Full-Text Articles in Engineering

Measured And Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction, Florida Solar Energy Center, David Chasar Aug 2002

Measured And Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction, Florida Solar Energy Center, David Chasar

FSEC Energy Research Center®

Four occupied homes near Dallas, Texas were monitored to compare cooling energy use. Two homes were built with typical wood frame construction, the other two with insulated concrete form (ICF) construction. Remote data loggers collected hourly readings of indoor and outdoor temperature, relative humidity, furnace runtime fraction, total building electrical energy and HVAC energy use. Data was recorded from January through August 2000.

Analysis of the measured data shows that insulated concrete form (ICF) construction can reduce seasonal cooling energy use 17 - 19% over frame construction in two-story homes in the North Texas climate. This result includes adjustments to …


Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine Jul 2002

Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine

FSEC Energy Research Center®

To combat the energy, durability, and indoor air quality penalties of duct leakage, energy experts have recommended putting the duct system and air handler inside the conditioned space. Two paths of accomplishing this have emerged: unvented attics/crawl spaces and interior chases. This study focuses on the design, construction, and performance of the interior chase approach as implemented by five different builders in Texas, North Carolina, and Florida.

Researchers found that, in many cases, breeches of the air barrier were evident from simple visual inspection. Critical points of design and construction were identified and will be presented through photos, design and …


Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr. May 2002

Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Two nearly identical houses situated next to each other in Bossier City, Louisiana were studied in an effort to better understand moisture and cooling energy related problems in manufactured houses with low thermostat set-points during the cooling season. By design, the major difference between houses was the type of air conditioning units. House A had a standard split air conditioner and House B had a two-speed split air conditioner.

In an effort to make the buildings more similar, the building airtightness was adjusted until it was the same in each house, and duct leaks were sealed so that the ducts …