Ligation Of The Outflow Graft Of The Left Ventricular Assist Device For Management Of Hemolysis Due To Pump Thrombosis, Jean Touchan, Alexis Shafii, Maya Guglin Sep 2016

Ligation Of The Outflow Graft Of The Left Ventricular Assist Device For Management Of Hemolysis Due To Pump Thrombosis, Jean Touchan, Alexis Shafii, Maya Guglin

The VAD Journal

Pump thrombosis is a serious complication of continuous-flow left ventricular assist devices (LVAD). Treatment options include medical thrombolysis, surgical pump exchange or urgent heart transplantation. We are reporting a case of pump thrombosis with active hemolysis and acute renal failure managed surgically by isolating the LVAD while awaiting renal recovery and donor heart availability.


Caregiver Burden Is Low Nine To Twelve Months After Ventricular Assist Device Implantation, Roxana Ghashghaei, Hao Tran, Jorge Silva, Barry H. Greenberg, Denise Barnard, Eric Adler Sep 2016

Caregiver Burden Is Low Nine To Twelve Months After Ventricular Assist Device Implantation, Roxana Ghashghaei, Hao Tran, Jorge Silva, Barry H. Greenberg, Denise Barnard, Eric Adler

The VAD Journal

Background:

Prior studies have found that caregivers of chronically ill patients, including those with heart failure, have significant stress and burden. Ventricular Assist Devices (VADs) are a promising therapeutic modality for end stage heart failure. However, caregiver burden has not previously been studied in the caregivers of VAD patients.

Methods:

We studied 31 caregivers of VAD patients receiving care at University of California, San Diego. Validated instruments tools, such as the Bakas Caregiving Outcomes scale and Oberst Caregiving Demand and Difficulty sub-scales, were used to measure the caregivers’ psychological burden.

Results:

Nearly half of the caregivers were the patient’s spouse …


Acute Appendicitis: A Potential Complication Of Continuous-Flow Left Ventricular Assist Device Support, Joshua S. Roark, Akinniran A. Abisogun, Jason N. Katz Aug 2016

Acute Appendicitis: A Potential Complication Of Continuous-Flow Left Ventricular Assist Device Support, Joshua S. Roark, Akinniran A. Abisogun, Jason N. Katz

The VAD Journal

Acute appendicitis, while common in younger patients, is an unusual cause for hospitalization among older adults. We report a case series of 3 individuals who had been previously implanted with a continuous-flow left ventricular assist device (CF-LVAD) for end-stage heart failure, and who subsequently developed acute appendicitis. Both axial-flow technology and nonpulsatile systemic blood flow have been implicated as potential causes for bleeding and thrombosis in contemporary LVAD populations(1-3). This case series represents the first report of acute appendicitis as an adverse event following LVAD implantation and represents a patient demographic that would historically be at very low-risk for this …


Total Artificial Heart Imaging And Complications: A Pictorial Review, Carrie K. Gomez, Susan K. Hobbs Aug 2016

Total Artificial Heart Imaging And Complications: A Pictorial Review, Carrie K. Gomez, Susan K. Hobbs

The VAD Journal

Heart failure is a serious cause of morbidity and mortality with many patients ultimately requiring heart transplantation. As the rate of heart failure continues to increase and surpass the number of available donor hearts, the need for cardiac assist devices is rapidly rising. The total artificial heart has emerged as an effective therapeutic option in patients with end-stage biventricular heart failure who are awaiting orthotopic heart transplantation. The TAH replaces the patient’s native ventricle and valves and has one of the highest bridge to transplant rates. Many complications have been associated with the TAH including infections, bleeding, thrombosis, device malfunction, …


Incidence Of Pump Thrombosis In Heartmate Ii During Destination Therapy, Rohan Samson, Abhishek Jaiswal, Frank Smart, Thierry H. Lejemtel Jul 2016

Incidence Of Pump Thrombosis In Heartmate Ii During Destination Therapy, Rohan Samson, Abhishek Jaiswal, Frank Smart, Thierry H. Lejemtel

The VAD Journal

Pump thrombosis (PT) occurs during destination therapy (DT) with HeartMate II, a continuous blood flow left ventricular assist device (St Jude, Pleasanton, CA, USA). With adherence to stringent post-operative and long-term anticoagulation a low incidence of PT was initially reported during DT. The increased PT incidence during DT that was reported in early 2013 was attributed to lenient anticoagulation. A wide range of PT incidence during DT is being reported since the return to stringent post-operative and long-term anticoagulation. We searched PubMed from January 2008 to February 2016 for reports of PT during mechanical circulatory support with HeartMate II and …


Normal Lactate Dehydrogenase Does Not Exclude Pump Thrombosis In Left Ventricular Assist Devices, Julie Shelton Do, Bennet George Md, Amanda Hart Bsn, Rn, Maya Guglin Md Jun 2016

Normal Lactate Dehydrogenase Does Not Exclude Pump Thrombosis In Left Ventricular Assist Devices, Julie Shelton Do, Bennet George Md, Amanda Hart Bsn, Rn, Maya Guglin Md

The VAD Journal

Left ventricular assist device (LVAD) pump thrombosis is a well-known complication of LVAD placement. Elevated lactate dehydrogenase (LDH) has classically been the first objective marker of pump thrombosis. In this case, we present a patient found to have normal serum LDH values but was ultimately found to have significant pump thrombosis.


Outcomes Of External Repair Of Heartmate Ii™ Lvad Percutaneous Leads, Jay D. Pal, Claudius Mahr, Jason W. Smith, Todd F. Dardas, Jay Pinette, David J. Farrar, Nahush A. Mokadam Jun 2016

Outcomes Of External Repair Of Heartmate Ii™ Lvad Percutaneous Leads, Jay D. Pal, Claudius Mahr, Jason W. Smith, Todd F. Dardas, Jay Pinette, David J. Farrar, Nahush A. Mokadam

The VAD Journal

Background: The HeartMate II Left Ventricular Assist Device (LVAD) receives power via a percutaneous lead connected to an external controller and batteries. At times, this lead can be damaged during normal wear, as well as by traumatic fracture, which may jeopardize the functionality of the LVAD. If there is significant internal damage, surgical replacement of the LVAD is required. However it is possible to repair externally damaged leads by replacing the distal portion of the lead to avoid pump replacement. We report the overall experience and outcomes in patients with external lead repairs.

Methods: A procedure for full …


Exploring Body Mass Index Changes In Left Ventricular Assist Device Patients, Raquel E. Thomas, Corrine Hanson, Glenda Woscyna, Brian D. Lowes Jun 2016

Exploring Body Mass Index Changes In Left Ventricular Assist Device Patients, Raquel E. Thomas, Corrine Hanson, Glenda Woscyna, Brian D. Lowes

The VAD Journal

Background: Current treatment options for end-stage heart failure, such as transplantation, can be limited by obesity guidelines. Mechanical devices such as Left Ventricular Assistive Devices (LVAD) can bridge heart failure patients to transplantation, however, after implantation; some patients may experience weight gain that precludes them from transplantation. Therefore, the objective of this study was to evaluate weight changes after the implantation of an LVAD.

Methods: A retrospective review of 130 patients receiving an LVAD were divided into two groups based on BMI at the time of implantation: obese (>30 kg/m2) and non-obese (/m2). Patients were …


A Protocol For Collecting Human Cardiac Tissue For Research, Cheavar A. Blair, Premi Haynes, Stuart G. Campbell, Charles Chung, Mihail I. Mitov, Donna Dennis, Mark R. Bonnell, Charles W. Hoopes, Maya Guglin, Kenneth S. Campbell Jun 2016

A Protocol For Collecting Human Cardiac Tissue For Research, Cheavar A. Blair, Premi Haynes, Stuart G. Campbell, Charles Chung, Mihail I. Mitov, Donna Dennis, Mark R. Bonnell, Charles W. Hoopes, Maya Guglin, Kenneth S. Campbell

The VAD Journal

This manuscript describes a protocol at the University of Kentucky that allows a translational research team to collect human myocardium that can be used for biological research. We have gained a great deal of practical experience since we started this protocol in 2008, and we hope that other groups might be able to learn from our endeavors. To date, we have procured ~4000 samples from ~230 patients. The tissue that we collect comes from organ donors and from patients who are receiving a heart transplant or a ventricular assist device because they have heart failure. We begin our manuscript by …


The Utility Of Remote Hemodynamic Monitoring Devices In Patients With A Ventricular Assist Device, Bennet George, Amanda Hart, Sarah Branam, Maya Guglin May 2016

The Utility Of Remote Hemodynamic Monitoring Devices In Patients With A Ventricular Assist Device, Bennet George, Amanda Hart, Sarah Branam, Maya Guglin

The VAD Journal

Remote intracardiac hemodynamic monitoring is a growing area of interest to help aid in the management of patients with chronic congestive heart failure. The utility of remote hemodynamic monitoring has not previously been investigated with a ventricular assist device population. We present two cases of patients with ventricular assist devices in which we employed remote hemodynamic monitoring data to aid in patient management.


Speech At The Reception For Dr. Frazier At The Ishlt 2016. Remarks For O.H. Frazier, M.D., Edwin C. Mcgee Jr May 2016

Speech At The Reception For Dr. Frazier At The Ishlt 2016. Remarks For O.H. Frazier, M.D., Edwin C. Mcgee Jr

The VAD Journal

No abstract provided.


Orthotopic Heart Transplant Following Implantation Of A Systemic Ventricular Assist Device In A Patient With Congenitally Corrected Transposition Of The Great Arteries And Dextrocardia Situs Inversus Totalis, Bree Ann C. Young, Zachariah B. Nealy, Michael F. Mcgrath, John M. Herre May 2016

Orthotopic Heart Transplant Following Implantation Of A Systemic Ventricular Assist Device In A Patient With Congenitally Corrected Transposition Of The Great Arteries And Dextrocardia Situs Inversus Totalis, Bree Ann C. Young, Zachariah B. Nealy, Michael F. Mcgrath, John M. Herre

The VAD Journal

Congenitally corrected transposition of the great arteries (CCTGA) is a rare congenital heart disease that commonly results in congestive heart failure due to exposure of the anatomic right ventricle to systemic pressures. Additional anatomic abnormalities, such as situs inversus, in which the viscera are mirror images of normal anatomy, or dextrocardia in which the heart apex is located on the patient’s right, once were contraindications to transplant in the treatment of advanced heart failure. However, recent advancements now allow for the management of heart failure through mechanical circulatory support and subsequent transplant. This case presents a 52 year-old man with …


Va-Ecmo In Cardiogenic Shock In Adults: Indications And Outcomes, Maya Guglin, Andrew Burchett May 2016

Va-Ecmo In Cardiogenic Shock In Adults: Indications And Outcomes, Maya Guglin, Andrew Burchett

The VAD Journal

Background

Use of veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) has become increasingly common as a means of providing hemodynamic support for patients in cardiogenic shock. Data regarding the efficacy of VA-ECMO are provided almost exclusively by single-center, retrospective analyses. These retrospective analyses vary significantly with regards to documentation of the underlying pathophysiologic process resulting in cardiogenic shock.

Methods

Relevant published studies were identified by using a comprehensive search of English-language MEDLINE from 1966 to November 2015. Relevant references found cited in these studies were also analyzed. These studies were analyzed with regard to the indications the authors used for initiation of …


Bleeding And Thromboembolic Events In Patients With Heartmate Ii Mechanical Circulatory Support, Salman Allana, Carrie Chapman, Nancy Sweitzer, Maryl Johnson, Takushi Kohmoto, Margaret Murray, David Murray, Zhanhai Li, Peter S. Rahko Apr 2016

Bleeding And Thromboembolic Events In Patients With Heartmate Ii Mechanical Circulatory Support, Salman Allana, Carrie Chapman, Nancy Sweitzer, Maryl Johnson, Takushi Kohmoto, Margaret Murray, David Murray, Zhanhai Li, Peter S. Rahko

The VAD Journal

Background: Bleeding and thromboembolic events (TE) are common complications following HeartMate II (HMII) implantation. The aim of the study was to review our experience related to bleeding and TE events in patients with a HMII and identify factors associated with increased risk of these events.

Methods: We retrospectively reviewed 70 consecutive patients who received a HMII between May 2006 and December 2011. The patients were followed for 12 months or until cardiac transplantation, device explantation or death. Major bleeding was defined by INTERMACS criteria with intracranial bleeding events added.

Results: There were 48 bleeding events in 28 (40%) patients with …


Lung Edema On Va Ecmo, Christof Schmid Md Mar 2016

Lung Edema On Va Ecmo, Christof Schmid Md

The VAD Journal

No abstract provided.


Temporary And Durable Mechanical Circulatory Support For Single Ventricular Failure In An Adult, Joshua L. Hermsen, Jason W. Smith, Jay D. Pal, Agustin Rubio, S. Carolina Masri, Nahush A. Mokadam, Richard K. Cheng, Claudius Mahr Mar 2016

Temporary And Durable Mechanical Circulatory Support For Single Ventricular Failure In An Adult, Joshua L. Hermsen, Jason W. Smith, Jay D. Pal, Agustin Rubio, S. Carolina Masri, Nahush A. Mokadam, Richard K. Cheng, Claudius Mahr

The VAD Journal

Patients palliated with Fontan circulation requiring mechanical circulatory support pose anatomic and physiologic challenges. We treated a Fontan patient with acute ventricular failure with sequential temporary and durable support devices. Aspects of treatment with each device required modification based on the patient’s anatomy and physiology.


Decrease In Driveline Infections With Change In Driveline Management Protocol, Saima Aslam, Jennifer Dan, Amanda Topik, Michael Belyk, Francesca Torriani, Randy Taplitz, Jorge Silva-Enciso, Denise Barnard, Barry Greenberg, Jack Copeland, Victor Pretorius, Eric Adler Mar 2016

Decrease In Driveline Infections With Change In Driveline Management Protocol, Saima Aslam, Jennifer Dan, Amanda Topik, Michael Belyk, Francesca Torriani, Randy Taplitz, Jorge Silva-Enciso, Denise Barnard, Barry Greenberg, Jack Copeland, Victor Pretorius, Eric Adler

The VAD Journal

Background: Driveline infections (DLI) are a significant cause of morbidity and mortality in ventricular assist device (VAD) recipients. We compared driveline infection (DLI) rate after an institutional change in driveline management protocol.

Methods: We retrospectively reviewed records of left VAD recipients at our institution, based on driveline management. Group 1: daily driveline dressing change consisting of chlorhexidine cleansing, sterile 4x4 gauze, and use of an abdominal binder. Group 2: Dressing change every 3 days consisting of chlorhexidine cleansing, non-sterile silver-impregnated foam with overlying clear dressing, and use of a driveline anchor. Follow-up was censored at first DLI, device removal, transplant …


Pulmonary Congestion (White Lungs) On Va Ecmo, Maya Guglin, Andrew Burchett, Thomas Tribble, Richard Charnigo Mar 2016

Pulmonary Congestion (White Lungs) On Va Ecmo, Maya Guglin, Andrew Burchett, Thomas Tribble, Richard Charnigo

The VAD Journal

Veno-arterial extracorporeal membrane oxygenation therapy (VA ECMO) is used for short-term circulatory support in the setting of cardiogenic shock or cardiac arrest. While VA-ECMO improves hemodynamics and gas exchange, it may result in left ventricular distention and pulmonary congestion.

Methods

The records of all patients supported with VA ECMO for at least three consecutive days at our institution from 2012-2014 were retrospectively analyzed. All chest radiographs taken during VA ECMO support were graded on a scale of 1 to 4. A score of 1 was used when no pulmonary congestion was present. A score of 2 was used for congestion …


Development And Pilot-Testing Of A Patient Decision Aid For Left Ventricular Assist Device Placement, Kristin Kostick, Estevan D. Delgado, Lidija A. Wilhelms, Courtenay R. Bruce, Jerry D. Estep, Matthias Loebe, Charles Minard, Jennifer S. Blumenthal-Barby Feb 2016

Development And Pilot-Testing Of A Patient Decision Aid For Left Ventricular Assist Device Placement, Kristin Kostick, Estevan D. Delgado, Lidija A. Wilhelms, Courtenay R. Bruce, Jerry D. Estep, Matthias Loebe, Charles Minard, Jennifer S. Blumenthal-Barby

The VAD Journal

Objectives: This paper describes the development methodology and pilot-testing of a decision aid for Left Ventricular Assist Device (LVAD) placement, combining traditional needs-assessment with a novel user-centered approach.

Background: Studies indicate suboptimal patient understanding of the capabilities, lifestyle implications, and risks of LVAD therapy.

Methods and Results: We developed the decision aid in line with the Ottawa Decision Support Framework (ODSF) and the International Patient Decision Aids Standards (IPDAS) for ensuring quality, patient-centered content. Structured interviews were conducted with patients, caregivers, candidates for LVAD treatment, and expert clinicians (n=71) to generate content based on patient values and …


What Did We Learn About Vads In 2015?, Maya Guglin Feb 2016

What Did We Learn About Vads In 2015?, Maya Guglin

The VAD Journal

No abstract provided.


Low-Dose Vitamin K Can Improve Warfarin Control In Patients On Lvad Support, Daizo Tanaka, Venessa L. Kotch, Cheryl Abbas, Gordon Reeves, John Wc Entwistle Iii Nov 2015

Low-Dose Vitamin K Can Improve Warfarin Control In Patients On Lvad Support, Daizo Tanaka, Venessa L. Kotch, Cheryl Abbas, Gordon Reeves, John Wc Entwistle Iii

The VAD Journal

Background

Anticoagulation with oral vitamin K antagonists (VKA) is very important in patients supported on a left ventricular assist device (LVAD) to prevent thromboembolic complications. Some patients tolerate VKAs poorly and have an unstable INR as a result. It is reported that low-dose vitamin K can improve INR control in patients with an unstable INR in other clinical settings. We evaluated its safety and effectiveness in patients on LVAD support.

Methods

The records of all patients supported on an implantable LVAD between January, 2013 and March, 2014 were reviewed retrospectively to identify those who had received low-dose vitamin K while …


Damaging Cardiac And Cancer Genetic Variants In The Lvad Population, Brian D. Lowes Md, Phd, Eric T. Rome, Kajari Dhar, Jeff Kittrell, James D. Eudy, John Y. Um, Alexandra Moulton, J. Zao, Ronald Redder, Michael J. Moulton, Daniel R. Anderson, Eugenia Raichlin Nov 2015

Damaging Cardiac And Cancer Genetic Variants In The Lvad Population, Brian D. Lowes Md, Phd, Eric T. Rome, Kajari Dhar, Jeff Kittrell, James D. Eudy, John Y. Um, Alexandra Moulton, J. Zao, Ronald Redder, Michael J. Moulton, Daniel R. Anderson, Eugenia Raichlin

The VAD Journal

Background: Next generation sequencing technology, coupled with population genetic databases, have made broad genetic evaluation relatively inexpensive and widely available. Our objective was to assess the prevalence of potentially damaging cancer and cardiac gene variants in advanced non-ischemic cardiomyopathy patients.

Methods: Explanted human heart tissue procured at LVAD placement was obtained from the University of Nebraska Medical Center Heart Tissue Bank. Genomic DNA was isolated from tissues and amplified by PCR using targeted ampliseq primer pools from an inherited disease panel. Individual libraries were amplified by emulsion PCR on Ion Sphere particles and sequencing was performed on a …


Early Manifestations Of Atrial Tamponade In A Patient Implanted With Syncardia Total Artificial Heart., Manoj Thangam, Bindu Akkanti, Sriram Nathan, Daniel Ocazionez-Trujillo, Indranee Rajapreyar, Manish K. Patel, Jayesh Patel, Pranav Loyolka, Biswajit Kar, Igor Gregoric Oct 2015

Early Manifestations Of Atrial Tamponade In A Patient Implanted With Syncardia Total Artificial Heart., Manoj Thangam, Bindu Akkanti, Sriram Nathan, Daniel Ocazionez-Trujillo, Indranee Rajapreyar, Manish K. Patel, Jayesh Patel, Pranav Loyolka, Biswajit Kar, Igor Gregoric

The VAD Journal

Implantation rates of the SynCardia Total Artificial Heart (TAH) system is growing owing to the increasing incidence of biventricular heart failure and the limited number of transplantable hearts. Among the complications associated with the device, atrial tamponade is an emergent condition that requires immediate attention. Atrial tamponade occurs when increasing pericardial hemorrhage leads to atrial compression that produces tamponade physiology and compromises cardiac output. Unfortunately to our knowledge, information concerning the early manifestations of tamponade in TAH patients is extremely scarce. Previous reports have focused on decreased cardiac output as an indicator of tamponade. However, other presentations including pulmonary decompensation …


Massive Pulmonary Embolism With Hemodynamic Compromise Successfully Treated With Veno-Arterial Extracorporeal Membrane Oxygenation, B. Akkanti, S. Nathan, E. N. Centeno, K. Akasapu, P. Doshi, R. Hussain, F. Raissi, A. Nascimbene, R. Srinivasan, I. Rajapreyar, M. Patel, J. Patel, M. Akay, P. Loyalka, B. Kar, I. Gregoric Oct 2015

Massive Pulmonary Embolism With Hemodynamic Compromise Successfully Treated With Veno-Arterial Extracorporeal Membrane Oxygenation, B. Akkanti, S. Nathan, E. N. Centeno, K. Akasapu, P. Doshi, R. Hussain, F. Raissi, A. Nascimbene, R. Srinivasan, I. Rajapreyar, M. Patel, J. Patel, M. Akay, P. Loyalka, B. Kar, I. Gregoric

The VAD Journal

Introduction: Cardiogenic shock that results from pulmonary embolus has a high mortality rate. Systemic thrombolysis is frequently used in submassive and massive pulmonary embolus and has been shown to restore circulation. However, in the event of impending or ongoing cardiac arrest, systemic thrombolysis or anticoagulation alone has not been always shown to be effective. Case reports have previously established that extracorporeal membrane oxygenation can effectively be used as an effective rescue strategy in cases of cardiac arrest as a result from massive pulmonary embolus. We report six cases of massive pulmonary embolism (PE), in which veno-arterial extracorporeal membrane oxygenation (VA …


Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment., Manoj Thangam, Bindu Akkanti, Maan Malahafio, Sriram Nathan, Indranee Rajapreyar, Pranav Loyalka, Biswajit Kar, Igor Gregoric Aug 2015

Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment., Manoj Thangam, Bindu Akkanti, Maan Malahafio, Sriram Nathan, Indranee Rajapreyar, Pranav Loyalka, Biswajit Kar, Igor Gregoric

The VAD Journal

Heart failure is a serious cause of morbidity and mortality worldwide. The advent of implantable cardiac assist devices has generated a new arsenal for treating severe heart failure. However, the potential ramifications of ventricular assist device (VAD) usage are not fully understood. Immune modulation resulting from VAD implantation is an area of growing research. Although we do not fully understand the mechanisms contributing to host immune alteration, changes in cytokine concentrations, deceased lymphocyte activity, and the local effects of device materials have been shown to down regulate immune function. 7,8 Infection is a serious complication that affects prognosis in this …


Commentary On "Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment", Moises A. Huaman Aug 2015

Commentary On "Systemic Candidiasis And Cytomegalovirus Infection In The Setting Of Artificial Cardiac Device Deployment", Moises A. Huaman

The VAD Journal

No abstract provided.


Use Of Social Media As A Virtual Community And Support Group By Left Ventricular Assist Device (Lvad) Patients, Bryan Boling, Amanda Hart, Chizimuzo T.C. Okoli, Tamra Halcomb, Peggy El-Mallakh Aug 2015

Use Of Social Media As A Virtual Community And Support Group By Left Ventricular Assist Device (Lvad) Patients, Bryan Boling, Amanda Hart, Chizimuzo T.C. Okoli, Tamra Halcomb, Peggy El-Mallakh

The VAD Journal

Abstract

Background

Left ventricular assist device (LVAD) patients may benefit from participating in a social support group; however, several factors may limit the availability of these communities. Alternatively, online social support communities may be more accessible for LVAD patients. No studies have examined patterns and reasons for health-related social media use among people with LVADs

Methods

An online survey of patients actively participating in LVAD social media groups was conducted using both multiple choice and open-ended questions.

Results

Thirty-nine participants (65% male) completed the survey. Participants’ reasons for weekly engagement in online communities were to seek (69.2%) and offer (66.7%) …


Chronic Ldh Elevation After Left Ventricular Assist Device Implantation, Hesham R. Omar, Navin Rajagopalan, Maya Guglin Aug 2015

Chronic Ldh Elevation After Left Ventricular Assist Device Implantation, Hesham R. Omar, Navin Rajagopalan, Maya Guglin

The VAD Journal

A 61-year-old woman who underwent HeartMate II left ventricular assist device placement for non-ischemic cardiomyopathy developed elevated lactate dehydrogenase within two weeks after implantation. After eight months of observation and several hospital admissions during which there was no evidence of pump thrombosis, she presented with clinically manifest hemolysis. During pump exchange there was notable pannus formation on the inflow cannula of the left ventricular assist device. The pannus around the inflow likely existed for several months, limiting the flow and creating a low-grade hemolysis and this low flow state stimulated thrombus formation triggering gross hemolysis. Thoratec analysis of the pump …


Chronic Hemodialysis In A Patient With Left Ventricular Assist Device., Amr Idris, Georges Lolay, Ana L. Castellanos, Navin Rajagopalan, Maya Guglin Aug 2015

Chronic Hemodialysis In A Patient With Left Ventricular Assist Device., Amr Idris, Georges Lolay, Ana L. Castellanos, Navin Rajagopalan, Maya Guglin

The VAD Journal

Renal dysfunction in the setting of heart failure is a common medical problem. This dysfunction can range from reversible ischemic changes to renal failure requiring renal replacement therapy. Patients who are candidates for mechanical circulatory support with left ventricular assistant device (LVAD) pose unique challenge with respect to receiving dialysis. We present a 47 year old patient who required renal replacement therapy peri-implantation of LVAD for management of acute on chronic kidney disease, and was discharged for chronic hemodialysis in an outpatient setting. In this report we highlight the challenges of managing volume overload in patients with impaired renal function …


Veraflo Negative Pressure Wound Therapy With Household Bleach For Refractory Driveline Infection In A Patient With Left Ventricular Assist Device., Amr Idris, Amanda Hart, Sarah Branam, Maya Guglin Jul 2015

Veraflo Negative Pressure Wound Therapy With Household Bleach For Refractory Driveline Infection In A Patient With Left Ventricular Assist Device., Amr Idris, Amanda Hart, Sarah Branam, Maya Guglin

The VAD Journal

Driveline infections and sepsis are amongst the most common causes of morbidity and mortality in a patient with a left ventricular assist device. In this case, we present a patient with a multi drug resistant pseudomonas aeruginosa driveline exit site infection. Initially, it was treated with dual antibiotics, followed by surgical debridement utilizing Dakin’s solution irrigation and standard negative pressure wound therapy. Wound healing was minimal determined by poor granulation appearance, unchanged size from surgical debridement, purulent drainage, and the wound base remained colonized with multi drug resistant pseudomonas aeruginosa. A novel treatment of VeraFlo negative pressure wound therapy in …