Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 1 of 1
Full-Text Articles in Engineering
Correlating Bulk Density (With Dockage) And Test Weight (Without Dockage) For Wheat Samples, Rumela Bhadra, Mark E. Casada, Josephine M. Boac, Aaron P. Turner, Sidney A. Thompson, Michael D. Montross, Ronaldo G. Maghirang, Samuel G. Mcneill
Correlating Bulk Density (With Dockage) And Test Weight (Without Dockage) For Wheat Samples, Rumela Bhadra, Mark E. Casada, Josephine M. Boac, Aaron P. Turner, Sidney A. Thompson, Michael D. Montross, Ronaldo G. Maghirang, Samuel G. Mcneill
Biosystems and Agricultural Engineering Faculty Publications
In grain bins, the compaction of stored grain is caused by the overbearing pressure of the bulk material in the bin. To predict the amount of grain in the bin, compaction values must be determined based on the average bulk density (BD) of the stored material. However, BD is determined following the Federal Grain Inspection Service (FGIS) guidelines for measuring test weight (TW), which require that dockage be removed prior to measuring wheat TW. Thus, this creates a problem for predicting grain compaction and conducting inventory studies, because the average BD of the grain in a bin for these calculations …