Dissolution testing

Publication Year

Articles 1 - 6 of 6

Full-Text Articles in Engineering

Experimental Determination Of The Agitation Requirements For Solids Suspension In Dissolution Systems Using A Mini Paddle Apparatus, Yang Song May 2015

Experimental Determination Of The Agitation Requirements For Solids Suspension In Dissolution Systems Using A Mini Paddle Apparatus, Yang Song

Theses

Dissolution testing is a critical step in quality control of manufactured final products in the pharmaceutical industry. The United State Pharmacopeia (USP) Dissolution Testing Apparatus 2 (paddle) is the most widely used dissolution test devices in the pharmaceutical industry to formulate solid drug dosage forms and to develop quality control specifications for its manufacturing process.

Mini vessels and mini paddle dissolution testing systems are smaller versions of the USP 2 Apparatus. The concept of the mini paddle apparatus is similar to that of the USP 2 setup but it is scaled down about to 1/5 of the volume and 40% …


Hydrodynamic Effects Of A Cannula In A Usp Dissolution Testing Apparatus 2, Qianqian Liu May 2013

Hydrodynamic Effects Of A Cannula In A Usp Dissolution Testing Apparatus 2, Qianqian Liu

Theses

Dissolution testing is routinely used in the pharmaceutical industry to provide in vitro drug release information for drug development and quality control purposes. The USP Testing Apparatus 2 is the most common dissolution testing system for solid dosage forms. Usually, sampling cannulas are used to take samples manually from the dissolution medium. However, the inserted cannula can alter the normal fluid flow within the vessel and produce different dissolution testing results.

The hydrodynamic effects introduced by a permanently inserted cannula in a USP Dissolution Testing Apparatus 2 were evaluated by two approaches. Firstly, the dissolution tests were conducted with two …


Effect Of Tablet Compression On The Dissolution Of Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Chuan Sun May 2013

Effect Of Tablet Compression On The Dissolution Of Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Chuan Sun

Theses

In the pharmaceutical industry, dissolution testing is routinely carried out to determine the dissolution rate of oral solid dosage forms. Among several testing devices, the USP Dissolution Apparatus 2 is the device most commonly used. However, despite its widespread use, this apparatus has been shown to produce test failures and to be very sensitive to a number of small geometry changes.

The objective of this study was to determine whether a novel dissolution system termed “OPI” for “off-center paddle impeller” was sensitive enough to determine differences in tablet dissolution profiles caused by different compression pressure during the tablet manufacturing process. …


Dissolution Of Different Commercial Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Yang Qu May 2013

Dissolution Of Different Commercial Aspirin Tablets Using A Novel Off-Center Paddle Impeller (Opi) Dissolution Testing System, Yang Qu

Theses

Dissolution testing is routinely conducted in the pharmaceutical industry to provide in vitro drug release information for quality control purposes. The most common dissolution testing system for solid dosage forms is the United States Pharmacopeia (USP) Dissolution Testing Apparatus 2. In this work, a modified Apparatus 2, termed "OPI" System for "off-center paddle impeller," in which the impeller is placed 8 mm off center in the vessel is tested to determine its sensitivity to differentiate between the dissolution profiles of differently formulated and manufactured tablets. Dissolution tests are conducted with both the OPI System and the Standard System using three …


Hydrodynamic Effects Of An Arch-Shaped Fiber Optic Probe In A Dissolution Testing Apparatus 2, Yiran Zhang May 2012

Hydrodynamic Effects Of An Arch-Shaped Fiber Optic Probe In A Dissolution Testing Apparatus 2, Yiran Zhang

Theses

Dissolution testing is widely used in the pharmaceutical industry to evaluate newly developed drug formulations and as a quality control method to insure that solid dosage forms have consistent dissolution property. Typically, samples are manually drawn from the dissolution vessel prior to analysis. An approach to overcome the limitations of manual sampling consists in the use of sampling probes, such as fiber optic probes, permanently inserted in the dissolution medium and continually sampling the drug concentration in it as the solid dosage form dissolves. Despite their advantages, permanently inserted fiber optic probes can alter the normal fluid flow within the …


Dissolution Testing Of Prednisone And Salicylic Acid Calibrator Tablets At Different Tablet Locations, Anandhavalavan Arulmozhi May 2011

Dissolution Testing Of Prednisone And Salicylic Acid Calibrator Tablets At Different Tablet Locations, Anandhavalavan Arulmozhi

Theses

Dissolution testing is routinely carried out in the pharmaceutical industry to determine the rate of dissolution of solid dosage forms. This test is one of the several tests that pharmaceutical companies typically conduct on oral dosage formulations (e.g., tablets) to determine compliance. The USP Dissolution Testing Apparatus 2 is the most common of the apparatuses listed in the USP. However, it has been shown previously that the dissolution profile of a tablet undergoing dissolution in the USP Dissolution Apparatus 2 can be affected by the tablet location in the apparatus.

In this work, the dissolution rates of both non-disintegrating tablets …