Full-Text Articles in Life Sciences
Increased Birth Weight Is Associated With Altered Gene Expression In Neonatal Foreskin, Leryn J. Reynolds, Rebecca I. Pollack, Richard J. Charnigo, Cetewayo S. Rashid, Arnold J. Stromberg, Shu Shen, John O'Brien, Kevin J. Pearson
Increased Birth Weight Is Associated With Altered Gene Expression In Neonatal Foreskin, Leryn J. Reynolds, Rebecca I. Pollack, Richard J. Charnigo, Cetewayo S. Rashid, Arnold J. Stromberg, Shu Shen, John O'Brien, Kevin J. Pearson
Pharmacology and Nutritional Sciences Faculty Publications
Elevated birth weight is linked to glucose intolerance and obesity health-related complications later in life. No studies have examined if infant birth weight is associated with gene expression markers of obesity and inflammation in a tissue that comes directly from the infant following birth. We evaluated the association between birth weight and gene expression on fetal programming of obesity. Foreskin samples were collected following circumcision, and gene expression analyzed comparing the 15% greatest birth weight infants (n = 7) v. the remainder of the cohort (n = 40). Multivariate linear regression models were fit to relate expression levels on differentially …
Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt
Using A Respiratory Navigator Significantly Reduces Variability When Quantifying Left Ventricular Torsion With Cardiovascular Magnetic Resonance, Sean M. Hamlet, Christopher M. Haggerty, Jonathan D. Suever, Gregory J. Wehner, Kristin N. Andres, David K. Powell, Richard J. Charnigo, Brandon K. Fornwalt
Electrical and Computer Engineering Faculty Publications
Background: Left ventricular (LV) torsion is an important indicator of cardiac function that is limited by high inter-test variability (50% of the mean value). We hypothesized that this high inter-test variability is partly due to inconsistent breath-hold positions during serial image acquisitions, which could be significantly improved by using a respiratory navigator for cardiovascular magnetic resonance (CMR) based quantification of LV torsion.
Methods: We assessed respiratory-related variability in measured LV torsion with two distinct experimental protocols. First, 17 volunteers were recruited for CMR with cine displacement encoding with stimulated echoes (DENSE) in which a respiratory navigator was used to measure …