Open Access. Powered by Scholars. Published by Universities.®

Other Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 30 of 64

Full-Text Articles in Other Engineering

Fire Protection And Life Safety Analysis Report, Ayoung Yun Jun 2025

Fire Protection And Life Safety Analysis Report, Ayoung Yun

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the fire and life safety performance of the proposed building, a two- story, mixed-occupancy facility designed to serve as a civic and cultural hub. The analysis was prepared to assess compliance with the 2021 International Building Code (IBC), NFPA 13, NFPA 72, and related standards, with a particular focus on areas where occupant egress paths challenge prescriptive limitations. The project includes assembly, business, and storage occupancies, and features a large auditorium, classrooms, an exhibition hall, a restaurant, offices, and a double-height atrium. The building is designed as a non-separated mixed-use facility and is classified under Groups A-1, …


Fire Protection And Life Safety Analysis Report California State University Of Dominguez Hills, Jung Sub Kim Jun 2024

Fire Protection And Life Safety Analysis Report California State University Of Dominguez Hills, Jung Sub Kim

Fire Protection Engineering: Culminating Experience Project Reports

This report provides detailed fire and life safety analysis of the California State University of Dominguez Hills, Innovation and Instruction Building. The building is 4 stories high, accommodating an auditorium, classrooms, labs, and office spaces. Type of construction for the building is II-A. The building will have an aggregate floor area of 83,539 square feet of across four floors.

First half of the report includes prescriptive fire and life safety analysis conducted in accordance with 2021 Edition International Building Code and the applicable Standards, such as National Fire Protection Association (NFPA) 13, Standard for the Installation of Sprinkler Systems, 2022 …


Project Buildings, Anthony Pamintuan Jun 2024

Project Buildings, Anthony Pamintuan

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the prescriptive based design of a government-use high-rise building whose primary use is a business office building in California utilizing the California Building Code 2022 Edition. For security purposes, the name of the project will be the “Project Building.” The project site consists of a common podium underground parking garage with two high-rise buildings and an auditorium built on the parking garage. The project buildings that were analyzed consisted of the underground parking garage, the auditorium, and one of the high-rise buildings.

The parking garage is approximately 135,000 square feet consisting of mixed occupancies throughout. The mixed …


Training Facility, Andrew Kuharski Jun 2024

Training Facility, Andrew Kuharski

Fire Protection Engineering: Culminating Experience Project Reports

The Training Facility is a two-story, 142,500 sq. ft. building constructed in 1994 at the Savannah River Site DOE complex. The facility primarily contains training rooms, office space, and a cafeteria. Fire protection features of the Training Facility are detailed in this report, including key life safety, suppression, alarm, and structural features. The building has several deficiencies; the second floor has an occupant load of 911 occupants but is only provided with an exit capacity of 800, and occupancy size per floor exceeds what is allowed for assembly occupancies on the first floor. The travel distance from the records storage …


Two-Story Dod Office Building, Jacob Ost Jun 2024

Two-Story Dod Office Building, Jacob Ost

Fire Protection Engineering: Culminating Experience Project Reports

This report is a comprehensive analysis of the fire protection and life safety components for an administrative office building designed for the Department of Defense. The owner of the facility has requested that all identifying information, including name and location, not be included in this report and has since been removed from the documents.

The building was designed in 2019 and is currently under construction. The building is two stories with a total area of approximately 125,000 square feet. The building is primarily used as office space for administrative personnel and consists of open and single-user office space, conference rooms, …


University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide Jun 2023

University Of Washington Bill & Melinda Gates Center For Computer Science & Engineering, Devin Ide

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze and evaluate the prescriptive and performance-based criteria used to design the fire protection systems installed in the Gates Center for Computer Science and Engineering at the University of Washington, Seattle Campus. The Gates Center is a five-story building housing business and assembly spaces such as classrooms, workrooms, offices, a lecture hall, event center, and a café. The main architectural feature is a central atrium, which connects the ground, first, second, and third floors of the building.

Aspects of the prescriptive-based fire protection design include egress, automatic sprinkler systems, detection and notification devices, …


Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo Jun 2023

Design Fire Robert E. Kennedy Library, California Polytechnic State, San Luis Obispo, Jennifer Ocampo

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the fire protection system of the Kennedy Building using a prescriptive approach and a performance-based design. The prescriptive approach evaluates code compliance of the structural design, fire suppression system, alarm and detection and smoke control. The performance-based design evaluates egress and life safety protection and three design fires that could potentially compromise the goals and objectives of the design.

The Kennedy Building is on the Campus of Cal Poly, San Luis Obispo and serves as the primary library of the university. This building has five stories of mixed occupancies. It is partially sprinklered, has limited automatic detection …


Office Building In Moffett Park District, Cody Williams Jun 2023

Office Building In Moffett Park District, Cody Williams

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this review is to analyze and evaluate the fire safety of a 5-story office building located in the Moffett Park District in Sunnyvale, California. The building is constructed largely of mass timber and classified as a Type IIIA building used primarily as office space. The first section of the report focuses on the building’s defining characteristics and use cases. The second portion of the report presents a comprehensive review of egress design, fire alarm systems, fire suppression systems, structural design, implementation of mass timber elements, and flammability requirements. The results of the analysis show that the building …


Fire Life Safety Design Of Technology Office, Jared Ellis Mar 2023

Fire Life Safety Design Of Technology Office, Jared Ellis

Fire Protection Engineering: Culminating Experience Project Reports

The subject building is an approximately 180,000 SF technology office; the location and some details are omitted for privacy of the project and client. It is a 3-story heavy timber frame (Type IIIA) over 1 level of concrete basement stepped into a hillside.

The building is compliant with the prescriptive building code for egress, fire alarm, and fire sprinkler systems. A NFPA 72 compliant fire detection, notification and communication system is provided. The building is fully sprinklered with a system that is hydraulically designed per NFPA 13, 2016 Section 11.2.3 Water Demand Requirements – Hydraulic Calculation Methods. Water supply is …


Process Support Building Savannah River Site, Victoria Zawacki Jun 2022

Process Support Building Savannah River Site, Victoria Zawacki

Fire Protection Engineering: Culminating Experience Project Reports

A report on the fire and life safety analysis of the Savannah River Site Process Support Building is required in order to receive a Master of Science in Fire Protection Engineering from the California Polytechnic State University, San Luis Obispo. The Process Support Building is a two-story office building that was first occupied in 2013, with a floor area of approximately 10,000 ft2. The building contains mainly personal offices, but also contains conference and turnover rooms, a Computer Simulation Room, an Observation Room, and a lunch area. The analysis includes both prescriptive and performance-based analysis.

The Process Support Building is …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt Jun 2022

Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt

Fire Protection Engineering: Culminating Experience Project Reports

This report covers an analysis of the fire protection features within the Warren Baker Center for Science and Mathematics Building. This document first discusses the prescriptive requirements for the building as determined by applicable code. The items to be discussed, as they relate to prescriptive requirements, include the means of egress and relatable components, fire resistive construction, fire alarm system, fire sprinkler system, and smoke control system. All components were analyzed and compared to each applicable code to assess whether these specific fire protection systems were designed correctly.

In addition to an analysis of the prescriptive measures in this facility, …


Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft Jun 2022

Mount Sac Gym & Aquatics Center: Fire & Life Safety Report, Alex Hoeft

Fire Protection Engineering: Culminating Experience Project Reports

This report has been prepared to review and analyze the Fire and Life Safety status of the proposed Gym & Aquatics building at Mt. San Antonio College. This was done using two methods: prescriptive and performance based. The prescriptive section examines the explicitly code-mandated requirements for the building and the performance-based section examines implicit requirements for the building based on the goals presented in the Life Safety Code, NFPA 101.

The subject building is a 147,000 square foot, two-story, steel-framed athletics complex occupied primarily for assembly and business uses. The structure has an indoor and outdoor component with two gymnasiums …


Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long Jun 2022

Fire Safety Management Plan For South Texas Project Turbine Generator Building, Brett Long

Fire Protection Engineering: Culminating Experience Project Reports

This report includes a fire protection and life safety analysis of the South Texas Project Turbine Generator Building (TGB). This analysis was done to fulfill the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The Turbine Generator Building consists of three elevations and is Type II-B construction. The TGB’s primary use is a special-purpose industrial building housing the turbine generator, main feed pumps, condensate pumps, condenser, feed water re-heaters, secondary cold chemistry lab, Balance-of-Plant (BOP) diesel, batteries, and switchgear, 13.8 kVA switchgear, and various other systems and components. This analysis consists of …


B-91 Fire Protection Analysis, Evan Phillips Jun 2021

B-91 Fire Protection Analysis, Evan Phillips

Fire Protection Engineering: Culminating Experience Project Reports

B-91 is a multiuse building on a Department of Defense installation rented out to a defense contractor consisting of laboratory, office, storage, and utility spaces. To determine the adequacy of the building’s fire protection systems as determined by the state-adopted 2015 International Building Code, a prescriptive analysis was performed with specific areas of focus on the building construction and occupancy, emergency egress capacity, fire suppression systems, and fire alarm systems. The building is compliant with code requirements in its construction and the fire alarm systems are adequately designed to provide notice, but the egress from the building’s main conference room …


Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck Jun 2021

Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzed several different aspects of the fire protection and life safety strategy for the Tritium Engineering Building (TEB) at the Savannah River Site in Aiken, SC. The TEB is a single-story, Type IIB building that primarily houses engineering and technical staff. The building is approximately 15,560 ft2 and consists of two large “open areas” enclosed by hard- wall offices. Modular workstations are located in both “open areas” and accommodate the majority of the building occupants. This analysis provided both a prescriptive and a performance-based approach for analyzing fire hazards within the building. The prescriptive- based analysis evaluated the …


College Sports Center Fire Protection Analysis, Elijah Kimmig Jun 2021

College Sports Center Fire Protection Analysis, Elijah Kimmig

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this project was to analyze and compare the existing fire protection systems in the college sports center to current applicable codes and standards. Both prescriptive based analysis and performance based analyses were performed.

The prescriptive based analyses included analyzing the structural fire protection, fire suppression, fire alarm, and egress systems. Overall, the majority of the fire protection systems appeared to meet the requirements of the current codes but there are a few items that were found that appear to not meet current code. These items are listed below along with recommendations to mitigate: (1) Placement of certain …


Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll Jun 2021

Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll

Fire Protection Engineering: Culminating Experience Project Reports

This project report contains a fire and life safety analysis of the Johnson Controls Office Building. The building is located in Los Angeles, California. The building is a mixed use occupancy with office spaces, meeting rooms, training rooms, and a warehouse for storing fire sprinkler and fire alarm materials. The building is one level with a mezzanine. It is attached to another building and separated by fire barrier so that they are considered separate buildings. This report contains a prescriptive analysis and a performance-based design analysis of the building.

The prescriptive code requirements were determined based on the 2019 edition …


Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag Jun 2021

Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag

Fire Protection Engineering: Culminating Experience Project Reports

The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …


California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff Jun 2021

California Polytechnic State University – San Luis Obispo Building 180: Baker, Kelly Kessloff

Fire Protection Engineering: Culminating Experience Project Reports

This project was performed as part of the requirements for completion of the Fire Protection Engineering Master’s Program at Cal Poly. This project covers a full prescriptive and performance based analysis on the Warren J. Baker Center for Science and Mathematics. This building was constructed on Cal Poly’s campus in 2013 and serves occupancies such as classrooms, laboratories, and office space for students and professors.

The prescriptive based analysis of this report will analyze the applicable building codes and determine if this building is compliant. Relevant codes include the 2016 California Building and the 2016 California Fire Code. In addition …


Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton Jun 2020

Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton

Fire Protection Engineering: Culminating Experience Project Reports

The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.

The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …


Powell Building, David John Devinney Jun 2020

Powell Building, David John Devinney

Fire Protection Engineering: Culminating Experience Project Reports

A detailed study of the fire and life safety systems was performed on the Powell Building located in Oak Ridge, TN. This report consists of both prescriptive and performance-based analysis. The prescriptive based analysis reviews the fire and life safety requirements in accordance with the applicable codes. The prescriptive portion of this report included life safety, fire suppression systems, fire alarm and detection systems, and structural fire protection. The performance-based analysis was used with viable fire scenarios to ensure that occupants could safely egress the building. This was accomplished by comparing the Required Safe Egress Time (RSET) with the Available …


Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura Jun 2020

Culminating Course Progress Report For The Na893 Community Support Center, Yokosuka Naval Base, Japan, Kazuo Miura

Fire Protection Engineering: Culminating Experience Project Reports

This is the culminating project report for the Fire Project Engineering Master’s of Science at California Polytechnic at San Luis Obispo. This project will consider a project for the US military in Japan, JFY893 Community Support Facility, Yokosuka Naval Base. The subject facility consists of a library, education center, family services, and other community services. The Library shall serve as the Main Base Library, keep and store books and provide library services for active duty population, dependents and retirees. The Education Center provides services for advancing of the academic, technical, and vocational education of military personnel of all grades and …


New Stanford Hospital, Fpe 2020 Student Mar 2020

New Stanford Hospital, Fpe 2020 Student

Fire Protection Engineering: Culminating Experience Project Reports

This report is the compiled culminating project for the Fire Protection Engineering Master’s Program at Cal Poly, SLO. Addressed herein is the fire protection and life safety approach for the New Stanford Hospital in Palo Alto, California in accordance with the 2012 NFPA 101 – Life Safety Code and the 2016 California Building and Fire Codes. This includes review of building occupancies, construction type, fire-resistive ratings, means of egress, and fire protection systems. The objective of this report is to review the impact of major fire scenarios on life, property, and operations.

The New Stanford Hospital is a Type IA …


Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson Jun 2019

Cal Poly State University Robert E. Kennedy Library Fire Protection Analysis Report, Timothy Anderson

Fire Protection Engineering: Culminating Experience Project Reports

This report determines whether or not the fire protection and life safety features of Robert E. Kennedy Library are consistent with the fire protection objectives established in nationally recognized fire protection codes and standards. This analysis is performed to establish a technical baseline for identification of fire protection deficiencies.

Kennedy Library is the campus student library at California Polytechnic State University. The facility provides resources and services in a variety of media to meet the needs of university students and faculty.

This analysis consists of a prescriptive analysis and a performance-based analysis. The prescriptive analysis is an analysis of the …


Atx Storage: Fire And Life Safety Analysis, Perla Salcedo Jun 2019

Atx Storage: Fire And Life Safety Analysis, Perla Salcedo

Fire Protection Engineering: Culminating Experience Project Reports

The following report is a fire and hazard protection analysis of a new building. This new building is a self-storage building called ATX Storage locate in Austin, TX. The prescriptive requirements set by the codes and standards used at time of construction of the building have been met. The building has been properly classified with respect to occupancy as S1, Group B and R-3 and construction type II A Sprinklered. Appropriate design for interior partitions and exterior wall have been identified. Interior finish requirements have been analyzed for a better understanding of aesthetics guidelines. Based on the sprinkler drawing calculations, …


Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline Jun 2018

Prescriptive And Performance Analysis Of Cold Machine Shop, John Kline

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze the fire and life safety aspects of the Cold Machine Shop located on the central coast of California. This report includes both a prescriptive and performance based analysis.

The prescriptive analysis will evaluate the building as follows, to ensure compliance with standard codes: 1)Egress analysis and design using NFPA 101, "Life Safety Code", 2)Fire detection, alarms, and communication systems using NFPA 72, "National Fire Alarm and Signaling Code", 3)Water-based fire suppression systems using NFPA 13, " Standard for Installation of Sprinkler Systems" and NFPA 14, " Standard for the Installation of Standpipe …


An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan Jun 2018

An Analysis Of The Life Safety And Fire Protection Features Of A New Hotel On California’S Central Coast, James Henahan

Fire Protection Engineering: Culminating Experience Project Reports

This report examines the fire protection and life safety features of a new, 3-story plus basement, hotel on California’s Central Coast. These features are examined from both a prescriptive, code-driven perspective, as well as from a performance-based design point of view.

The prescriptive analysis includes exit configuration and capacity, the NFPA 13 sprinkler system, the NFPA 72 fire alarm system, and the building construction types. All were found to be acceptable when compared against the applicable codes the building is subject to, with the exception of some of the load- bearing exterior walls.

The performance-based component examines the affect two …


Shyh Wang Hall- Lbnl Building 59, Mike Torkelson Jun 2018

Shyh Wang Hall- Lbnl Building 59, Mike Torkelson

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of Shyh Wang Hall, a new building at the Lawrence Berkeley National Laboratory. Wang Hall houses offices, high performance computers, and associated mechanical space. The building is constructed as a Type IIB structure and includes four stories. Both prescriptive-based and performance-based design is considered.

The prescriptive analysis considers the fire and life safety features as required by applicable codes, including the Department of Energy requirements. The building is protected by fire detection and alarm system as well as automatic sprinklers. The prescriptive design meets the code requirements with the possible exception …


Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman Mar 2018

Fire And Life Safety Analysis- College Campus Building, Jacob Ludeman

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis was performed as an academic exercise as part of the MS Fire Protection Engineering Program of California Polytechnic State University, San Luis Obispo. The project is a culminating report with regards to prescriptive based and performance based aspects for the fire and life safety analysis of a project building. These analyses were performed on a building located on a college campus in Southern California and is to remain nameless upon the request of the owner and architect. The building is in the School of Physical Sciences at the University it resides. The building houses …