Thesis and Dissertation Repository

Introduction: The most common method of spinal fusion includes pedicle screws instrumentation, either with or without interbody cage fusion. This thesis aimed to develop and test a novel stand-alone intervertebral device that eliminates the need for pedicle screws and rods.

Method: The stand-alone cage was designed in collaboration with spinal surgeons and engineers using computer assisting drawings, and manufactured in titanium by 3D printing. Biomechanical testing comparing the stand-alone cage with standard posterior lumbar interbody fusion (PLIF) in sawbones (n=6) and cadavers (n=8).

Result: Compared to PLIF, the stand-alone cage demonstrated no significant difference in range of flexion, lateral bend …