Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Engineering

Development And Preliminary Evaluation Of A Spray Deposition Sensing System For Improving Pesticide Application, Melissa A. Kesterson, Joe D. Luck, Michael P. Sama Dec 2015

Development And Preliminary Evaluation Of A Spray Deposition Sensing System For Improving Pesticide Application, Melissa A. Kesterson, Joe D. Luck, Michael P. Sama

Biosystems and Agricultural Engineering Faculty Publications

An electronic, resistance-based sensor array and data acquisition system was developed to measure spray deposition from hydraulic nozzles. The sensor surface consisted of several parallel tin plated copper traces of varying widths with varying gap widths. The system contained an embedded microprocessor to monitor output voltage corresponding to spray deposition every second. In addition, a wireless module was used to transmit the voltage values to a remote laptop. Tests were conducted in two stages to evaluate the performance of the sensor array in an attempt to quantify the spray deposition. Initial tests utilized manual droplet placement on the sensor surface …


Scalable Control Architecture For Variable-Rate Turn Compensation, Michael P. Sama, Joe D. Luck, Timothy S. Stombaugh May 2015

Scalable Control Architecture For Variable-Rate Turn Compensation, Michael P. Sama, Joe D. Luck, Timothy S. Stombaugh

Biosystems and Agricultural Engineering Faculty Publications

The objective of this study was to determine if a CAN bus could be used to implement variable-rate turn compensation in a manner that is scalable by encoding application rates for an entire implement into a single data message. A variable-rate turn compensation test fixture was developed that used a CAN bus to communicate application rates to 16 individual nodes using a 2-byte data message (80-bit extended identifier CAN messages). The system assumed that the physical structure of an implement was linear and that the control nodes were equally spaced. Application rates for the outer-most nodes were broadcasted and the …


Creating A National Coalition To Address Tractor Overturn Fatalities., Pamela J. Tinc, Paul D. Ayers, John J. May, Mark A. Purschwitz, Julie A. Sorensen Apr 2015

Creating A National Coalition To Address Tractor Overturn Fatalities., Pamela J. Tinc, Paul D. Ayers, John J. May, Mark A. Purschwitz, Julie A. Sorensen

Biosystems and Agricultural Engineering Faculty Publications

Tractor overturns continue to be the leading cause of death on U.S. farms. While rollover protective structures (ROPS) are effective in preventing these fatalities, they are underutilized due to a number of barriers. Past programs in the U.S. and abroad have targeted this area of agricultural safety; however, a national program is not yet in place for U.S. farmers. This study seeks to build a national partnership to address tractor overturn fatalities by increasing the number of tractors with ROPS. A diverse, multisector steering committee has been organized and is working together using Whole System in a Room methods. This …


Pack Factor Measurements For Corn In Grain Storage Bins, Rumela Bhadra, Aaron P. Turner, Mark E. Casada, Michael D. Montross, Sidney A. Thompson, Josephine M. Boac, Samuel G. Mcneill, Ronaldo G. Maghirang Jan 2015

Pack Factor Measurements For Corn In Grain Storage Bins, Rumela Bhadra, Aaron P. Turner, Mark E. Casada, Michael D. Montross, Sidney A. Thompson, Josephine M. Boac, Samuel G. Mcneill, Ronaldo G. Maghirang

Biosystems and Agricultural Engineering Faculty Publications

Shelled yellow corn is commonly stored in concrete or corrugated steel bins. Granular materials compact under their own weight, primarily due to particle rearrangement, leading to an increase in bulk density and a change in volume when stored. Reliable grain pack factors are needed to estimate storage capacities and to accurately monitor grain inventories. A science-based model (WPACKING) of pack factors is available that uses the differential form of Janssen's equation and takes into account the variation in density caused by pressure variation with height and moisture content of the grain and accounts for the effects of grain type, test …


An Optical Sprayer Nozzle Flow Rate Sensor, Joseph S. Dvorak, Luke E. Bryant Jan 2015

An Optical Sprayer Nozzle Flow Rate Sensor, Joseph S. Dvorak, Luke E. Bryant

Biosystems and Agricultural Engineering Faculty Publications

Ensuring proper flow rates from each nozzle on an agricultural sprayer has become even more important as advances continue to be made in precision application technology. In this article, we describe the structure and testing of a sensor technology based on optical cross-correlation to determine the flow rate of individual sprayer nozzles. An advantage of this technology is that it does not require that impellers or other components be placed in the flow, which could cause plugging. The only moving part in the entire system is a solenoid used to inject a tracer dye. The objective of this study was …


Control System Development And Response Analysis Of An Electronically Actuated Variable-Orifice Nozzle For Agricultural Pesticide Applications, Joe D. Luck, Scott A. Shearer, Michael P. Sama, Santosh K. Pitla Jan 2015

Control System Development And Response Analysis Of An Electronically Actuated Variable-Orifice Nozzle For Agricultural Pesticide Applications, Joe D. Luck, Scott A. Shearer, Michael P. Sama, Santosh K. Pitla

Biosystems and Agricultural Engineering Faculty Publications

The goal of this research project was to further the development of an electromechanically controlled variable-orifice nozzle by creating an electronic control system and then evaluating that system based on step and ramp inputs. The control system was developed in a programming environment that combined an electronic data acquisition system and actuator with pressure and flow sensors. A proportional, variable-gain (based on system pressure) control system was developed to adjust nozzle flow rates to meet target application rates. The constraints were to achieve settling time of less than 1.0 s, overshoot of less than 10% of maximum flow (or minimum …


Stored Grain Pack Factors For Wheat: Comparison Of Three Methods To Field Measurements, Josephine M. Boac, Rumela Bhadra, Mark E. Casada, Sidney A. Thompson, Aaron P. Turner, Michael D. Montross, Samuel G. Mcneill, Ronaldo G. Maghirang Jan 2015

Stored Grain Pack Factors For Wheat: Comparison Of Three Methods To Field Measurements, Josephine M. Boac, Rumela Bhadra, Mark E. Casada, Sidney A. Thompson, Aaron P. Turner, Michael D. Montross, Samuel G. Mcneill, Ronaldo G. Maghirang

Biosystems and Agricultural Engineering Faculty Publications

Storing grain in bulk storage units results in grain packing from overbearing pressure, which increases grain bulk density and storage unit capacity. This study compared pack factors of hard red winter (HRW) wheat in vertical storage bins using different methods: the existing packing model (WPACKING), the USDA Risk Management Agency (RMA) method, and the USDA Farm Service Agency Warehouse Licensing and Examination Division (FSA-W) method. Grain bins containing HRW wheat were measured in Kansas, Oklahoma, and Texas. Packing was measured in corrugated steel bins and reinforced concrete bins with diameters ranging from 4.6 to 31.9 m (15.0 to 104.6 ft) …


Flow, Spray Pattern, And Droplet Spectra Characteristics Of An Electronically Actuated Variable-Orifice Nozzle, Joe D. Luck, Santosh K. Pitla, Michael P. Sama, Scott A. Shearer Jan 2015

Flow, Spray Pattern, And Droplet Spectra Characteristics Of An Electronically Actuated Variable-Orifice Nozzle, Joe D. Luck, Santosh K. Pitla, Michael P. Sama, Scott A. Shearer

Biosystems and Agricultural Engineering Faculty Publications

The purpose of this study was to develop and evaluate the flow rate, spray pattern, and droplet spectra characteristics of an actively controlled variable-orifice nozzle at constant carrier pressures. A commercially available variable-orifice nozzle (VariTarget) was modified to allow for direct electromechanical control of the metering stem. The modified system was tested at five carrier pressures ranging from 138 to 414 kPa and five metering stem (and thus orifice) positions. The metering stem position range was chosen because it provided a linear response in flow rate at each carrier pressure. Flow rate testing indicated a turndown ratio of 2.4:1 at …