Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

University of South Florida

2015

Corrosion

Articles 1 - 2 of 2

Full-Text Articles in Engineering

Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner Nov 2015

Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner

USF Tampa Graduate Theses and Dissertations

Recent corrosion related failures of grouted post tensioned tendons, even after the introduction of improved grouts, have led to renewed interest in supplemental or backup means of corrosion control for these systems. A finite element model is presented to explore feasibility of impressed current cathodic protection of strand in grouted tendons. The model examines polarization evolution as function of service time and includes consideration of anode placement and size, grout porosity, pore water alkalinity, electrochemical species diffusivity and applied voltage on the polarization efficacy and durability of such a system. The exploratory model projections suggested that, within the context of …


Metallic Encapsulation For High Temperature (>500 °C) Thermal Energy Storage Applications, Abhinav Bhardwaj Jan 2015

Metallic Encapsulation For High Temperature (>500 °C) Thermal Energy Storage Applications, Abhinav Bhardwaj

USF Tampa Graduate Theses and Dissertations

Deployment of high temperature (>500 °C) thermal energy storage in solar power plants will make solar power more cost competitive and pave the way towards a sustainable future. In this research, a unique metallic encapsulation has been presented for thermal energy storage at high temperatures, capable of operation in aerobic conditions. This goal was achieved by employing low cost materials like carbon steel. The research work presents the unique encapsulation procedure adopted, as well as various coatings evaluated and optimized for corrosion protection. Experimental testing favored the use of 150 μm of nickel on carbon steel for corrosion protection …