Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 3 of 3
Full-Text Articles in Engineering
Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq
Measurements Of Nh3 Linestrengths And Collisional Broadening Coefficients In N2, O2, Co2, And H2o Near 1103.46 Cm−1, Kyle Owen, Et-Touhami Es-Sebbar, Aamir Farooq
Dr. Et-touhami Es-sebbar
Laser-based ammonia gas sensors have useful applications in many fields including combustion, atmospheric monitoring, and medical diagnostics. Calibration-free trace gas sensors require the spectroscopic parameters including linestrengths and collisional broadening coefficients to be known. Ammonia's strong ν2 vibrational band between View the MathML source has the high absorption strength needed for sensing small concentrations. Within this band, the 1103.46 cm−1 feature is one of the strongest and has minimal interference from CO2 and H2O. However, the six rotational transitions that make up this feature have not been studied previously with absorption spectroscopy due to their small line spacing ranging from …
Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines
Effects Of N2o And O2 Addition To Nitrogen Townsend Dielectric Barrier Discharges At Atmospheric Pressure On The Absolute Ground-State Atomic Nitrogen Density, Et. Es-Sebbar, N. Gherardi, F. Massines
Dr. Et-touhami Es-sebbar
Absolute ground-state density of nitrogen atoms N (2p3 4S3/2) in non-equilibrium Townsend dielectric barrier discharges (TDBDs) at atmospheric pressure sustained in N2/N2O and N2/O2 gas mixtures has been measured using Two-photon absorption laser-induced fluorescence (TALIF) spectroscopy. The quantitative measurements have been obtained by TALIF calibration using krypton as a reference gas. We previously reported that the maximum of N (2p3 4S3/2) atom density is around 3 × 1014 cm−3 in pure nitrogen TDBD, and that this maximum depends strongly on the mean energy dissipated in the gas. In the two gas mixtures studied here, results show that the absolute N …
Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq
Temperature-Dependent Absorption Cross-Section Measurements Of 1-Butene (1-C4h8) In Vuv And Ir, Et-Touhami Es-Sebbar, Yves Benilan, Aamir Farooq
Dr. Et-touhami Es-sebbar
Vacuum ultraviolet (VUV) and infrared (IR) absorption cross-section measurements of 1-butene (1-C4H8; CH2=CHCH2CH3; Butylene) are reported over the temperature range of 296–529 K. The VUV measurements are performed between 115 and 205 nm using synchrotron radiation as a tunable VUV light source. Fourier Transform Infrared (FTIR) spectroscopy is employed to measure absorption cross-section and band strengths in the IR region between 1.54 and 25 μm (∼6500–400 cm−1). The measured room-temperature VUV and IR absorption cross-sections are compared with available literature data and are found to be in good agreement. The oscillator strength for the electronic transition (A1A′→X1A′) around 150–205 nm …