Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Series

PDF

Mechanical Engineering

Ducts

2019

Articles 1 - 1 of 1

Full-Text Articles in Engineering

Residential Attic Performance Comparison Research, Florida Solar Energy Center, Charles Withers, Jr. Jun 2019

Residential Attic Performance Comparison Research, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

This research project evaluated cooling energy and moisture-related impacts between conventional attic venting and sealed attic vents in a lab home located in central Florida. All tests had R30 insulation on the ceiling and the roof deck uninsulated. A total of four different test configurations were tested. The four tested configurations were: Attic Vented with Attic Ducts, Attic Vents Sealed with Attic Ducts, Attic Vented with Indoor Ducts, and Attic Vents Sealed with Indoor Ducts. On average the impact from sealing attic vents will increase annual cooling energy use in a Florida home between 5%-10%. For a 1620 square foot …