Open Access. Powered by Scholars. Published by Universities.®

Medicine and Health Sciences Commons

Open Access. Powered by Scholars. Published by Universities.®

Dentistry

PDF

2017

Institution
Keyword
Publication
Publication Type

Articles 361 - 371 of 371

Full-Text Articles in Medicine and Health Sciences

Retention Of Zirconia Crowns Following Different Bonding Protocols, Suruchi Lamba Jan 2017

Retention Of Zirconia Crowns Following Different Bonding Protocols, Suruchi Lamba

All ETDs from UAB

Objective: To measure and compare the retention of zirconia crowns cemented with Ceramir (Calcium phosphate-based Bioactive Cement), RelyX Luting Plus (RMGI Cement) and RelyX Unicem (Self-adhesive resin cement) to extracted teeth following thermocycling. Methods: 30 sound extracted non-carious human molars were collected following IRB approval. The selected molars were notched at the roots and mounted into PVC molds filled with acrylic resin (Yates Motloid, USA). The occlusal surface was ground flat on a model trimmer. The axial reductions were performed with a standardized crown preparation device using a Komet 5845KR (“onlay”) diamond bur. A 10 degree ramp was used to …


Incisor Contact In Optimal Occlusion, Ryan Baker Jan 2017

Incisor Contact In Optimal Occlusion, Ryan Baker

All ETDs from UAB

The objective of the present study was to grade the overjet of untreated plaster dental study casts with optimal occlusion utilizing the American Board of Orthodontics (ABO) Objective Grading System (OGS). Currently no data set exists for incisor contact norms in optimal occlusion. Materials and Methods: 140 Plaster dental study casts possessing optimal occlusion were utilized for this study. Study casts used were obtained from the office of Dr. Lawrence F. Andrews in San Diego, CA. The majority of the study models were those used in determining Andrews Six Keys to Normal Occlusion. Overjet was graded according to the ABO …


Validation Of Mixed Dentition Analysis Method For Northern Thai Population, Wannapa Chinadet Jan 2017

Validation Of Mixed Dentition Analysis Method For Northern Thai Population, Wannapa Chinadet

All ETDs from UAB

The purpose of this study is to determine the accuracy of the Tanaka-Johnston mixed dentition analysis method and develop a new predictive model for Northern Thai population. A total of 400 sets of dental study casts (145 males and 255 females) were obtained from the Department of Pediatrics and Orthodontics at the Chiang Mai University School of Dentistry, Thailand. The models were obtained from patients that were age 11 to 23 years that consisted of a full permanent dentition. A digital caliper was used to measure the mesiodistal widths of all teeth on dental study models. The sum of the …


Retention Of Resin Composite Cam Crowns Following Different Bonding Protocols, Amir Hossein Nejat Jan 2017

Retention Of Resin Composite Cam Crowns Following Different Bonding Protocols, Amir Hossein Nejat

All ETDs from UAB

Objectives: Resin composite CAM materials offer more efficient milling, however, there is a high incidence of clinical debonding when this material is used for full-coverage crowns. The aim of the present study is to evaluate the effect of different surface treat-ments and primers on the crown retention of a new resin composite CAM material. Methods: 120 molars were prepared with a 24 degree taper, 1.5mm height, and axial walls in dentin. Surface area was measured by digital microscopy and preparations were scanned with an intraoral scanner. Crowns were milled from an experimental com-posite material with 4mm occlusal height. Teeth were …


Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr. Jan 2017

Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr.

Dentistry

Introduction: Severely atrophied mandibles are a common problem within elderly completely edentulous patients. Given their small diameters, long height and self-tapping characteristics, miniimplant retained over-dentures are a valuable treatment option in such patients. Mini-implants are usually once-piece implants, however recently two-piece mini-implants were introduced with aim of addressing the angulation problems. The success of the latter has not been thoroughly studied. Crestal bone height measurements are normally used to evaluate implant success. Therefore this study was conducted to evaluate the effect of one piece versus two piece ERA mini implants on crestal bone height of implant retained mandibular over-denture. Materials …


An In Vitro Evaluation Of Abutment Design For Anterior Zirconia Resin Bonded Restorations, Watcharapong Aroonsang Jan 2017

An In Vitro Evaluation Of Abutment Design For Anterior Zirconia Resin Bonded Restorations, Watcharapong Aroonsang

All ETDs from UAB

Resin-bonded fixed partial dentures (RBFPDs) have evolved from metal frameworks to esthetic all ceramic tooth colored restorations. However these restorations frequently fail due to a loss of retention of the retainers. As the frameworks for these restorations have changed to more esthetic ceramic materials, the search for the ideal conservative preparation design providing maximum retention is critical to improve the life span of these restorations. Purpose: This in vitro evaluation measured and compared the resistance and retention created with different abutment preparation designs with a zirconia framework. Method: 21 extracted human maxillary central incisors were divided into three groups of …


Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability, Luis Gerardo Guzman Suarez Jan 2017

Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability, Luis Gerardo Guzman Suarez

All ETDs from UAB

Objective: This study aims to investigate the correlation between the gray values (GV) of Cone Beam Computed Tomography (CBCT) analyzed by two commonly used implant planning software (coDiagnostiX, and Simplant®) and the primary stability of dental implants by measuring insertion torque value (ITV) and Resonance Frequency Analysis (ISQ). Materials and Methods: Thirty-eight patients planned to receive a total of 102 dental implants (Straumann Bone Level Tapered) were enrolled in the study. At time of implant placement, ITV in Ncm with a Bien-Air iChiropro implant console, resonance frequency analysis (ISQ) with an Osstell device, and the surgeon’s estimated torque of placement …


The Effect Of Temperature On Different Resin Cements Used For Cementing A Milled Titanium Bar, Firas Mourad Jan 2017

The Effect Of Temperature On Different Resin Cements Used For Cementing A Milled Titanium Bar, Firas Mourad

All ETDs from UAB

Purpose: To investigate the effect of acrylic processing on push-out strength of Ti copings luted to Milled Ti frameworks using differing resin cements. Materials and Methods: The experimental design consisted of three groups of 30 specimens each. Three different luting cements were utilized (One for each group), Panavia V5 Dual Cure Kuraray, Multilink Dual Cure Hybrid Ivoclar-Vivadent, and RelyX Unicem-2 self-adhesive 3M. The experimental model consists of trans-mucosal Titanium Coping, Abutment analog, Milled Ti hollow cylinder (9.0mm-OD) represents the milled Ti bar. The Abutment copings were luted to milled-Ti cylinders using the 3 dental cements and an alignment jig to …


Volumetric Analysis Of The Lips In Aging African American And Caucasian Males, Matthew Steven Leftwich Jan 2017

Volumetric Analysis Of The Lips In Aging African American And Caucasian Males, Matthew Steven Leftwich

All ETDs from UAB

VOLUMETRIC ANALYSIS OF THE LIPS IN AGING AFRICAN AMERICAN AND CAUCASIAN MALES DEPARTMENT OF ORTHODONTICS ABSTRACT The purpose of this cross sectional study was to analyze the volumetric changes in lip volume with respect to aging in a population of African American and Caucasian males using three-dimensional imaging technology. Materials and Methods: A sample size of 102 Caucasian males and 90 African American males with balanced faces divided into five age groups distributed as follows:[20-30], [31-40], [41-50], [51-60], [61-70[.Three-dimensional images were obtained using the 3dMDfaceTM camera system. The subjects were placed in front of the camera in natural head position …


Osteoblast And Chondrocyte Specific Contribution Of The Runx2 Gene During The Development Of Cleidocranial Dysplasisa, Kayla Renee King Jan 2017

Osteoblast And Chondrocyte Specific Contribution Of The Runx2 Gene During The Development Of Cleidocranial Dysplasisa, Kayla Renee King

All ETDs from UAB

The Runx2 transcription factor is essential for the differentiation of mesenchymal stem cells into functional chondrocytes and osteoblasts. In humans, the haploinsufficiency of the Runx2 gene is associated with cleidocranial dysplasia (CCD). The CCD is characterized by short stature, open sutures and fontanels in the skull, hypoplastic clavicles and supernumerary teeth. Skeletal elements disrupted in CCD patients are developed by intramembranous and/or endochondral ossification. However, the cell type specific roles of the Runx2 gene in the development of CCD-associated skeletal defects remain unknown. The main goal of this research was to define the specific role of the Runx2 gene in …


Tight End Rankings, Bram Nealon Dec 2016

Tight End Rankings, Bram Nealon

Bram Nealon

my professional opinion on bringing back NFL players to Purdue for the Black-Out only
1 game contract
Take it out of the players' salaries
Remember that time Purdue QBs started for both LSU and Florida? That was weird
We should bring that bacc
This is my personal rankings for whom I would like to recruit for the Black-Out

Also Jimmer Fredette, boi dat man thicc