Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Engineering

Estimations Of Ammonia And Hydrogen Sulfide Fluxes From Cattle Feedlot Surfaces In Texas High Plains, Bok-Haeng Baek, Jacek A. Koziel, Jarett P. Spinhirne, David B. Parker, Nolan A. Cole Oct 2003

Estimations Of Ammonia And Hydrogen Sulfide Fluxes From Cattle Feedlot Surfaces In Texas High Plains, Bok-Haeng Baek, Jacek A. Koziel, Jarett P. Spinhirne, David B. Parker, Nolan A. Cole

Jacek A. Koziel

A dynamic flow-through chamber system and continuous analyzers were used for on-site measurements of ammonia-nitrogen (NH 3 -N) and hydrogen sulfide-sulfur (H 2 S-S) fluxes from commercial feedlot surfaces in northwestern Texas during two week period in the summer of 2002. Ambient air and air inside chamber temperatures, and manure pack temperature were measured continuously. Manure pack moisture content, pH, and TKN were measured daily to characterize its correlation with NH 3 -N fluxes. The preliminary average NH 3 -N flux from the feedlot surface for the entire measurement period was 1,669 ± 1,212 NH 3 -N µ g/m 2 …


Generation And Calibration Of Standard Gas Mixtures For Volatile Fatty Acids Using Permeation Tubes And Solid Phase Microextraction, Jacek A. Koziel, Jarett P. Spinhirne Oct 2003

Generation And Calibration Of Standard Gas Mixtures For Volatile Fatty Acids Using Permeation Tubes And Solid Phase Microextraction, Jacek A. Koziel, Jarett P. Spinhirne

Jacek A. Koziel

Volatile fatty acids (VFAs) are major components of odors associated with agricultural operations and livestock housing, solid waste processing and disposal, and industrial and municipal wastewater collection and treatment systems. Emissions estimation and assessment of odor control methods depend on reliable air sampling and analysis methods for VFAs. The objective of this research was to develop and test a method for continuous and reliable generation of standard gas mixtures for VFAs based on permeation tubes. Standard gas mixtures for acetic, propionic, isobutyric, butyric, isovaleric, valeric, and hexanoic acids were generated with permeation tubes and monitored for a 100-day period. The …


Assessment Of Moisture Control And Additives For Odor Reduction From Open-Lot Feedyard Surfaces, Jocelyn D. Buchanan, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, William J. Rogers Jul 2003

Assessment Of Moisture Control And Additives For Odor Reduction From Open-Lot Feedyard Surfaces, Jocelyn D. Buchanan, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, William J. Rogers

Jacek A. Koziel

Amendments for reducing odor from open-lot beef cattle feedyards were evaluated in the laboratory. Manure was placed in small Tupperware® containers. Water and amendments were added to the manure surface and the containers were attached to a vacuum pump that continually passed 2.5 L/min of carbon-filtered air over the surface. Eleven different amendments were tested, at two different concentrations, in a series of five experiments. Odor samples were collected 3 times during a 10-day period in each experiment and were analyzed by trained panelists for detection threshold (DT), intensity and hedonic tone. None of the amendments showed any overwhelming evidence …


Background Odors In Tedlar® Bags Used For Cafo Odor Sampling, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, Jarett Spinhirne Jul 2003

Background Odors In Tedlar® Bags Used For Cafo Odor Sampling, David B. Parker, Marty B. Rhoades, Jacek A. Koziel, Jarett Spinhirne

Jacek A. Koziel

Tedlar® film is manufactured in a wet solvent process and continues to emit organic compounds after manufacturing. Tedlar® bags are used for odor sampling at concentrated animal feeding operations (CAFOs). Odor regulations for CAFOs vary widely, but maximum detection thresholds (DTs) of 2 to 15 have been proposed downwind of feeding operations. Results at the WTAMU Olfactometry Laboratory have shown that both commercially available Tedlar® bags and homemade Tedlar® bags have a detectable background odor (DTs of 20 to 60 typical) even following standard protocols for purging. Purging the bags before sampling was not effective in reducing DTs to acceptable …


Estimation Of Ammonia And Hydrogen Sulfide Emissions From Cattle Feedlots In Texas, Bok-Haeng Baek, Jacek A. Koziel, Jarett P. Spinhirne, David B. Parker, Nolan A. Cole Jul 2003

Estimation Of Ammonia And Hydrogen Sulfide Emissions From Cattle Feedlots In Texas, Bok-Haeng Baek, Jacek A. Koziel, Jarett P. Spinhirne, David B. Parker, Nolan A. Cole

Jacek A. Koziel

A dynamic flow-through chamber system and continuous analyzers were used for on-site measurements of ammonia-nitrogen (NH 3 -N) and hydrogen sulfide-sulfur (H 2 S-S) fluxes from commercial feedlot surfaces in northwestern Texas during two week period in the summer of 2002. Manure pack moisture content, pH, and TKN were measured daily to characterize its relation with NH 3 -N fluxes. The preliminary average NH 3 -N and H 2 S-S flux from the feedlot surface were 1,669 ± 1,212 NH 3 -N µ g/m 2 /min and 1.884 ± 1.497 H 2 S-S µ g S/m 2 /min. Manure pack …


Odor Characterization At Open-Lot Beef Cattle Feedyards Using Triangular Forced Choice Olfactometry, David B. Parker, Marty B. Rhoades, Brent W. Auvermann, Jacek A. Koziel Jul 2003

Odor Characterization At Open-Lot Beef Cattle Feedyards Using Triangular Forced Choice Olfactometry, David B. Parker, Marty B. Rhoades, Brent W. Auvermann, Jacek A. Koziel

Jacek A. Koziel

Odor samples were collected two to four times per month over a one-year period in 2002-2003 at three large open-lot beef cattle feedyards in the Texas panhandle. Samples were collected in 10 L Tedlar bags using a vacuum chamber upwind of the feedyard, downwind of the pens, and downwind of the runoff storage pond. Samples were analyzed in the odor lab for detection threshold (DT) using triangular forced choice olfactometry with trained human odor panelists. Full-strength odor samples were also analyzed for intensity and hedonic tone. Weather data was collected on-site at each of the feedyards for correlation to odor …


Characterization Of Volatile Organic Compounds In Bovine Breath Using Solid-Phase Microextraction And Gas Chromatography-Mass Spectrometry, Jacek A. Koziel, Jarett P. Spinhirne, Norbert K. Chirase Jul 2003

Characterization Of Volatile Organic Compounds In Bovine Breath Using Solid-Phase Microextraction And Gas Chromatography-Mass Spectrometry, Jacek A. Koziel, Jarett P. Spinhirne, Norbert K. Chirase

Jacek A. Koziel

A face mask sampling device, DVB/Carboxen/PDMS 50/30 µ m solid phase microextraction (SPME) fibers, and a gas chromatograph with a mass spectrometer detector (GC-MS) were used for sampling and analysis of volatile organic compounds (VOCs) in bovine breath. Breath of 3 morbid steers with respiratory tract infections and 3 healthy steers were sampled 7 times in 19 days for 15 min at each sampling. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Preliminary statistical analyses using Chi-square Test on the frequency of detection of each VOC in each group was performed. …


Characterizing Volatile Fatty Acids And Other Gases In A Rumen Closed In Vitro Fermentation System Using Solid Phase Microextraction, Jarett P. Spinhirne, Jacek A. Koziel, Norbert K. Chirase Jan 2003

Characterizing Volatile Fatty Acids And Other Gases In A Rumen Closed In Vitro Fermentation System Using Solid Phase Microextraction, Jarett P. Spinhirne, Jacek A. Koziel, Norbert K. Chirase

Jacek A. Koziel

A new method for rapid sampling and qualitative characterization of the headspace gases of closed in vitro cultures using solid phase microextraction (SPME) was evaluated for ruminal fluid and ruminal fluid with feed containing a feed additive. Gas sample collection was achieved by exposing a DVB/Carboxen/PDMS 50/30 .m SPME fiber to the headspace of cultures for 1 min every hour. This was followed by immediate analysis on a GC–MS and then reuse of the SPME fiber. Acetic, propionic, isobutyric, butyric, isovaleric, valeric, and hexanoic acids and toluene, dimethyl disulfide, and pentadecane were identified in the headspace. SPME technology facilitated rapid …


Generation And Calibration Of Standard Gas Mixtures For Volatile Fatty Acids Using Permeation Tubes And Solid-Phase Microextraction, Jacek A. Koziel, Jarett P. Spinhirne Jan 2003

Generation And Calibration Of Standard Gas Mixtures For Volatile Fatty Acids Using Permeation Tubes And Solid-Phase Microextraction, Jacek A. Koziel, Jarett P. Spinhirne

Jacek A. Koziel

Volatile fatty acids (VFAs) are major components of odors associated with agricultural operations and livestock housing, solid waste processing and disposal, industrial and municipal wastewater collection, and treatment systems. Emission estimation and assessment of odor control methods depend on reliable air sampling and analysis methods for VFAs. The objective of this research was to develop and test a method for continuous and reliable generation of standard gas mixtures for VFAs based on permeation tubes. Standard gas mixtures for acetic, propionic, isobutyric, butyric, isovaleric, valeric, and hexanoic acids were generated with permeation tubes and monitored for a 100-day period. The gravimetric …