Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2011

California Polytechnic State University, San Luis Obispo

Pump

Articles 1 - 3 of 3

Full-Text Articles in Engineering

Characteristics Of Irrigation Pump Performance In Major Irrigated Areas Of California, Charles Burt May 2011

Characteristics Of Irrigation Pump Performance In Major Irrigated Areas Of California, Charles Burt

BioResource and Agricultural Engineering

Pumping data was collected from over 15,000 well and non-well pumps throughout the Sacramento, Salinas, and San Joaquin Valley groundwater basins of California. Each of these basins is divided into a number of subbasins. A map of the general layout is shown below (gray lines outside of basins represent county lines; gray lines inside basins represent subbasins).

Data was analyzed by basin and subbasin for well pumps and non-well pumps. For each pump type, averages were calculated based on:

  • The whole basin
  • Overall pumping plant efficiency (OPPE)
  • kWh/AF
  • Subbasins

General conclusions were drawn for each set of averages, and a …


Variable Frequency Drive (Vfd) Controlled Irrigation Pumps – Analysis Of Potential Rebate, Charles M. Burt Jan 2011

Variable Frequency Drive (Vfd) Controlled Irrigation Pumps – Analysis Of Potential Rebate, Charles M. Burt

BioResource and Agricultural Engineering

Well pumps, booster pumps, and a combination of the two are used throughout the agricultural sector to provide water for on-farm irrigation. However, the pump discharge pressures for the majority of irrigation systems are excessive, waiving considerable monetary and power consumption savings. This report analyzes the numerous potential benefits of integrating a variable frequency drive (VFD) to irrigation supply systems and modifying system design philosophies.


Characteristics Of Pump Performance In Major Irrigated Areas Of California, Sierra A. Orivs, Charles M. Burt, Luis P. Urrestarazu Jan 2011

Characteristics Of Pump Performance In Major Irrigated Areas Of California, Sierra A. Orivs, Charles M. Burt, Luis P. Urrestarazu

BioResource and Agricultural Engineering

Well pump tests (12,876) in three Central California groundwater basins were characterized and described according to their spatial distribution. The average overall pumping plant efficiency (wire-water, not including column losses and velocity head) was about 56%. Characteristics such as drawdown, total dynamic heads, kW, and flow rate vary greatly between pumps within and between sub-basins. This is the first well pump characterization of its type in California, although irrigation pump tests have been conducted for over 70 years in California. This paper provides a summary of the spatial variation of well pump performance and characteristics.